Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Femtosecond LASER-Assisted Double Intraocular Lens Exchange in Nanophthalmic Eyes

View through CrossRef
Introduction: Though patients with nanophthalmos frequently endure decreased quality of vision with contact lenses or spectacles, refractive surgery is generally an inadequate alternative due to the associated high refractive error. A refractive lens exchange (RLE) is an alternative option but is technically challenging, requiring accuracy in biometry measurements and procedures. Case Presentation: This case discusses a 27-year-old female with nanophthalmos (axial lengths 17.6 mm and 17.4 mm, right and left eyes, respectively) who underwent a femtosecond laser-assisted (FLA) RLE with simultaneous implantation of a monofocal and a Sulcoflex trifocal (Rayner, Britain) lens in each eye. Preoperative cycloplegic refraction was +11.50/−0.75 × 145 and +12.00/−1.00 × 35 in the RE and LE, respectively. Best-corrected visual acuity (BCVA) at distance and near in the RE and LE was 6/7.5 and J1, 6/8.5 and J2, respectively. Uncorrected visual acuity (UCVA) was >6/120 and >J14 for each eye. FLA RLE was performed in the RE, then in the LE 2 weeks later. In each eye, a monofocal (44.0 D, RE, and LE) and a Sulcoflex trifocal lens (both implants, Rayner, Britain) were implanted in one procedure. Distance and near UCVA measured 6 weeks post-op RE and 1-month post-op LE at 6/8.5 and J1 in the RE, 6/10 and J1 in the LE. The RE and LE refraction and BCVA were +0.50/−1.00 × 115, 6/7.5, and plano/−1.00 × 55, 6/8.5, respectively. The post-op outcomes were uneventful. Conclusion: A single procedure concurrently implanting a monofocal and Sulcoflex trifocal intraocular lens in nanophthalmic eyes resulted in an excellent UCVA. This procedure can be considered esthetic and reconstructive as it significantly improves patient appearance and function.
Title: Femtosecond LASER-Assisted Double Intraocular Lens Exchange in Nanophthalmic Eyes
Description:
Introduction: Though patients with nanophthalmos frequently endure decreased quality of vision with contact lenses or spectacles, refractive surgery is generally an inadequate alternative due to the associated high refractive error.
A refractive lens exchange (RLE) is an alternative option but is technically challenging, requiring accuracy in biometry measurements and procedures.
Case Presentation: This case discusses a 27-year-old female with nanophthalmos (axial lengths 17.
6 mm and 17.
4 mm, right and left eyes, respectively) who underwent a femtosecond laser-assisted (FLA) RLE with simultaneous implantation of a monofocal and a Sulcoflex trifocal (Rayner, Britain) lens in each eye.
Preoperative cycloplegic refraction was +11.
50/−0.
75 × 145 and +12.
00/−1.
00 × 35 in the RE and LE, respectively.
Best-corrected visual acuity (BCVA) at distance and near in the RE and LE was 6/7.
5 and J1, 6/8.
5 and J2, respectively.
Uncorrected visual acuity (UCVA) was >6/120 and >J14 for each eye.
FLA RLE was performed in the RE, then in the LE 2 weeks later.
In each eye, a monofocal (44.
0 D, RE, and LE) and a Sulcoflex trifocal lens (both implants, Rayner, Britain) were implanted in one procedure.
Distance and near UCVA measured 6 weeks post-op RE and 1-month post-op LE at 6/8.
5 and J1 in the RE, 6/10 and J1 in the LE.
The RE and LE refraction and BCVA were +0.
50/−1.
00 × 115, 6/7.
5, and plano/−1.
00 × 55, 6/8.
5, respectively.
The post-op outcomes were uneventful.
Conclusion: A single procedure concurrently implanting a monofocal and Sulcoflex trifocal intraocular lens in nanophthalmic eyes resulted in an excellent UCVA.
This procedure can be considered esthetic and reconstructive as it significantly improves patient appearance and function.

Related Results

Femtosecond laser LenSx–assisted phacoemulsification of mature intumescent cataract
Femtosecond laser LenSx–assisted phacoemulsification of mature intumescent cataract
Background: Phacoemulsification (phaco) of mature intumescent cataract is one of the most difficult to perform anterior eye surgeries. In mature intumescent cataract phaco, the mos...
LEO-to-GNSS Laser Interferometer for Space Geodesy with Laser DORIS and Laser SAR
LEO-to-GNSS Laser Interferometer for Space Geodesy with Laser DORIS and Laser SAR
In order to increase the accuracy of precise orbit determination for a single satellite or satellites in LEO formation, we propose using a LEO-to-GNSS laser interferometer, what we...
Laser Spectrometric Techniques in Analytical Atomic Spectrometry
Laser Spectrometric Techniques in Analytical Atomic Spectrometry
Abstract Laser light has a number of spectacular properties that make it useful for analytical spectrometry. One is that it has a high directionality (i.e. i...
<b>Corneal Biomechanical Integrity After Femtosecond Laser-Assisted Versus Manual Incisions in Cataract Surgery: A Systematic Review</b>
<b>Corneal Biomechanical Integrity After Femtosecond Laser-Assisted Versus Manual Incisions in Cataract Surgery: A Systematic Review</b>
Background: The integrity of the clear corneal incision is fundamental to safety, wound sealing, and refractive stability in cataract surgery. Although femtosecond laser-assisted c...
Theoretical and experimental investigation of femtosecond laser processing fused silica
Theoretical and experimental investigation of femtosecond laser processing fused silica
By tracking the spatiotemporal distribution of the free electron density/temperature and laser intensity, the ablation threshold, depth and crater shape of fused silica for femtose...
Femtosecond Laser-Assisted Cataract Surgery in Pediatric Marfan Syndrome
Femtosecond Laser-Assisted Cataract Surgery in Pediatric Marfan Syndrome
PURPOSE: To report femtosecond laser-assisted cataract surgery in pediatric Marfan syndrome. METHODS: Case report. ...
Evaluating newer generation intraocular lens calculation formulas in manual versus femtosecond laser-assisted cataract surgery
Evaluating newer generation intraocular lens calculation formulas in manual versus femtosecond laser-assisted cataract surgery
AIM: To determine the refractive accuracy of the Haigis, Barrett Universal II (Barrett), and Hill-radial basis function 2.0 (Hill-RBF) intraocular lens (IOL) power calculations for...
Refractive Surgery for Hyperopia
Refractive Surgery for Hyperopia
ABSTRACT PURPOSE: To determine the efficacy, stability, and predictability of refractive surgery for hyperopia using four different procedures: photorefractive keratectom...