<b><i>Background:</i></b> Axillary venous access is preferred for CIED implantation. The procedure is usually performed under fluoroscopic guidance in anteroposterior (A-P) view. However, there is a lack of perception of depth in this view with a fear of creating complications. Caudal fluoroscopy (adding 30°–35° caudal angulation to A-P projection) has been proposed to circumvent this problem. <b><i>Objective:</i></b> The aim of this study was to elucidate the advantages of caudal fluoroscopy using fluoroscopic images, contrast venograms, and CT angiography images of axillary vein. <b><i>Methods:</i></b> The fluoroscopic images and contrast venograms obtained in the A-P view were compared with caudal fluoroscopy in patients undergoing CIED implantation at our centre. Also, the CT angiography images of axillary vein were reconstructed to understand the relative anatomy of the vein and the underlying lung parenchyma, simulating these 2 projections. <b><i>Results:</i></b> The CT angiography images, contrast venograms, and fluoroscopic images confirmed that caudal fluoroscopy allows better visualization of the vein in relation to the lung parenchyma and rib cage. Analysis of fluoroscopic images revealed that the bend of the first rib formed a conical prominence in caudal fluoroscopy. This served as an important bony landmark for successful venous access, which was usually obtained while the needle was being directed towards this prominence in caudal fluoroscopy. <b><i>Conclusions:</i></b> The proposed advantages of caudal fluoroscopy for CIED implantation have been elucidated by analysis of CT angiography images, contrast venograms, and fluoroscopic images.
Title: Utility of Caudal Angulation for Venous Access under Fluoroscopic Guidance during Cardiovascular Implantable Electronic Device Implantation
Description:
<b><i>Background:</i></b> Axillary venous access is preferred for CIED implantation.
The procedure is usually performed under fluoroscopic guidance in anteroposterior (A-P) view.
However, there is a lack of perception of depth in this view with a fear of creating complications.
Caudal fluoroscopy (adding 30°–35° caudal angulation to A-P projection) has been proposed to circumvent this problem.
<b><i>Objective:</i></b> The aim of this study was to elucidate the advantages of caudal fluoroscopy using fluoroscopic images, contrast venograms, and CT angiography images of axillary vein.
<b><i>Methods:</i></b> The fluoroscopic images and contrast venograms obtained in the A-P view were compared with caudal fluoroscopy in patients undergoing CIED implantation at our centre.
Also, the CT angiography images of axillary vein were reconstructed to understand the relative anatomy of the vein and the underlying lung parenchyma, simulating these 2 projections.
<b><i>Results:</i></b> The CT angiography images, contrast venograms, and fluoroscopic images confirmed that caudal fluoroscopy allows better visualization of the vein in relation to the lung parenchyma and rib cage.
Analysis of fluoroscopic images revealed that the bend of the first rib formed a conical prominence in caudal fluoroscopy.
This served as an important bony landmark for successful venous access, which was usually obtained while the needle was being directed towards this prominence in caudal fluoroscopy.
<b><i>Conclusions:</i></b> The proposed advantages of caudal fluoroscopy for CIED implantation have been elucidated by analysis of CT angiography images, contrast venograms, and fluoroscopic images.
Related Results
Water-soluble contrast agent during swallowing study increases aspiration sensitivity and antedates oral feeding without respiratory and drug complications: a prospective, observational, case-control Trial v1
Water-soluble contrast agent during swallowing study increases aspiration sensitivity and antedates oral feeding without respiratory and drug complications: a prospective, observational, case-control Trial v1
Water-soluble contrast agent during swallowing study increases aspiration sensitivity and antedates oral feeding without respiratory and drug complications: a prospective, observat...
Urrets-Zavalia syndrome following implantable collamer lens (ICL) implantation: a case report and review of the literature
Urrets-Zavalia syndrome following implantable collamer lens (ICL) implantation: a case report and review of the literature
Abstract
Background
Urrets-Zavalia syndrome is a condition that arises after eye surgery, often linked to increased intraocular pressure followin...
Major complications of caudal block: a prospective survey of 973 cases in adult anorectal surgery
Major complications of caudal block: a prospective survey of 973 cases in adult anorectal surgery
Abstract
Background: We conducted a prospective study of surgical inpatients at a teaching hospital to assess the incidence and potential risk factors for major complicatio...
Retinitis Pigmentosa
Retinitis Pigmentosa
In studying the cases with typical and atypical pigmentary degeneration of the retina we strived to analyse in the clinical material all ophthalmoscopic and ocular changes together...
European Section of Urotechnology educational video on fluoroscopic‐guided puncture in percutaneous nephrolithotomy: all techniques step by step
European Section of Urotechnology educational video on fluoroscopic‐guided puncture in percutaneous nephrolithotomy: all techniques step by step
Objective
To describe the most common fluoroscopic‐guided access techniques during percutaneous nephrolithotomy (PCNL) in a step‐by‐step manner and to assist in...
Evolution of the caudal vertebral series in macronarian sauropod dinosaurs
Evolution of the caudal vertebral series in macronarian sauropod dinosaurs
Macronaria is one of the most abundant and most widely accepted phylogenetic sauropod group. One of the most common preserved parts are the caudal vertebrae which displayed enough ...
Nerve stimulation guided bilateral pudendal nerve block versus landmark-based caudal block for hypospadias repair in young children: a prospective, randomized, pragmatic trial
Nerve stimulation guided bilateral pudendal nerve block versus landmark-based caudal block for hypospadias repair in young children: a prospective, randomized, pragmatic trial
Introduction
Caudal block is frequently performed to provide analgesia for hypospadias repair. Literature suggests that pudendal block provides prolonged postoper...
Improved Measurement of Vascular Access Pressure
Improved Measurement of Vascular Access Pressure
Vascular access stenosis and thrombosis is one of the key problems for hemodialysis patients. Prospective monitoring of static venous dialysis pressures can be applied to detect ou...