Javascript must be enabled to continue!
Predictors of delayed pericardial effusion or tamponade after left atrial appendage closure
View through CrossRef
Background: Delayed pericardial effusion or pericardial tamponade
(PE/PT) is a relatively rare complication of left atrial appendage
closure (LAAC) but has serious consequences for affected patients. There
are limited data related to delayed PE/PT. The aim of this study was to
analyze the incidence and potential risks of delayed PE/PT following
LAAC. Methods: Patients with nonvalvular atrial fibrillation who were
successfully implanted with LAAC devices from October 2014 to July 2023
were screened retrospectively. Patients were divided into two groups
according to whether delayed PE/PT occurred. Univariate and multivariate
analyses were used to evaluate the potential risks of delayed PE/PT.
Results: A total of 1866 patients with successfully implanted LAAC
devices were included. Fifty-two patients were excluded because of
missing transesophageal echocardiogram or cardiac CT angiogram data 45
days after the procedure, and 106 patients were excluded because of loss
to follow-up. Thirty-seven patients were excluded because of acute PE/PT
during perioperative period. Among the remaining 1671 patients, 11
developed delayed PE/PT during the follow-up period (2 Watchman2.5, 2
ACP and 7 LAmbre). Ten of these patients recovered after
pericardiocentesis, and one patient required cardiac surgery. Patients
with delayed PE/PT had a larger left atrial appendage (LAA) orifice
diameter, a higher rate of nitinol plug device use and a lower incidence
of systolic heart failure. Univariate and multivariate analyses revealed
that the use of a nitinol plug device was associated with delayed PE/PT
(OR=1.819 95% CI: 0.757-4.343, P=0.018). A larger maximal LAA orifice
diameter was also associated with the occurrence of delayed PE/PT
(OR=1.473 95% CI: 1.163-1.866, P=0.001). Conclusion: Delayed PE/PT is a
rare complication of LAAC device implantation and is related to the use
of a nitinol plug device rather than a nitinol cage device. Patients
with larger LAA orifice diameters are at greater risk of delayed PE/PT
after LAAC.
Title: Predictors of delayed pericardial effusion or tamponade after left atrial appendage closure
Description:
Background: Delayed pericardial effusion or pericardial tamponade
(PE/PT) is a relatively rare complication of left atrial appendage
closure (LAAC) but has serious consequences for affected patients.
There
are limited data related to delayed PE/PT.
The aim of this study was to
analyze the incidence and potential risks of delayed PE/PT following
LAAC.
Methods: Patients with nonvalvular atrial fibrillation who were
successfully implanted with LAAC devices from October 2014 to July 2023
were screened retrospectively.
Patients were divided into two groups
according to whether delayed PE/PT occurred.
Univariate and multivariate
analyses were used to evaluate the potential risks of delayed PE/PT.
Results: A total of 1866 patients with successfully implanted LAAC
devices were included.
Fifty-two patients were excluded because of
missing transesophageal echocardiogram or cardiac CT angiogram data 45
days after the procedure, and 106 patients were excluded because of loss
to follow-up.
Thirty-seven patients were excluded because of acute PE/PT
during perioperative period.
Among the remaining 1671 patients, 11
developed delayed PE/PT during the follow-up period (2 Watchman2.
5, 2
ACP and 7 LAmbre).
Ten of these patients recovered after
pericardiocentesis, and one patient required cardiac surgery.
Patients
with delayed PE/PT had a larger left atrial appendage (LAA) orifice
diameter, a higher rate of nitinol plug device use and a lower incidence
of systolic heart failure.
Univariate and multivariate analyses revealed
that the use of a nitinol plug device was associated with delayed PE/PT
(OR=1.
819 95% CI: 0.
757-4.
343, P=0.
018).
A larger maximal LAA orifice
diameter was also associated with the occurrence of delayed PE/PT
(OR=1.
473 95% CI: 1.
163-1.
866, P=0.
001).
Conclusion: Delayed PE/PT is a
rare complication of LAAC device implantation and is related to the use
of a nitinol plug device rather than a nitinol cage device.
Patients
with larger LAA orifice diameters are at greater risk of delayed PE/PT
after LAAC.
Related Results
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Abstract
Introduction
Immunoglobulin G4-related disease (IgG4-RD) is a recently identified immune-mediated condition that is debilitating and often overlooked. While IgG4-RD has be...
Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract
Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Abstarct
Introduction
Isolated brain hydatid disease (BHD) is an extremely rare form of echinococcosis. A prompt and timely diagnosis is a crucial step in disease management. This ...
274 A FLOATING HEART IN AN EXCAVATED CHEST
274 A FLOATING HEART IN AN EXCAVATED CHEST
Abstract
Pericardial effusion is a common finding in clinical practice either as incidental finding or manifestation of a systemic or cardiac disease. The spectrum o...
Automated Evaluation for Pericardial Effusion and Cardiac Tamponade with Echocardiographic Artificial Intelligence
Automated Evaluation for Pericardial Effusion and Cardiac Tamponade with Echocardiographic Artificial Intelligence
Abstract
Background
Timely and accurate detection of pericardial effusion and assessment cardiac tamponade remain challenging a...
Pericardial effusion and its relationship to age, sex, causes and degrees
Pericardial effusion and its relationship to age, sex, causes and degrees
Abstract
Introduction
Pericardial effusion is one of the most important and dangerous cardiac manifestations that may lead to death. This study aims to study the characteri...
Left atrial appendage anatomy and function: short term response to sustained atrial fibrillation
Left atrial appendage anatomy and function: short term response to sustained atrial fibrillation
OBJECTIVE
To determine whether there is significant atrial or atrial appendage enlargement or functional remodelling as a result of one to two months of sustained...
Pericardial Effusions and Cardiac Tamponade in Hospitalized Systemic Sclerosis Patients: Analysis of the National Inpatient Sample
Pericardial Effusions and Cardiac Tamponade in Hospitalized Systemic Sclerosis Patients: Analysis of the National Inpatient Sample
Abstract
Introduction: Clinically significant pericardial effusions and cardiac tamponade in systemic sclerosis (SSc) patients is uncommon and the factors that contribute t...

