Distributed Thermal Response Tests Using a Heating Cable and Fiber Optic Temperature Sensing
View through CrossRef
Thermal response tests are used to assess the subsurface thermal conductivity to design ground-coupled heat pump systems. Conventional tests are cumbersome and require a source of high power to heat water circulating in a pilot ground heat exchanger. An alternative test method using heating cable was verified in the field as an option to conduct this heat injection experiment with a low power source and a compact equipment. Two thermal response tests using heating cable sections and a continuous heating cable were performed in two experimental heat exchangers on different sites in Canada and France. The temperature evolution during the tests was monitored using submersible sensors and fiber optic distributed temperature sensing. Free convection that can occur in the pipe of the heat exchanger was evaluated using the Rayleigh number stability criterion. The finite and infinite line source equations were used to reproduce temperature variations along the heating cable sections and continuous heating cable, respectively. The thermal conductivity profile of each site was inferred and the uncertainly of the test was evaluated. A mean thermal conductivity 15% higher than that revealed with the conventional test was estimated with heating cable sections. The thermal conductivity evaluated using the continuous heating cable corresponds to the value estimated during the conventional test. The average uncertainly associated with the heating cable section test was 15.18%, while an uncertainty of 2.14% was estimated for the test with the continuous heating cable. According to the Rayleigh number stability criterion, significant free convection can occur during the heat injection period when heating cable sections are used. The continuous heating cable with a low power source is a promising method to perform thermal response tests and further tests could be carried out in deep boreholes to verify its applicability.
Title: Distributed Thermal Response Tests Using a Heating Cable and Fiber Optic Temperature Sensing
Description:
Thermal response tests are used to assess the subsurface thermal conductivity to design ground-coupled heat pump systems.
Conventional tests are cumbersome and require a source of high power to heat water circulating in a pilot ground heat exchanger.
An alternative test method using heating cable was verified in the field as an option to conduct this heat injection experiment with a low power source and a compact equipment.
Two thermal response tests using heating cable sections and a continuous heating cable were performed in two experimental heat exchangers on different sites in Canada and France.
The temperature evolution during the tests was monitored using submersible sensors and fiber optic distributed temperature sensing.
Free convection that can occur in the pipe of the heat exchanger was evaluated using the Rayleigh number stability criterion.
The finite and infinite line source equations were used to reproduce temperature variations along the heating cable sections and continuous heating cable, respectively.
The thermal conductivity profile of each site was inferred and the uncertainly of the test was evaluated.
A mean thermal conductivity 15% higher than that revealed with the conventional test was estimated with heating cable sections.
The thermal conductivity evaluated using the continuous heating cable corresponds to the value estimated during the conventional test.
The average uncertainly associated with the heating cable section test was 15.
18%, while an uncertainty of 2.
14% was estimated for the test with the continuous heating cable.
According to the Rayleigh number stability criterion, significant free convection can occur during the heat injection period when heating cable sections are used.
The continuous heating cable with a low power source is a promising method to perform thermal response tests and further tests could be carried out in deep boreholes to verify its applicability.
Related Results
Thermal Effects in High Compactness CEA Stack
Thermal Effects in High Compactness CEA Stack
Thermal management is a pivotal aspect of stack durability and system operability. Consequently, understanding the thermal mapping within a stack based on its operating conditions ...
Application of Optical Sensors in Deepwater Environments
Application of Optical Sensors in Deepwater Environments
Abstract
Fiber optic sensors are currently being deployed in novel completions throughout the world. The first completions being targeted are wells where specific...
INFLUENCE OF THE AMBIENT TEMPERATURE ON THE MECHANICAL TENSION OF THE OPTICAL CABLE
INFLUENCE OF THE AMBIENT TEMPERATURE ON THE MECHANICAL TENSION OF THE OPTICAL CABLE
To ensure the quality and reliability of the fiber-optic communication line during the exploitation, it is necessary to constantly monitor the technical condition of the optical ca...
Neuritis optik idiopatik dengan penyerta central serous chorioretinopathy sebagai manifestasi chronic relapsing inflammatory optic neuropathy: Sebuah laporan kasus
Neuritis optik idiopatik dengan penyerta central serous chorioretinopathy sebagai manifestasi chronic relapsing inflammatory optic neuropathy: Sebuah laporan kasus
Introduction: Idiopathic optic neuritis is an optic neuropathy with characteristics of optic nerve dysfunction that can be caused by various disorders of the optic nerve, including...
Subsea Environmental Sensing with Operational Submarine Cables
Subsea Environmental Sensing with Operational Submarine Cables
I present the results of the Suboptic working group formed during the Suboptic 2023 conference to create a synergy between submarine cable owners and government institutions to imp...
Comparison of Single-channel and Split-window Methods for Estimating Land Surface Temperature from Landsat 8 Data
Comparison of Single-channel and Split-window Methods for Estimating Land Surface Temperature from Landsat 8 Data
Abstract: Landsat 8 is the eighth satellite in the Landsat program, which provides images at 11 spectral channels, including 2 thermal infrared bands at a spatial resolution of 100...
A Comparative Analysis of Conventional ESP and Fiber-Optic Distributed Sensing (DTS/DAS)
A Comparative Analysis of Conventional ESP and Fiber-Optic Distributed Sensing (DTS/DAS)
Abstract
This paper compares traditional Electric Submersible Pump (ESP) downhole sensors with fiber-optic distributed sensing technologies (Distributed Temperatu...
Fiber Optic Downhole Sensors for Subsea Wells: Remaining Problems
Fiber Optic Downhole Sensors for Subsea Wells: Remaining Problems
Abstract
Fibreoptic sensors are being increasingly used in wells with dry wellheads. However, for subsea wells some challenges remain to be overcome. These are e....