Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Testing of a Falling-Film Evaporator for Adsorption Chillers

View through CrossRef
In this work, the performance of an innovative evaporator based on water falling film was investigated. The studied evaporator has been equipped with a recirculation system to maximise the wetted surface. Tests have been carried out in a lab-scale adsorption unit connected to a test bench recently realised at Politecnico di Milano labs for evaluating heat transfer performances under realistic operating conditions. Several ad/desorption cooling cycles were performed, setting different liquid refrigerant initial contents (0.9–1.5 kg), different chilled water inlet temperatures (7–20 °C) and flow rates (200–1000 L/h) and different adsorbent bed temperatures (25–30 °C). Evaporation performance has been determined in delivered cooling capacity. Moreover, the experimental data were used to calculate the overall evaporator heat transfer conductance (UA). Experiments showed how the heat duty peaks are mainly due to the thermal level of the chilled water that enters the evaporator, not the water content inside it because this value only affects the duration of the process. Instead, the UA value does not depend on the evaporator inlet chilled water temperature and initial mass content inside the evaporator. UA is 540–570 W/K for temperatures of chilled water entering the evaporator, equal to 10–20 °C, and mass of refrigerant of 0.9–1.5 kg.
Title: Testing of a Falling-Film Evaporator for Adsorption Chillers
Description:
In this work, the performance of an innovative evaporator based on water falling film was investigated.
The studied evaporator has been equipped with a recirculation system to maximise the wetted surface.
Tests have been carried out in a lab-scale adsorption unit connected to a test bench recently realised at Politecnico di Milano labs for evaluating heat transfer performances under realistic operating conditions.
Several ad/desorption cooling cycles were performed, setting different liquid refrigerant initial contents (0.
9–1.
5 kg), different chilled water inlet temperatures (7–20 °C) and flow rates (200–1000 L/h) and different adsorbent bed temperatures (25–30 °C).
Evaporation performance has been determined in delivered cooling capacity.
Moreover, the experimental data were used to calculate the overall evaporator heat transfer conductance (UA).
Experiments showed how the heat duty peaks are mainly due to the thermal level of the chilled water that enters the evaporator, not the water content inside it because this value only affects the duration of the process.
Instead, the UA value does not depend on the evaporator inlet chilled water temperature and initial mass content inside the evaporator.
UA is 540–570 W/K for temperatures of chilled water entering the evaporator, equal to 10–20 °C, and mass of refrigerant of 0.
9–1.
5 kg.

Related Results

Reclaiming the Wasteland: Samson and Delilah and the Historical Perception and Construction of Indigenous Knowledges in Australian Cinema
Reclaiming the Wasteland: Samson and Delilah and the Historical Perception and Construction of Indigenous Knowledges in Australian Cinema
It was always based on a teenage love story between the two kids. One is a sniffer and one is not. It was designed for Central Australia because we do write these kids off there. N...
Unjuk Kerja Evaporator Pada Mesin Pendingin Dengan Siklus Adsorpsi Menggunakan Energi Surya
Unjuk Kerja Evaporator Pada Mesin Pendingin Dengan Siklus Adsorpsi Menggunakan Energi Surya
Energy needs in Indonesia continue to increase every year. The largest use ofenergy is in the industrial sector, where its needs reach 42.12% of the totalnational energy needs. To ...
A case study on the application of air- and water-cooled oil-free chillers to hospitals in Hong Kong
A case study on the application of air- and water-cooled oil-free chillers to hospitals in Hong Kong
A comparison study on using air-cooled and water-cooled conventional and oil-free chillers in hospitals in Hong Kong is reported. The study commenced with a comprehensive literatur...
Alternative Entrances: Phillip Noyce and Sydney’s Counterculture
Alternative Entrances: Phillip Noyce and Sydney’s Counterculture
Phillip Noyce is one of Australia’s most prominent film makers—a successful feature film director with both iconic Australian narratives and many a Hollywood blockbuster under his ...
Static Analysis of Low Temperature Waste Heat Driven Three-bed Adsorption Chillers Potential for Building Cooling Application
Static Analysis of Low Temperature Waste Heat Driven Three-bed Adsorption Chillers Potential for Building Cooling Application
The adsorption cooling system is an environmentally friendly system because of non-CFCs (chlorofluorocarbons) and non-HCFCs (hydrochlorofluorocarbons). The simulation developed is ...
Optimization strategies for absorption chillers: A performance study on natural gas and LPG utilization
Optimization strategies for absorption chillers: A performance study on natural gas and LPG utilization
This research aims to investigate optimization strategies for absorption chillers utilizing natural gas and liquefied petroleum gas (LPG) to enhance performance and efficiency. The...
The effect of fear of falling towards falls incidence among knee osteoarthritis patients in Malang, Indonesia: a cross-sectional study
The effect of fear of falling towards falls incidence among knee osteoarthritis patients in Malang, Indonesia: a cross-sectional study
Introduction: One serious effect of knee osteoarthritis (OA) is falling. Some predictors caused its vulnerability, one of which was fear of falling. However, few studies investigat...
Effect of co-existing parameters on the adsorption of perfluorooctanoic acid (PFOA) on powdered activated charcoal
Effect of co-existing parameters on the adsorption of perfluorooctanoic acid (PFOA) on powdered activated charcoal
In this study the adsorption of PFOA on three different commercial Powdered Activated Charcoal (PACs), wood-based, bamboo-based and coconut-shell-based activated charcoals, was exp...

Back to Top