Javascript must be enabled to continue!
Ultrasonic locating devices for central venous cannulation: meta-analysis
View through CrossRef
Abstract
Objectives
To assess the evidence for the clinical effectiveness of ultrasound guided central venous cannulation.
Data sources
15 electronic bibliographic databases, covering biomedical, science, social science, health economics, and grey literature.
Design
Systematic review and meta-analysis of randomised controlled trials.
Populations
Patients scheduled for central venous access.
Intervention reviewed
Guidance using real time two dimensional ultrasonography or Doppler needles and probes compared with the anatomical landmark method of cannulation.
Data extraction
Risk of failed catheter placement (primary outcome), risk of complications from placement, risk of failure on first attempt at placement, number of attempts to successful catheterisation, and time (seconds) to successful catheterisation.
Data synthesis
18 trials (1646 participants) were identified. Compared with the landmark method, real time two dimensional ultrasound guidance for cannulating the internal jugular vein in adults was associated with a significantly lower failure rate both overall (relative risk 0.14, 95% confidence interval 0.06 to 0.33) and on the first attempt (0.59, 0.39 to 0.88). Limited evidence favoured two dimensional ultrasound guidance for subclavian vein and femoral vein procedures in adults (0.14, 0.04 to 0.57 and 0.29, 0.07 to 1.21, respectively). Three studies in infants confirmed a higher success rate with two dimensional ultrasonography for internal jugular procedures (0.15, 0.03 to 0.64). Doppler guided cannulation of the internal jugular vein in adults was more successful than the landmark method (0.39, 0.17 to 0.92), but the landmark method was more successful for subclavian vein procedures (1.48, 1.03 to 2.14). No significant difference was found between these techniques for cannulation of the internal jugular vein in infants. An indirect comparison of relative risks suggested that two dimensional ultrasonography would be more successful than Doppler guidance for subclavian vein procedures in adults (0.09, 0.02 to 0.38).
Conclusions
Evidence supports the use of two dimensional ultrasonography for central venous cannulation.
Title: Ultrasonic locating devices for central venous cannulation: meta-analysis
Description:
Abstract
Objectives
To assess the evidence for the clinical effectiveness of ultrasound guided central venous cannulation.
Data sources
15 electronic bibliographic databases, covering biomedical, science, social science, health economics, and grey literature.
Design
Systematic review and meta-analysis of randomised controlled trials.
Populations
Patients scheduled for central venous access.
Intervention reviewed
Guidance using real time two dimensional ultrasonography or Doppler needles and probes compared with the anatomical landmark method of cannulation.
Data extraction
Risk of failed catheter placement (primary outcome), risk of complications from placement, risk of failure on first attempt at placement, number of attempts to successful catheterisation, and time (seconds) to successful catheterisation.
Data synthesis
18 trials (1646 participants) were identified.
Compared with the landmark method, real time two dimensional ultrasound guidance for cannulating the internal jugular vein in adults was associated with a significantly lower failure rate both overall (relative risk 0.
14, 95% confidence interval 0.
06 to 0.
33) and on the first attempt (0.
59, 0.
39 to 0.
88).
Limited evidence favoured two dimensional ultrasound guidance for subclavian vein and femoral vein procedures in adults (0.
14, 0.
04 to 0.
57 and 0.
29, 0.
07 to 1.
21, respectively).
Three studies in infants confirmed a higher success rate with two dimensional ultrasonography for internal jugular procedures (0.
15, 0.
03 to 0.
64).
Doppler guided cannulation of the internal jugular vein in adults was more successful than the landmark method (0.
39, 0.
17 to 0.
92), but the landmark method was more successful for subclavian vein procedures (1.
48, 1.
03 to 2.
14).
No significant difference was found between these techniques for cannulation of the internal jugular vein in infants.
An indirect comparison of relative risks suggested that two dimensional ultrasonography would be more successful than Doppler guidance for subclavian vein procedures in adults (0.
09, 0.
02 to 0.
38).
Conclusions
Evidence supports the use of two dimensional ultrasonography for central venous cannulation.
Related Results
Impacto de los equipos hospitalarios multiprofesionales de acceso vascular guiado por ecografía
Impacto de los equipos hospitalarios multiprofesionales de acceso vascular guiado por ecografía
Introduction
Vascular access is essential for administering intravenous therapies in both hospital and outpatient settings.The traditional technique, based on palpation and visuali...
Ultrasound guidance for difficult peripheral venous access: systematic review and meta-analysis
Ultrasound guidance for difficult peripheral venous access: systematic review and meta-analysis
Background
Establishing intravenous access is often vital in an acute hospital setting but can be difficult. Ultrasound-guided cannulation increases success rates...
Left Versus Right Landmark-Guided Subclavian Cannulation in Cardiogenic Shock: A Retrospective Study in Myanmar
Left Versus Right Landmark-Guided Subclavian Cannulation in Cardiogenic Shock: A Retrospective Study in Myanmar
Background
Rapid central venous access is essential in the management of cardiogenic shock. Although ultrasound-guided internal jugular vein cannulation is widely recommended, lan...
Ultrasound for central venous cannulation: economic evaluation of cost‐effectiveness
Ultrasound for central venous cannulation: economic evaluation of cost‐effectiveness
Summary
We compared the economics of using two‐dimensional ultrasound locating devices and more traditional landmark methods for central venous cannulation in the...
Cannulation Strategies in Acute Type A Aortic Dissection: Is Femoral Cannulation Truly Detrimental?
Cannulation Strategies in Acute Type A Aortic Dissection: Is Femoral Cannulation Truly Detrimental?
Background: The optimal cannulation strategy for acute type A aortic dissection (ATAAD) remains controversial. Femoral artery, axillary artery, ascending aorta, or apical cannulati...
Does early application of needle-knife sphincterotomy (NKS) in patients with difficult biliary cannulation increase the risk of postERCP pancreatitis? A single centre study
Does early application of needle-knife sphincterotomy (NKS) in patients with difficult biliary cannulation increase the risk of postERCP pancreatitis? A single centre study
Objective: To determine that early needle-knife sphincterotomy does not increase post-ERCP pancreatitis in patients with difficult biliary cannulation as compared to standard cannu...
Efficacy of a Novel Medical Device to Aid in Ultrasound-Guided Intravenous Cannulation: Randomized Controlled Non-Clinical Trial
Efficacy of a Novel Medical Device to Aid in Ultrasound-Guided Intravenous Cannulation: Randomized Controlled Non-Clinical Trial
Abstract
Background
Peripheral intravenous (PIV) cannulation is a crucial and frequently performed medical procedure, but achieving successful venous access can be particu...
Predictive Factors Contributing to First-Attempt Failure of Pediatric Nurses Regarding Peripheral Venous Cannulation
Predictive Factors Contributing to First-Attempt Failure of Pediatric Nurses Regarding Peripheral Venous Cannulation
Background: First-attempt peripheral venous cannulation is an important procedure in pediatric practice, but the rates of failure are high, because there are several causes of fail...

