Javascript must be enabled to continue!
Short-Wavelength Automated Perimetry and Neuroretinal Rim Area
View through CrossRef
Purpose
To determine the correlation between neuroretinal rim area and functional losses detected by short-wavelength automated perimetry (SWAP) in a population of patients with suspected glaucoma.
Methods
Forty-two eyes of 42 ocular hypertensive subjects who met the selection criteria (intraocular pressure greater than 21 mm of Hg and normal conventional visual fields) were studied. A planimetric optic nerve head study was performed, determining the total and sectorized neuroretinal rim areas. SWAP was also done, with a modified Humphrey field analyzer.
Results
There were no significant correlations between the neuroretinal rim areas and the global perimetric parameters. However, the correlations between the inferotemporal neuroretinal rim area and some superonasal visual field regions (areas 3 and 4) were significant.
Conclusions
There is a relation in the topography of some visual field areas assessed by SWAP and the inferotemporal neuroretinal rim area, which may play a role in the diagnosis and follow-up of suspected glaucoma.
Title: Short-Wavelength Automated Perimetry and Neuroretinal Rim Area
Description:
Purpose
To determine the correlation between neuroretinal rim area and functional losses detected by short-wavelength automated perimetry (SWAP) in a population of patients with suspected glaucoma.
Methods
Forty-two eyes of 42 ocular hypertensive subjects who met the selection criteria (intraocular pressure greater than 21 mm of Hg and normal conventional visual fields) were studied.
A planimetric optic nerve head study was performed, determining the total and sectorized neuroretinal rim areas.
SWAP was also done, with a modified Humphrey field analyzer.
Results
There were no significant correlations between the neuroretinal rim areas and the global perimetric parameters.
However, the correlations between the inferotemporal neuroretinal rim area and some superonasal visual field regions (areas 3 and 4) were significant.
Conclusions
There is a relation in the topography of some visual field areas assessed by SWAP and the inferotemporal neuroretinal rim area, which may play a role in the diagnosis and follow-up of suspected glaucoma.
Related Results
SITA standard testing with Humphrey visual field analyzer versus full threshold testing with frequency doubling perimetry: a comparison of patient preference and perception
SITA standard testing with Humphrey visual field analyzer versus full threshold testing with frequency doubling perimetry: a comparison of patient preference and perception
Purpose: To compare patient preference for Swedish Interactive Threshold Algorithm (SITA) standard 24-2 protocol in Humphrey visual field analyzer (HVF) and full threshold N-30 pro...
Discriminating Ability of Humphrey Matrix Perimetry in Early Glaucoma Patients
Discriminating Ability of Humphrey Matrix Perimetry in Early Glaucoma Patients
<i>Purpose:</i> To determine the discriminating ability of some parameters provided by Humphrey Matrix perimetry for early glaucoma detection. <i>Methods:</i&g...
Krupac crater in Sirenum Fossae, Mars: Understanding fresh impact cratering processes
Krupac crater in Sirenum Fossae, Mars: Understanding fresh impact cratering processes
Krupac crater in Sirenum Fossae, Mars: Understanding fresh impact cratering processesS. Vijayan, Harish and Bhalamurugan SivaramanPlanetary Science Division, Physical Research Labo...
HIND LIMB PERIMETRY AND MUSCLE WEIGHT IN HIGH INTENSITY INTERVAL TRAINED RATS
HIND LIMB PERIMETRY AND MUSCLE WEIGHT IN HIGH INTENSITY INTERVAL TRAINED RATS
Interval‐training can be divided into high‐intensity interval training (HIIT – near maximal efforts) and sprint interval training (supramaximal efforts) [1]. Physiological adaptati...
Relationship between HEP perimetry and standard automated perimetry
Relationship between HEP perimetry and standard automated perimetry
Abstract Purpose To evaluate the relationship between Standard Automated Perimetry (SAP) performed with Humphrey perimeter (Carl Zeiss Meditec, EEUU) and a new white‐white perimetr...
Relationship between flicker FDF perimetry and standard automated perimetry
Relationship between flicker FDF perimetry and standard automated perimetry
Abstract Purpose To compare the main indices of flicker FDF perimetry (FDF, Heidelberg Engineering, Germany) with standard automated perimetry (SAP). Methods Twenty healthy subject...
Sensitivity and Specificity of Qualitative Visual Field Tests for Screening Visual Hemifield Deficits in Right-Brain-Damaged Stroke Patients
Sensitivity and Specificity of Qualitative Visual Field Tests for Screening Visual Hemifield Deficits in Right-Brain-Damaged Stroke Patients
A timely detection of visual hemifield deficits (VHFDs; hemianopias or quadrantanopias) is critical for both the diagnosis and treatment of stroke patients. The present study deter...
Propagation of the rim under a liquid-curtain breakup
Propagation of the rim under a liquid-curtain breakup
The propagation speed, shape and stability of the rim generated by a liquid-curtain breakup are studied. In the experiment, a liquid curtain surrounded by a slot die, edge guides a...

