Javascript must be enabled to continue!
Blast Loading Response of Reinforced Concrete Panels Externally Reinforced with Steel Strips
View through CrossRef
Frequent terrorist activities, the use of vehicle bomb blasts and improvised explosive devices (IEDs) have brought forth the task of protection against blasts as a priority issue for engineers. Terrorists mostly target the areas where human and economic losses are significantly higher. It is really challenging to study the effects of blast loading on structures due to numerous variables. For instance, the type of detonation charge, explosive material, placement of charge and standoff distance, etc., are a few of the variables which make the system more complicated. Reinforced cement concrete (RCC) wall panels are commonly used for protecting important installations and buildings. In this research, the response of RCC wall panels has been investigated due to the blast effect caused by two TNT charge weights of 50 kg and 100 kg. These two charge weights have been selected after a detailed study of terrorist activities in the recent past. For this purpose, an existing arrangement at an important military installation, i.e., NESCOM Hospital Islamabad in Pakistan, has been selected. To reduce computational efforts, three RCC wall panels, placed side by side producing a continuous front along with a corresponding boundary and structural wall, have been considered. RCC wall panels are placed at a distance of 3 ft from the perimeter of the boundary wall and 23 ft from the structural wall. The displacement on the front face of RCC wall panels and the structural wall is measured at three levels of top, middle and bottom. ANSYS AUTODYN software has been used to simulate the model. Analysis has been carried out to identify and study the weakness of existing arrangements. Literature was reviewed for suggesting an appropriate strengthening technique for existing structures against blast loading. It was found that in addition to existing strengthening techniques, use of steel strips is amongst the most feasible technique for strengthening existing structures. It not only significantly enhanced the blast performance of structures, but it also significantly reduced z-direction displacements and pressures. The results show that the use of steel strips as the improvement technique for already placed RCC wall panels can be effective against a blast loading of up to 100 kg TNT.
Title: Blast Loading Response of Reinforced Concrete Panels Externally Reinforced with Steel Strips
Description:
Frequent terrorist activities, the use of vehicle bomb blasts and improvised explosive devices (IEDs) have brought forth the task of protection against blasts as a priority issue for engineers.
Terrorists mostly target the areas where human and economic losses are significantly higher.
It is really challenging to study the effects of blast loading on structures due to numerous variables.
For instance, the type of detonation charge, explosive material, placement of charge and standoff distance, etc.
, are a few of the variables which make the system more complicated.
Reinforced cement concrete (RCC) wall panels are commonly used for protecting important installations and buildings.
In this research, the response of RCC wall panels has been investigated due to the blast effect caused by two TNT charge weights of 50 kg and 100 kg.
These two charge weights have been selected after a detailed study of terrorist activities in the recent past.
For this purpose, an existing arrangement at an important military installation, i.
e.
, NESCOM Hospital Islamabad in Pakistan, has been selected.
To reduce computational efforts, three RCC wall panels, placed side by side producing a continuous front along with a corresponding boundary and structural wall, have been considered.
RCC wall panels are placed at a distance of 3 ft from the perimeter of the boundary wall and 23 ft from the structural wall.
The displacement on the front face of RCC wall panels and the structural wall is measured at three levels of top, middle and bottom.
ANSYS AUTODYN software has been used to simulate the model.
Analysis has been carried out to identify and study the weakness of existing arrangements.
Literature was reviewed for suggesting an appropriate strengthening technique for existing structures against blast loading.
It was found that in addition to existing strengthening techniques, use of steel strips is amongst the most feasible technique for strengthening existing structures.
It not only significantly enhanced the blast performance of structures, but it also significantly reduced z-direction displacements and pressures.
The results show that the use of steel strips as the improvement technique for already placed RCC wall panels can be effective against a blast loading of up to 100 kg TNT.
Related Results
Performance of the laminated glass systems under static and blast pressure loading
Performance of the laminated glass systems under static and blast pressure loading
[ACCESS RESTRICTED TO THE UNIVERSITY OF MISSOURI AT AUTHOR'S REQUEST.] The increase of explosions threats toward civilian targets has raised concerns about a building's safety. Lam...
Dynamic response of curved laminated glass panels
Dynamic response of curved laminated glass panels
Extreme events, such as blasts, pose a severe threat to a building's structural integrity. The building envelope serves as the primary defense against external explosions, with bla...
Peak Particle Velocity for Blasting Rock Modeling
Peak Particle Velocity for Blasting Rock Modeling
ABSTRACT
Blasting mechanisms are a complex coupling of the rock mass properties and the explosive detonation performance as well as the blast design parameters. B...
He found use for reinforced concrete where, it would seem, this material has no place
He found use for reinforced concrete where, it would seem, this material has no place
Introduction. The article is devoted to an employee of the Research Institute of Reinforced Concrete, Doctor of Technical Sciences, Professor I.G. Ludkovsky, a specialist in the fi...
Structural Behavior And Design Method Of Steel/Concrete Composite Ice Walls for Arctic Offshore Structures
Structural Behavior And Design Method Of Steel/Concrete Composite Ice Walls for Arctic Offshore Structures
ABSTRACT
In order to develop an optimum steel/concrete composite ice wall for the arctic offshore structures, structural behavior of the steel/concrete composite ...
Numerical simulation of progressive collapse of structures under blast loads
Numerical simulation of progressive collapse of structures under blast loads
The growing need for blast-resistant designs in structural engineering is driven by the rising threat of terrorism, accidental explosions, and the significant risk of progressive c...
Study on the effect of seawater on making and curing of unreinforced concrete applications
Study on the effect of seawater on making and curing of unreinforced concrete applications
Concrete, an essential component of worldwide infrastructure, depends significantly on fresh water for its manufacturing, contributing to freshwater scarcity in many regions. As co...
Identification of novel rice blast resistance alleles through sequence-based allele mining
Identification of novel rice blast resistance alleles through sequence-based allele mining
Abstract
Background: As rice ( Oryza sativa ) is the staple food of more than half the world’s population, rice production contributes greatly to global food security. Rice...

