DECT Numbers in Upper Abdominal Organs for Differential Diagnosis: A Feasibility Study

View through CrossRef
Evaluating the similarity between two entities such as primary and suspected metastatic lesions using quantitative dual-energy computed tomography (DECT) numbers may be useful. However, the criteria for the similarity between two entities based on DECT numbers remain unclear. We therefore considered the possibility that a similarity in DECT numbers within the same organ could provide suitable standards. Thus, we assumed that the variation in DECT numbers within a single organ is sufficiently minimal to be considered clinically equivalent. Therefore, the purpose of this preliminary study is to investigate the differences in DECT numbers within upper abdominal organs. This retrospective study included 30 patients with data from hepatic protocol DECT scans. DECT numbers of the following parameters were collected: (a, b) 70 and 40 keV CT values, (c) slope, (d) effective Z, and (e, f) iodine and water concentration. The agreement of DECT numbers obtained from two regions of interest in the same organ (liver, spleen, and kidney) were assessed using Bland–Altman analysis. The diagnostic ability of each DECT parameter to distinguish between the same or different organs was also assessed using receiver operating characteristic analysis. The 95% limits of agreement within the same organ exhibited the narrowest value range on delayed phase (DP) CT [(c) −11.2–8.3%, (d) −2.0–1.5%, (e) −11.3–8.4%, and (f) −0.59–0.62%]. The diagnostic ability was notably high when using differences in DECT numbers on portal venous (PVP) and DP images (the area under the curve of DP: 0.987–0.999 in (c)–(f)). Using the variability in DECT numbers in the same organ as a criterion for defining similarity may be helpful in making a differential diagnosis by comparing the DECT numbers of two entities.
Title: DECT Numbers in Upper Abdominal Organs for Differential Diagnosis: A Feasibility Study
Description:
Evaluating the similarity between two entities such as primary and suspected metastatic lesions using quantitative dual-energy computed tomography (DECT) numbers may be useful.
However, the criteria for the similarity between two entities based on DECT numbers remain unclear.
We therefore considered the possibility that a similarity in DECT numbers within the same organ could provide suitable standards.
Thus, we assumed that the variation in DECT numbers within a single organ is sufficiently minimal to be considered clinically equivalent.
Therefore, the purpose of this preliminary study is to investigate the differences in DECT numbers within upper abdominal organs.
This retrospective study included 30 patients with data from hepatic protocol DECT scans.
DECT numbers of the following parameters were collected: (a, b) 70 and 40 keV CT values, (c) slope, (d) effective Z, and (e, f) iodine and water concentration.
The agreement of DECT numbers obtained from two regions of interest in the same organ (liver, spleen, and kidney) were assessed using Bland–Altman analysis.
The diagnostic ability of each DECT parameter to distinguish between the same or different organs was also assessed using receiver operating characteristic analysis.
The 95% limits of agreement within the same organ exhibited the narrowest value range on delayed phase (DP) CT [(c) −11.
2–8.
3%, (d) −2.
0–1.
5%, (e) −11.
3–8.
4%, and (f) −0.
59–0.
62%].
The diagnostic ability was notably high when using differences in DECT numbers on portal venous (PVP) and DP images (the area under the curve of DP: 0.
987–0.
999 in (c)–(f)).
Using the variability in DECT numbers in the same organ as a criterion for defining similarity may be helpful in making a differential diagnosis by comparing the DECT numbers of two entities.

Related Results

Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Abstract Introduction Immunoglobulin G4-related disease (IgG4-RD) is a recently identified immune-mediated condition that is debilitating and often overlooked. While IgG4-RD has be...
Evaluation of knee articular cartilage through calcium-suppressed technique in dual-energy computed tomography
Evaluation of knee articular cartilage through calcium-suppressed technique in dual-energy computed tomography
Objectives: The evaluation of knee articular cartilage is of paramount importance in diagnosing and managing musculoskeletal disorders. Accurate and non-invasive imaging techniques...
In Vivo Analysis of Urinary Stones With Dual-Energy Computed Tomography
In Vivo Analysis of Urinary Stones With Dual-Energy Computed Tomography
Objective Formation mechanisms and treatment of the urinary stones are different, depending on their chemical structure. Therefore, determining the stone type plays a k...
Atypical Sigmoid Volvulus in an Adolescent: A Case Report and Literature Review
Atypical Sigmoid Volvulus in an Adolescent: A Case Report and Literature Review
Abstract Introduction Sigmoid volvulus is an underrecognized diagnosis with potentially fatal outcomes in adolescents; the current study aims to present an adolescent with mild sym...
Utility of Dual-Energy CT in Abdominal Interventions
Utility of Dual-Energy CT in Abdominal Interventions
AbstractDual-energy computed tomography (DECT) is an emerging CT technique based on data acquisition at two different settings. Various postprocessing techniques generate different...
Renal Ewing Sarcoma: A Case Report and Literature Review
Renal Ewing Sarcoma: A Case Report and Literature Review
Abstract Introduction Primary renal Ewing sarcoma is an extremely rare and aggressive tumor, representing less than 1% of all renal tumors. This case report contributes valuable in...

Back to Top