Response time measurement of hygrometers at LNE-CETIAT

View through CrossRef
LNE-CETIAT has been involved in European project JRP HIT – EMPIR (www.empir-hit.eu). The objectives of this project were to improve the accuracy of industrial humidity measurements, to provide new traceability capabilities and to develop new calibration techniques at high temperatures up to 180 °C and under transient conditions. Considering the last aspect, LNE-CETIAT has worked on the development of a humidity step generator for studying response time of hygrometers. Indeed, classical calibrations are performed under quasi-static conditions whilst the end users measurement conditions are, most of the time, non-static or dynamic. In order to tackle this situation, LNE-CETIAT has started to developed dynamic humidity generator which enables response time measurement by applying humidity step to the device under test. In this article the test rig is presented as well as results obtained with chilled mirror hygrometers. A discussion about response time of chilled mirror concludes this work.
Title: Response time measurement of hygrometers at LNE-CETIAT
Description:
LNE-CETIAT has been involved in European project JRP HIT – EMPIR (www.
empir-hit.
eu).
The objectives of this project were to improve the accuracy of industrial humidity measurements, to provide new traceability capabilities and to develop new calibration techniques at high temperatures up to 180 °C and under transient conditions.
Considering the last aspect, LNE-CETIAT has worked on the development of a humidity step generator for studying response time of hygrometers.
Indeed, classical calibrations are performed under quasi-static conditions whilst the end users measurement conditions are, most of the time, non-static or dynamic.
In order to tackle this situation, LNE-CETIAT has started to developed dynamic humidity generator which enables response time measurement by applying humidity step to the device under test.
In this article the test rig is presented as well as results obtained with chilled mirror hygrometers.
A discussion about response time of chilled mirror concludes this work.

Related Results

One-Step Preparation of Luteolin Nanoemulsion and Evaluation of its Anti-inflammatory Effect in Animal Models
One-Step Preparation of Luteolin Nanoemulsion and Evaluation of its Anti-inflammatory Effect in Animal Models
Background: Nanoemulsions are promising drug delivery systems for topical application owing to the high transdermal penetration. Objective: Due to the side effects of existing an...
Objective evaluation of fabric smoothness appearance with an ordinal classification framework based on label noise estimation
Objective evaluation of fabric smoothness appearance with an ordinal classification framework based on label noise estimation
Objective fabric smoothness appearance evaluation plays an important role in the textile and apparel industry. In most previous studies, objective fabric smoothness appearance eval...
Development and metrological characterisation of the new LNE 500 N · m deadweight torque standard machine
Development and metrological characterisation of the new LNE 500 N · m deadweight torque standard machine
This paper describes the development and metrological characterisation of the new LNE 500 N · m deadweight torque standard machine. This machine is integrated into the LNE 5 kN · m...
Calibration of hygrometers with the hybrid humidity generator
Calibration of hygrometers with the hybrid humidity generator
We describe here the calibration of customer hygrometers using the NIST Hybrid Humidity Generator (HHG). This generator produces humidified air with water amount fractions (water m...
EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...
Effect of frequency difference deviation on full-field heterodyne measurement accuracy
Effect of frequency difference deviation on full-field heterodyne measurement accuracy
With the advantages of high precision and great environmental adaptability, laser heterodyne interferometry has been successfullyused in some areas, such as measuring distance and ...
Small Cell Lung Cancer and Tarlatamab: A Meta-Analysis of Clinical Trials
Small Cell Lung Cancer and Tarlatamab: A Meta-Analysis of Clinical Trials
Abstract Introduction Tarlatamab is a Delta-like ligand 3 (DLL3) -directed bispecific T-cell engager recently approved for use in patients with advanced small cell lung cancer (SCL...
Practical Concerns In Metering Fluids From Production Operations
Practical Concerns In Metering Fluids From Production Operations
Abstract Accurate measurement of oil and gas is of vital concern. Measurement of these vapor and liquid streams by mass, volumetric, and energy techniques are rev...

Back to Top