A Miniature Four-Channel Ion Trap Array Based on Non-silicon MEMS Technology
View through CrossRef
With the increasing application field, a higher requirement is put forward for the mass spectrometer. The reduction in size will inevitably cause a loss of precision; therefore, it is necessary to develop a high-performance miniature mass spectrometer. Based on the researches of rectangular ion trap, the relationship between mass resolution and structural parameters of the ion trap array was analyzed by further simulation. The results indicate that, considering the balance of mass resolution and extraction efficiency, the preferable values for the field radius of exit direction y0 and ion exit slot width s0 are 1.61 mm and 200 μm, respectively. Afterwards, a miniature four-channel ion trap array (MFITA) was fabricated, by using MEMS and laser etching technology, and mass spectrometry experiments were carried out to demonstrate its performance. The mass resolution of butyl diacetate with m/z = 230 can reach 324. In addition, the consistency of four channels is verified within the error tolerance, by analyzing air samples. Our work can prove the correctness of the structural design and the feasibility of MEMS preparation for MFITA, which will bring meaningful guidance for its future development and optimization.
Title: A Miniature Four-Channel Ion Trap Array Based on Non-silicon MEMS Technology
Description:
With the increasing application field, a higher requirement is put forward for the mass spectrometer.
The reduction in size will inevitably cause a loss of precision; therefore, it is necessary to develop a high-performance miniature mass spectrometer.
Based on the researches of rectangular ion trap, the relationship between mass resolution and structural parameters of the ion trap array was analyzed by further simulation.
The results indicate that, considering the balance of mass resolution and extraction efficiency, the preferable values for the field radius of exit direction y0 and ion exit slot width s0 are 1.
61 mm and 200 μm, respectively.
Afterwards, a miniature four-channel ion trap array (MFITA) was fabricated, by using MEMS and laser etching technology, and mass spectrometry experiments were carried out to demonstrate its performance.
The mass resolution of butyl diacetate with m/z = 230 can reach 324.
In addition, the consistency of four channels is verified within the error tolerance, by analyzing air samples.
Our work can prove the correctness of the structural design and the feasibility of MEMS preparation for MFITA, which will bring meaningful guidance for its future development and optimization.
Related Results
Optimization and simulation of MEMS rectilinear ion trap
Optimization and simulation of MEMS rectilinear ion trap
In this paper, the design of a MEMS rectilinear ion trap was optimized under simulated conditions. The size range of the MEMS rectilinear ion trap’s electrodes studied in this pape...
(Invited) A 1-mG MEMS Sensor
(Invited) A 1-mG MEMS Sensor
MEMS (microelectromechanical systems) technology has contributed substantially to the miniaturization of inertial sensors, such as accelerometers and gyroscopes [1]. Nowadays, MEMS...
En skvatmølle i Ljørring
En skvatmølle i Ljørring
A Horizontal Mill at Ljørring, Jutland.Horizontal water-mills have been in use in Jutland since the beginning of the Christian era 2). But the one here described shows so close a c...
Violin miniature in creativity by Liudmila Shukailo: features of the genre interpretation
Violin miniature in creativity by Liudmila Shukailo: features of the genre interpretation
Background. Rapidness of information flows of contemporary life enforces to concentrate a significant amount of information in small formats. This fact meaningfully increases socia...
RELIABILITY OF MEMS ACCELEROMETERS FOR INSTRUMENTAL INTENSITY MAPPING OF EARTHQUAKES
RELIABILITY OF MEMS ACCELEROMETERS FOR INSTRUMENTAL INTENSITY MAPPING OF EARTHQUAKES
This work investigates suitability of low cost Micro-Electro Mechanical System (MEMS) sensors in strong motion related studies, particularly in shaking intensity networks. Two type...
A MEMS IMU De-Noising Method Using Long Short Term Memory Recurrent Neural Networks (LSTM-RNN)
A MEMS IMU De-Noising Method Using Long Short Term Memory Recurrent Neural Networks (LSTM-RNN)
Microelectromechanical Systems (MEMS) Inertial Measurement Unit (IMU) containing a three-orthogonal gyroscope and three-orthogonal accelerometer has been widely utilized in positio...
Otomatisasi Flame Trap Berbasis Sistem Pneumatik Pada Kendaraan Pengangkut BBM
Otomatisasi Flame Trap Berbasis Sistem Pneumatik Pada Kendaraan Pengangkut BBM
Abstrak - Flame trap merupakan sebuah perangkat yang dipasang pada knalpot mobil tangki bahan bakar minyak (BBM) dengan bertujuan untuk mencegah terjadinya percikan api yang ditimb...
Diels–Alder reactions of mass‐selected ions in an ion trap mass spectrometer
Diels–Alder reactions of mass‐selected ions in an ion trap mass spectrometer
AbstractThis Communication describes the use of a bench‐top ion trap mass spectrometer for the study of structurally diagnostic ion/molecule reactions. The power of the experiment ...