Indications for exchange or explantation of phakic implantable collamer lens with central port in patients with and without keratoconus

View through CrossRef
AIM: To evaluate the causes of phakic implantable collamer lens (ICL) exchange/explantation in patients with and without keratoconus (KC) at two tertiary hospitals in Riyadh, Saudi Arabia. METHODS: A retrospective chart review of all patients who underwent ICL (model V4c with central port) exchange/explantation was performed using the electronic medical record systems. All available preoperative and postoperative data were documented for each patient. RESULTS: Over 7y, 2283 ICL implantation procedures were performed; 46 implants (2%) required exchange (21 implants)/explantation (25 implants), of which 14 cases (30.4%) were patients with KC. Indications for ICL exchange/explantation in non-KC group were vault measurement, cataract formation, increased intraocular pressure, inaccurate refraction, and patient dissatisfaction in 22 (68.75%), 4 (12.5%), 3 (9.37%), 2 (6.25%), and 1 (3.12%) case, respectively. The most common indication for ICL exchange/explantation in the KC group was inaccurate vault sizing in 11 patients (78.57%), inaccurate refraction in 2 patients (14.28%), and patient dissatisfaction postoperatively in 1 (7.14%) case. CONCLUSION: ICL implantation results in predictable refractive outcomes over the long term with exchange/explantation rates comparable to previous literature. Improper vault size is the most common cause of ICL exchange/explantation among patients with or without KC.
Title: Indications for exchange or explantation of phakic implantable collamer lens with central port in patients with and without keratoconus
Description:
AIM: To evaluate the causes of phakic implantable collamer lens (ICL) exchange/explantation in patients with and without keratoconus (KC) at two tertiary hospitals in Riyadh, Saudi Arabia.
METHODS: A retrospective chart review of all patients who underwent ICL (model V4c with central port) exchange/explantation was performed using the electronic medical record systems.
All available preoperative and postoperative data were documented for each patient.
RESULTS: Over 7y, 2283 ICL implantation procedures were performed; 46 implants (2%) required exchange (21 implants)/explantation (25 implants), of which 14 cases (30.
4%) were patients with KC.
Indications for ICL exchange/explantation in non-KC group were vault measurement, cataract formation, increased intraocular pressure, inaccurate refraction, and patient dissatisfaction in 22 (68.
75%), 4 (12.
5%), 3 (9.
37%), 2 (6.
25%), and 1 (3.
12%) case, respectively.
The most common indication for ICL exchange/explantation in the KC group was inaccurate vault sizing in 11 patients (78.
57%), inaccurate refraction in 2 patients (14.
28%), and patient dissatisfaction postoperatively in 1 (7.
14%) case.
CONCLUSION: ICL implantation results in predictable refractive outcomes over the long term with exchange/explantation rates comparable to previous literature.
Improper vault size is the most common cause of ICL exchange/explantation among patients with or without KC.

Related Results

Asthma and Keratoconus: An analysis of the risk factors association with the severity of keratoconus
Asthma and Keratoconus: An analysis of the risk factors association with the severity of keratoconus
Abstract Background: A cross-sectional study was undertaken in Australia to explore a wide range of risk factors associated with keratoconus. A questionnaire addressing age...
Keratoconus: Current perspectives
Keratoconus: Current perspectives
Keratoconus is a corneal thinning disorder in which the inferior paracentral cornea thins and protrudes forwards. The onset is usually during the second decade. Blurred vision and ...
A predictive model for early diagnosis of keratoconus
A predictive model for early diagnosis of keratoconus
Abstract Background: The diagnosis of keratoconus in the early stages of the disease is necessary to initiate an early treatment of keratoconus. Furthermore to avoid possib...
A predictive model for early diagnosis of keratoconus
A predictive model for early diagnosis of keratoconus
Abstract Background: The diagnosis of keratoconus in the early stages of the disease is necessary to initiate an early treatment of keratoconus. Furthermore, to avoid possi...

Back to Top