Background/Objectives: The aim of our study is to compare the perioperative and functional outcomes of a multimodal approach combining thulium laser vaporization, bipolar TURP, and bipolar plasma vaporization (TLP) with bipolar TURP in a matched-pair analysis. Methods: A nonrandomized, observational, retrospective, and matched-pair analysis was performed on two homogeneous groups of 60 patients who underwent TLP versus bipolar TURP at our center between March 2018 and December 2021. The American Society of Anesthesiologists (ASA) score and prostate volume (PV) were the main parameters used to match patients between the two groups. Follow-up was evaluated at 3, 6, 12, and 24 months after surgery. Results: There was a shorter operative time in favor of TLP (42 versus 45 min, p = 0.402). Median hemoglobin drop (−0.3 versus −0.6, p < 0.001) and median sodium drop (−0.3 versus −0.7, p < 0.001) after surgery were statistically significantly lower in TLP compared to bipolar TURP. The International Prostate Symptom Score (IPSS) and Quality of Life (QoL) scores were significantly lower, and the maximum urinary flow rate was higher in the TLP group. The median PSA decrease 2 years after surgery was 73.92% in the TLP group versus 76.17% in the bipolar TURP group (p = 0.578). The complication rate was lower in the TLP group (20% versus 21.67%, p = 1). Conclusions: The results show that both procedures are equally effective and safe in the treatment of symptomatic BPH with some advantages regarding the TLP technique.
Title: Multimodal Approach Combining Thulium Laser Vaporization, Bipolar Transurethral Resection of the Prostate, and Bipolar Plasma Vaporization versus Bipolar Transurethral Resection of the Prostate: A Matched-Pair Analysis
Description:
Background/Objectives: The aim of our study is to compare the perioperative and functional outcomes of a multimodal approach combining thulium laser vaporization, bipolar TURP, and bipolar plasma vaporization (TLP) with bipolar TURP in a matched-pair analysis.
Methods: A nonrandomized, observational, retrospective, and matched-pair analysis was performed on two homogeneous groups of 60 patients who underwent TLP versus bipolar TURP at our center between March 2018 and December 2021.
The American Society of Anesthesiologists (ASA) score and prostate volume (PV) were the main parameters used to match patients between the two groups.
Follow-up was evaluated at 3, 6, 12, and 24 months after surgery.
Results: There was a shorter operative time in favor of TLP (42 versus 45 min, p = 0.
402).
Median hemoglobin drop (−0.
3 versus −0.
6, p < 0.
001) and median sodium drop (−0.
3 versus −0.
7, p < 0.
001) after surgery were statistically significantly lower in TLP compared to bipolar TURP.
The International Prostate Symptom Score (IPSS) and Quality of Life (QoL) scores were significantly lower, and the maximum urinary flow rate was higher in the TLP group.
The median PSA decrease 2 years after surgery was 73.
92% in the TLP group versus 76.
17% in the bipolar TURP group (p = 0.
578).
The complication rate was lower in the TLP group (20% versus 21.
67%, p = 1).
Conclusions: The results show that both procedures are equally effective and safe in the treatment of symptomatic BPH with some advantages regarding the TLP technique.
Related Results
Thulium: yttrium-aluminiumgarnet laser transurethral vapoenucleation – a new standard in the surgical treatment of large benign prostatic hyperplasia
Thulium: yttrium-aluminiumgarnet laser transurethral vapoenucleation – a new standard in the surgical treatment of large benign prostatic hyperplasia
Introduction. According to the current recommendations of the European Association of Urology and the International Society of Urology, open simple prostatectomy is the reference s...
Long-term results of multimodal treatment of the prostate using the Thulium Laser
Long-term results of multimodal treatment of the prostate using the Thulium Laser
Background and aims. To evaluate a novel multimodal treatment (TLP) that integrates the use of a thulium laser, bipolar transurethral resection of the prostate (TURP), and “button-...
Laser Spectrometric Techniques in Analytical Atomic Spectrometry
Laser Spectrometric Techniques in Analytical Atomic Spectrometry
Abstract
Laser light has a number of spectacular properties that make it useful for analytical spectrometry. One is that it has a high directionality (i.e. i...
Brοadband emitting materials dοped with thulium and hοlmium iοns fοr sοlid-state lasers at 2 μm and beyοnd
Brοadband emitting materials dοped with thulium and hοlmium iοns fοr sοlid-state lasers at 2 μm and beyοnd
Matériaux à large bande d'émission dopés avec des ions thulium et holmium pour des lasers à l'état solide à 2 μm et au-delà.
De nouveaux matériaux inorganiques acti...
Comparison between thulium laser resection of prostate and transurethral plasmakinetic resection of prostate or transurethral resection of prostate
Comparison between thulium laser resection of prostate and transurethral plasmakinetic resection of prostate or transurethral resection of prostate
AbstractBenign prostatic hyperplasia (BPH) is one of the most common diseases in middle-aged and elderly men. In the present study, we aimed to compare the efficacy and safety of t...
Magnetohydrodynamics enhanced radio blackout mitigation system for spacecraft during planetary entries
Magnetohydrodynamics enhanced radio blackout mitigation system for spacecraft during planetary entries
(English) Spacecraft entering planetary atmospheres are enveloped by a plasma layer with high levels of ionization, caused by the extreme temperatures in the shock layer. The charg...
LEO-to-GNSS Laser Interferometer for Space Geodesy with Laser DORIS and Laser SAR
LEO-to-GNSS Laser Interferometer for Space Geodesy with Laser DORIS and Laser SAR
In order to increase the accuracy of precise orbit determination for a single satellite or satellites in LEO formation, we propose using a LEO-to-GNSS laser interferometer, what we...
Thulium Laser energy versus Bipolar current in transurethral enucleation of large prostates; a multicenter prospective randomized study
Thulium Laser energy versus Bipolar current in transurethral enucleation of large prostates; a multicenter prospective randomized study
Abstract
Purpose: Endoscopic enucleation of the prostate (EEP) was introduced to treat patients with large prostate.
The study compared Bipolar current and Thulium laser in...