Javascript must be enabled to continue!
Acceptability and short-term complications of PPIUCD
View through CrossRef
Background: Intrauterine contraceptive device (IUCD) is an effective form of long-acting reversible contraceptive (LARC). Postpartum IUCD insertion is labelled when IUCD is inserted within 10 minutes to 48 hours of expulsion of placenta. assess the acceptability and short-term complications of postpartum intrauterine contraception device insertion in tertiary care hospital of Bangladesh. The aim of the study was to assess the evaluation of factors associated with acceptability of post-partum intrauterine contraceptive device (PPIUCD).
Methods: This was a prospective observational study was conducted at department of obstetrics and gynecology, Dhaka Medical College Hospital (DMCH).
Results: Out of 360 eligible counselled postpartum patients, 48 (13.3%) women underwent PPIUCD insertion. Acceptance of PPIUCD was higher in the age group of 25-30 years (43.75%), having former health counselling about PPIUCD (70.8%), multipara (68.75%). The commonest complications were missing thread (8.3%) followed by lower abdominal pain (6.25%), irregular per vaginal bleeding (4.2%).
Conclusions: PPIUCD is not very acceptable in our set up but it is a safe, highly effective method of contraception with very few side effects and no major complications and contraindications. The acceptability of PPIUCD can be increased with antenatal counselling and institutional delivery.
Title: Acceptability and short-term complications of PPIUCD
Description:
Background: Intrauterine contraceptive device (IUCD) is an effective form of long-acting reversible contraceptive (LARC).
Postpartum IUCD insertion is labelled when IUCD is inserted within 10 minutes to 48 hours of expulsion of placenta.
assess the acceptability and short-term complications of postpartum intrauterine contraception device insertion in tertiary care hospital of Bangladesh.
The aim of the study was to assess the evaluation of factors associated with acceptability of post-partum intrauterine contraceptive device (PPIUCD).
Methods: This was a prospective observational study was conducted at department of obstetrics and gynecology, Dhaka Medical College Hospital (DMCH).
Results: Out of 360 eligible counselled postpartum patients, 48 (13.
3%) women underwent PPIUCD insertion.
Acceptance of PPIUCD was higher in the age group of 25-30 years (43.
75%), having former health counselling about PPIUCD (70.
8%), multipara (68.
75%).
The commonest complications were missing thread (8.
3%) followed by lower abdominal pain (6.
25%), irregular per vaginal bleeding (4.
2%).
Conclusions: PPIUCD is not very acceptable in our set up but it is a safe, highly effective method of contraception with very few side effects and no major complications and contraindications.
The acceptability of PPIUCD can be increased with antenatal counselling and institutional delivery.
Related Results
Evaluation of Short-Term Complications of PPIUCD
Evaluation of Short-Term Complications of PPIUCD
Background: Postpartum intrauterine contraceptives device (PPIUCD) offers an effective means of providing contraceptive services to women in countries with high rates of unmet need...
Acceptance, safety and efficacy of postpartum intrauterine contraceptive device
Acceptance, safety and efficacy of postpartum intrauterine contraceptive device
ABSTRACT
Background:
Postpartum intrauterine contraceptive device (PPIUCD) is safe method of contraception, but with low...
Challenging PPIUCD Removal: A Case of Hysteroscopic Extraction from the Uterine Fundus
Challenging PPIUCD Removal: A Case of Hysteroscopic Extraction from the Uterine Fundus
Intrauterine contraceptive devices offer reliable and reversible contraception. However, there are still challenges that persist in their management, particularly regarding deeply ...
Acceptance of postpartum intrauterine contraceptive device among the parturient and its safety: A prospective analysis from a tertiary care hospital in West Bengal
Acceptance of postpartum intrauterine contraceptive device among the parturient and its safety: A prospective analysis from a tertiary care hospital in West Bengal
Background: The modern intrauterine contraceptive device (IUCD) is a highly effective, safe, private, long-acting, coitus-independent, and rapidly reversible method of contraceptio...
COMPARISON OF COMPLICATIONS OF POST PLACENTAL INSERTION OF INTRAUTERINE DEVICE IN VAGINAL DELIVERY VERSUS CESAREAN SECTION
COMPARISON OF COMPLICATIONS OF POST PLACENTAL INSERTION OF INTRAUTERINE DEVICE IN VAGINAL DELIVERY VERSUS CESAREAN SECTION
Background: The immediate postpartum intrauterine contraceptive device (PPIUCD) offers an effective, reversible contraception method during the delivery process. Recognized for its...
Comparison of Complications of Postpartum Iucd (Ppiucd) Insertion with Interval Iucd Insertion
Comparison of Complications of Postpartum Iucd (Ppiucd) Insertion with Interval Iucd Insertion
Aim: Present study was aimed to compare complications of postpartum IUCD insertion with interval IUCD insertion. Study design: Retrospective study Place and duration: Conducted at...
Postpartum Intrauterine Contraceptive Device (PPIUCD) Versus Interval Intrauterine Contraceptive Device (IUCD) Complications: Which is better?
Postpartum Intrauterine Contraceptive Device (PPIUCD) Versus Interval Intrauterine Contraceptive Device (IUCD) Complications: Which is better?
Introduction: Intrauterine Contraceptive Device (IUCD) is an effective mode of contraception. But its timing of insertion remained debateable. Studies has shown that Postpartum Int...
Comparison of Complication of Postpartum Intrauterine Contraceptive Device With Interval Placed IUCD
Comparison of Complication of Postpartum Intrauterine Contraceptive Device With Interval Placed IUCD
For prevention of unintended and closed interval pregnancies through the first year following childbirth, postpartum family the planning is required. A wide range of reliable and c...

