Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Anti‐Motion Artifacts Iontronic Sensor for Long‐Term Accurate Fingertip Pulse Monitoring

View through CrossRef
AbstractFlexible pressure sensors have gained attention for their comfort, portability, and potential in long‐term pulse monitoring and early cardiovascular disease diagnosis. However, stretching stress during daily activities affects sensor accuracy, causing motion artifacts (MAs) that hinder precise pulse signal detection. To address this challenge, the anti‐motion artifact iontronic pressure sensor (S‐smooth sensor), featuring a soft‐hard stretchable interface with energy dissipation properties is developed. By regulating the local modulus of the encapsulation layer, this structure dissipates stretching stress, achieving an MAs suppression rate of up to 90%, significantly improving pulse signal accuracy and reliability. Additionally, the sensor incorporates a dielectric layer and double electrode layer (EDL) sensing interface, with a low‐friction design that ensures high sensitivity (92.76 kPa−¹) and stability, maintaining performance over millions of cycles. The sensor accurately captures heart rate (HR) and pulse peak time differences (Δt) under various finger‐bending conditions. When integrated into a portable wireless pulse monitoring system, it shows a heart rate loss rate of only 2.9% during intense physical activity. This approach avoids complex chemical processes and material restrictions, offering a novel solution for motion artifact suppression in sensors, with significant potential for real‐time health monitoring and assisted diagnosis.
Title: Anti‐Motion Artifacts Iontronic Sensor for Long‐Term Accurate Fingertip Pulse Monitoring
Description:
AbstractFlexible pressure sensors have gained attention for their comfort, portability, and potential in long‐term pulse monitoring and early cardiovascular disease diagnosis.
However, stretching stress during daily activities affects sensor accuracy, causing motion artifacts (MAs) that hinder precise pulse signal detection.
To address this challenge, the anti‐motion artifact iontronic pressure sensor (S‐smooth sensor), featuring a soft‐hard stretchable interface with energy dissipation properties is developed.
By regulating the local modulus of the encapsulation layer, this structure dissipates stretching stress, achieving an MAs suppression rate of up to 90%, significantly improving pulse signal accuracy and reliability.
Additionally, the sensor incorporates a dielectric layer and double electrode layer (EDL) sensing interface, with a low‐friction design that ensures high sensitivity (92.
76 kPa−¹) and stability, maintaining performance over millions of cycles.
The sensor accurately captures heart rate (HR) and pulse peak time differences (Δt) under various finger‐bending conditions.
When integrated into a portable wireless pulse monitoring system, it shows a heart rate loss rate of only 2.
9% during intense physical activity.
This approach avoids complex chemical processes and material restrictions, offering a novel solution for motion artifact suppression in sensors, with significant potential for real‐time health monitoring and assisted diagnosis.

Related Results

Dynamic stochastic modeling for inertial sensors
Dynamic stochastic modeling for inertial sensors
Es ampliamente conocido que los modelos de error para sensores inerciales tienen dos componentes: El primero es un componente determinista que normalmente es calibrado por el fabri...
Fingertip Injuries Conservative Management with Dressing: A Systematic Review
Fingertip Injuries Conservative Management with Dressing: A Systematic Review
Introduction: Fingertip traumatic injuries are known as the most common injuries to the hand. Conservative management is one of the treatment approaches that is purposed to promote...
Real Time Vision Based Fingertip Detection Strategies
Real Time Vision Based Fingertip Detection Strategies
The Fingertip Detection acts a specific role in most of the vision based applications. The latest technologies like virtual reality and augmented reality actually follows this fing...
Real Time Heart Rate Monitoring System
Real Time Heart Rate Monitoring System
Heart rate monitoring systems are critical in modern healthcare, enabling continuous tracking of cardiovascular health. Traditional cloud-based solutions pose privacy risks due to ...
Repair of Fingertip Defect Using an Anterograde Pedicle Flap Based on the Dorsal Perforator
Repair of Fingertip Defect Using an Anterograde Pedicle Flap Based on the Dorsal Perforator
Background. The hand is the most frequently injured body part. Injuries to the fingertips are among the most common hand injuries. In this article an anterograde pedicle flap based...

Back to Top