Determination of Ultimate Load and Stability Evaluation of Transmission Tower Foundation during Operation Period

View through CrossRef
Abstract 500kV transmission tower foundation on the Yanzi landslide is taken as the research object this article. The extreme working conditions of the transmission tower foundation under different operating conditions, including maximum wind speed, icing and disconnection, are determined. Based on this, the stability of the tower foundation, including foundation uplift stability, foundation overturning stability, foundation bearing capacity, is initially evaluated according to the " Code for Design of 110kV ∼ 750kV Overhead Transmission Line " (GB 50545-2010). The results show that when the wind speed is greater than 20m/s, the maximum wind speed is determined as the extreme load condition of the tower foundation. Preliminary evaluation of the stability of the tower foundation shows that its stability is related to the wind speed and the buried depth of the tower foundation. Therefore, the research results can provide technical reference for related power departments.
Title: Determination of Ultimate Load and Stability Evaluation of Transmission Tower Foundation during Operation Period
Description:
Abstract 500kV transmission tower foundation on the Yanzi landslide is taken as the research object this article.
The extreme working conditions of the transmission tower foundation under different operating conditions, including maximum wind speed, icing and disconnection, are determined.
Based on this, the stability of the tower foundation, including foundation uplift stability, foundation overturning stability, foundation bearing capacity, is initially evaluated according to the " Code for Design of 110kV ∼ 750kV Overhead Transmission Line " (GB 50545-2010).
The results show that when the wind speed is greater than 20m/s, the maximum wind speed is determined as the extreme load condition of the tower foundation.
Preliminary evaluation of the stability of the tower foundation shows that its stability is related to the wind speed and the buried depth of the tower foundation.
Therefore, the research results can provide technical reference for related power departments.

Related Results

Numerical Simulation of Impact Effect on Stability of Transmission Tower Foundation
Numerical Simulation of Impact Effect on Stability of Transmission Tower Foundation
The impact effect can cause structural damage to a transmission tower’s foundation and affect its overall stability. In order to study the influence of the impact effect on the sta...
Influence of the Flexible Tower on Aeroelastic Loads of the Wind Turbine
Influence of the Flexible Tower on Aeroelastic Loads of the Wind Turbine
Based on the two-node Euler-Bernoulli beam, the tower system is discretized by finite element method, and the cubic Hermite polynomial is taken as the shape function of the beam el...
Crane Load Moment System For Offshore Crane Operations
Crane Load Moment System For Offshore Crane Operations
Abstract History has shown that dependency upon the crane operator to monitor loads and boom angle or load radius do not allow the margin necessary to perform the...
Parametric Design of Scroll-shaped Pylon of Single Tower Cable-stayed Bridge
Parametric Design of Scroll-shaped Pylon of Single Tower Cable-stayed Bridge
Using single-tower cable-stayed bridge as example, this article introduces the design and construction process of a cable-stayed bridge with a scroll-shaped tower, as well as the o...
Non-Martial and Martial Methods to an Ultimate Political Goal of the Tiger Movement in Sri Lanka
Non-Martial and Martial Methods to an Ultimate Political Goal of the Tiger Movement in Sri Lanka
The Tiger Movement had one ultimate political goal, and two main alternating methods to reach this goal, which was to obtain recognition by world community for the right of self-de...
Edge strength of core drilled and waterjet cut holes in architectural glass
Edge strength of core drilled and waterjet cut holes in architectural glass
AbstractIn structural glass design, an often-applied connection is a bolted connection subjected to in-plane tensile loads. Traditionally, the hole in the glass pane is manufacture...
The influence of excavation of combined foundations of high-voltage transmission towers and spoils loading on landslide stability
The influence of excavation of combined foundations of high-voltage transmission towers and spoils loading on landslide stability
Abstract With the construction of “West-to-East Power Transmission” and national networked engineering projects, high-voltage transmission towers, which are importan...