Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Absorption Characteristics of Protons and Photons in Tissue

View through CrossRef
This presentation reviews the radiation quality of protons and other energetic ion beams, where radiation quality refers to those relevant physical properties other than the dose of the different types of radiations that can contribute to differences in the absorption characteristics in various tissues and the corresponding clinical outcomes. Prior to initiation of clinical trials with protons, neutrons, pions, and heavy ions, it was generally believed that such particles might have a therapeutic advantage resulting from their greater relative biological effectiveness (RBE). Potential clinical advantages resulting from a greater biological effectiveness, however, have generally been overshadowed during the last three decades by improved controls or reduced complications resulting primarily from the better dose delivery and localization that was possible with these heavier particles in conjunction with improved imaging. The successes both in delivery and in the clinical responses with protons and other light ions resulting from improved dose localization have arguably led the way in stereotactic radiosurgery, intensity modulated radiation therapy, and tomotherapy, stimulating improved methods with conventional radiations as well. Protons or light ions differ significantly in comparison with photon or electron beams in how they interact with the tissue atoms and molecules, and in how they transfer energy to those tissues. Microscopically, the heavier particles tend to travel in straight lines and produce long tracks with the energy concentrated closer to the track of the primary particle, while photons or electrons tend to scatter more easily and produce a more uniform distribution of energy transfers. Because they are hadrons, i.e., nuclear particles, protons and ions are more likely to produce long-range nuclear secondaries with higher masses. This higher concentration of energy associated with the heavier particle beams and the more massive secondaries results in differences in dose localization, clinically and microscopically, and therefore potential differences in short-term and long-term chemical and biological processes. Protons tend to have the least differences in clinical response in comparison with photons and electrons, the radiations used conventionally in therapy, but biological differences have been observed for these particles; it behooves us, therefore, to understand these different mechanisms if we are to take full advantage of their benefits. This article reviews the physical properties of these different particles in terms of microdosimetric distributions of energy deposition in order to compare protons with photons and heavy ions.
Title: Absorption Characteristics of Protons and Photons in Tissue
Description:
This presentation reviews the radiation quality of protons and other energetic ion beams, where radiation quality refers to those relevant physical properties other than the dose of the different types of radiations that can contribute to differences in the absorption characteristics in various tissues and the corresponding clinical outcomes.
Prior to initiation of clinical trials with protons, neutrons, pions, and heavy ions, it was generally believed that such particles might have a therapeutic advantage resulting from their greater relative biological effectiveness (RBE).
Potential clinical advantages resulting from a greater biological effectiveness, however, have generally been overshadowed during the last three decades by improved controls or reduced complications resulting primarily from the better dose delivery and localization that was possible with these heavier particles in conjunction with improved imaging.
The successes both in delivery and in the clinical responses with protons and other light ions resulting from improved dose localization have arguably led the way in stereotactic radiosurgery, intensity modulated radiation therapy, and tomotherapy, stimulating improved methods with conventional radiations as well.
Protons or light ions differ significantly in comparison with photon or electron beams in how they interact with the tissue atoms and molecules, and in how they transfer energy to those tissues.
Microscopically, the heavier particles tend to travel in straight lines and produce long tracks with the energy concentrated closer to the track of the primary particle, while photons or electrons tend to scatter more easily and produce a more uniform distribution of energy transfers.
Because they are hadrons, i.
e.
, nuclear particles, protons and ions are more likely to produce long-range nuclear secondaries with higher masses.
This higher concentration of energy associated with the heavier particle beams and the more massive secondaries results in differences in dose localization, clinically and microscopically, and therefore potential differences in short-term and long-term chemical and biological processes.
Protons tend to have the least differences in clinical response in comparison with photons and electrons, the radiations used conventionally in therapy, but biological differences have been observed for these particles; it behooves us, therefore, to understand these different mechanisms if we are to take full advantage of their benefits.
This article reviews the physical properties of these different particles in terms of microdosimetric distributions of energy deposition in order to compare protons with photons and heavy ions.

Related Results

Multi-photon quantum interference and entanglement
Multi-photon quantum interference and entanglement
Interférence et intrication quantiques à plusieurs photons Dans cette thèse de doctorat, nous étudions des caractéristiques clés du traitement optique de l'informat...
SUMMARY
SUMMARY
SUMMARYThe purpose of the present monograph is to give an account of the distribution of fibrinolytic components in the organism, with special reference to the tissue activator of ...
Radial dependence of ionization losses of protons of the Earth's radiation belts
Radial dependence of ionization losses of protons of the Earth's radiation belts
Abstract. Coulomb losses and charge exchange of protons are considered in detail. On the basis of modern models of the plasmasphere and the exosphere, the radial dependences of the...
GaN detector array for proton therapy
GaN detector array for proton therapy
Imageur GaN pour la proton thérapie Le nitrure de gallium (GaN) est un semi-conducteur à large bande interdite, chimiquement et mécaniquement stable, et technologiq...
Time dilation: A consequence of the speed of light variation
Time dilation: A consequence of the speed of light variation
The escape speed from one point-mass M1 is u1 = (−2u1)½ with u1 (= −M1G/s1) the (Newtonian) gravitational potential energy and s1 the distance between M1 and a chosen point. Obser...
Search for gamma-rays in the EeV sky at the Pierre Auger Observatory using universality
Search for gamma-rays in the EeV sky at the Pierre Auger Observatory using universality
Recherche de photons de très haute énergie à l'Observatoire Pierre Auger en utilisant l'universalité Les rayons cosmiques d’ultra-haute énergie (énergie supérieure ...
Ion velocity distribution functions at a low activity comet
Ion velocity distribution functions at a low activity comet
We study the transition period of induced comet magnetospheres between the simple deflection of the solar wind due to mass loading and a fully developed bow shock. We present exper...
Isolation, characterization and semi-synthesis of natural products dimeric amide alkaloids
Isolation, characterization and semi-synthesis of natural products dimeric amide alkaloids
 Isolation, characterization of natural products dimeric amide alkaloids from roots of the Piper chaba Hunter. The synthesis of these products using intermolecular [4+2] cycloaddit...

Back to Top