Javascript must be enabled to continue!
Numerical Analysis of dew point Indirect Evaporative Cooler
View through CrossRef
An indirect evaporative cooler that uses a Maisotsenko (M) Cycle has the potential to be a green and sustainable solution for managing a building’s cooling demand since it can attain sub-wet bulb temperature without humidification. This study presents the design and simulation analysis of a crossflow indirect evaporative cooler using the COMSOL Multiphysics software for various ambient conditions. The cooler’s performance was evaluated by varying the inlet air temperatures. The analysis was conducted using numerical simulations, and the outcomes were compared with experimental data. The simulation results demonstrated that the cooler could achieve significant temperature reductions at a minor energy consumption as compared to traditional air conditioning systems. This study delivers that this system reduces the temperature of inlet air up to 22°C as well as cooling capacity and coefficient of performance values are 3.699 kW and 27.40. Overall, the results demonstrate the potential of crossflow indirect evaporative coolers as an energy-efficient alternative to conventional air conditioning systems.
Title: Numerical Analysis of dew point Indirect Evaporative Cooler
Description:
An indirect evaporative cooler that uses a Maisotsenko (M) Cycle has the potential to be a green and sustainable solution for managing a building’s cooling demand since it can attain sub-wet bulb temperature without humidification.
This study presents the design and simulation analysis of a crossflow indirect evaporative cooler using the COMSOL Multiphysics software for various ambient conditions.
The cooler’s performance was evaluated by varying the inlet air temperatures.
The analysis was conducted using numerical simulations, and the outcomes were compared with experimental data.
The simulation results demonstrated that the cooler could achieve significant temperature reductions at a minor energy consumption as compared to traditional air conditioning systems.
This study delivers that this system reduces the temperature of inlet air up to 22°C as well as cooling capacity and coefficient of performance values are 3.
699 kW and 27.
40.
Overall, the results demonstrate the potential of crossflow indirect evaporative coolers as an energy-efficient alternative to conventional air conditioning systems.
Related Results
Comparison of the efficiency of solar-powered prototype vapour compression cooler with evaporative charcoal cooler in maintaining quality of French beans
Comparison of the efficiency of solar-powered prototype vapour compression cooler with evaporative charcoal cooler in maintaining quality of French beans
The quality and shelf life of French beans is affected by the time of harvesting and storage period. Cooling immediately after harvesting is important. The use of a solar evaporati...
Physical, Chemical and Biological Characteristics of Dew and Rainwater during the Dry Season of Tropical Islands
Physical, Chemical and Biological Characteristics of Dew and Rainwater during the Dry Season of Tropical Islands
In order to establish data to be used for comparison with future evolution related to climate change, physical, chemical and biological characteristics of dew and rainwater as coll...
Design and Study of Domestic Cooling System through Roof Ventilation Assisted by Evaporative Cooling
Design and Study of Domestic Cooling System through Roof Ventilation Assisted by Evaporative Cooling
This study shows the evaluation of the indirect evaporative cooling system beneath the roof that aims to reduce the cooling load in buildings. As the energy demand for space coolin...
A Study to Explore the Dew Condensation Potential of Cars
A Study to Explore the Dew Condensation Potential of Cars
The metal surfaces of a car exhibit favorable properties for the passive condensation of atmospheric water. Under certain nocturnal climatic conditions (high relative humidity, wea...
Advanced dew-point control system in two-pressure humidity generator to stabilize dew-point generation in low dew-point range
Advanced dew-point control system in two-pressure humidity generator to stabilize dew-point generation in low dew-point range
We developed a novel dew-point control system [advanced dew-point control system (ADCS)] in a primary standard humidity generator based on the two-pressure technique. In the ADCS, ...
Experiment Comparison between Engineering Acid Dew Point and Thermodynamic Acid Dew Point
Experiment Comparison between Engineering Acid Dew Point and Thermodynamic Acid Dew Point
in order to realize the accurate prediction of acid dew point, a set of measurement system of acid dew point for the flue gas flue gas in the tail of the boiler was designed and bu...
Prediction of Dew Point Pressure for High-Pressure Gas Reservoirs Using Artificial Intelligence Techniques
Prediction of Dew Point Pressure for High-Pressure Gas Reservoirs Using Artificial Intelligence Techniques
Abstract
Dew point pressure is a curial parameter in characterizing gas reservoirs. Several methods can be used to determine the dew point pressure, including labora...