SU‐E‐T‐603: Evaluation of MLC‐Based Robotic Radiotherapy
View through CrossRef
Purpose: A multi‐leaf collimator (MLC) system has been introduced for the CyberKnife M6 system, enabling conformal shaping of beam apertures in robotic radiotherapy. Through a multi‐disease site study, the potential for the use of MLC‐based robotic delivery is assessed for conventionally fractionated regimens. Methods: The InCise MLC, consisting of 41 leaf pairs, with leaf thickness of 2.5 mm at 800 mm SAD, and a maximum field‐of‐view field size of 120 mm × 100 mm was used in conjunction with the MultiPlan 5.0 platform for comparative planning study relative to the pseudo‐conical IRIS variable aperture collimator. Conformal avoidance technique with relaxed convergence was used for the optimization, and identical dose‐volume optimization parameters and normalization (95%) for the comparative studies. Disease sites, including the prostate, partial breast, and peri‐orbit carcinomas were evaluated, and the results were quantified with respect to total monitor units (MUs), treatment time, conformality, and dose‐volume coverage. Results: The MLC system results on average of 3– 4 modulated segments for a series of non‐coplanar nodes. Relative to plans generated by the IRIS variable aperture collimators, the MLC‐based plans resulted in a 38±10% reduction of both the MUs and treatment time. While similar dosimetry is achieved by both systems, for a dose rate of 1000 MU/min, it is shown that treatment times of less than 20 minutes are possible for most conventionally fractionated treatments with the MLC system. Conclusion: A limiting factor in the adaptation of the robotic delivery for conventional radiotherapy has been the prolonged treatment times. The introduction of compact MLC fixture enables reduction of MUs and treatment time, making conventionally fractionated treatments feasible to more efficiently leverage the higher delivering accuracy and intrafraction motion correction capabilities of robotic delivery.
Title: SU‐E‐T‐603: Evaluation of MLC‐Based Robotic Radiotherapy
Description:
Purpose: A multi‐leaf collimator (MLC) system has been introduced for the CyberKnife M6 system, enabling conformal shaping of beam apertures in robotic radiotherapy.
Through a multi‐disease site study, the potential for the use of MLC‐based robotic delivery is assessed for conventionally fractionated regimens.
Methods: The InCise MLC, consisting of 41 leaf pairs, with leaf thickness of 2.
5 mm at 800 mm SAD, and a maximum field‐of‐view field size of 120 mm × 100 mm was used in conjunction with the MultiPlan 5.
0 platform for comparative planning study relative to the pseudo‐conical IRIS variable aperture collimator.
Conformal avoidance technique with relaxed convergence was used for the optimization, and identical dose‐volume optimization parameters and normalization (95%) for the comparative studies.
Disease sites, including the prostate, partial breast, and peri‐orbit carcinomas were evaluated, and the results were quantified with respect to total monitor units (MUs), treatment time, conformality, and dose‐volume coverage.
Results: The MLC system results on average of 3– 4 modulated segments for a series of non‐coplanar nodes.
Relative to plans generated by the IRIS variable aperture collimators, the MLC‐based plans resulted in a 38±10% reduction of both the MUs and treatment time.
While similar dosimetry is achieved by both systems, for a dose rate of 1000 MU/min, it is shown that treatment times of less than 20 minutes are possible for most conventionally fractionated treatments with the MLC system.
Conclusion: A limiting factor in the adaptation of the robotic delivery for conventional radiotherapy has been the prolonged treatment times.
The introduction of compact MLC fixture enables reduction of MUs and treatment time, making conventionally fractionated treatments feasible to more efficiently leverage the higher delivering accuracy and intrafraction motion correction capabilities of robotic delivery.
Related Results
Role of myosin II activity and the regulation of myosin light chain phosphorylation in astrocytomas
Role of myosin II activity and the regulation of myosin light chain phosphorylation in astrocytomas
AbstractThe generation of contractile force mediated by actin‐myosin interactions is essential for cell motility. Myosin activity is promoted by phosphorylation of myosin light cha...
Ca2+- and Myosin Phosphorylation–independent Relaxation by Halothane in K+-depolarized Rat Mesenteric Arteries
Ca2+- and Myosin Phosphorylation–independent Relaxation by Halothane in K+-depolarized Rat Mesenteric Arteries
Background
Volatile anesthetics inhibit vascular smooth muscle contraction, but the mechanisms responsible are uncertain. In this study, the effects of halothane on Ca2...
Inhibition of miR-33a-5p in Macrophage-like Cells In Vitro Promotes apoAI-Mediated Cholesterol Efflux
Inhibition of miR-33a-5p in Macrophage-like Cells In Vitro Promotes apoAI-Mediated Cholesterol Efflux
Atherosclerosis is caused by cholesterol accumulation within arteries. The intima is where atherosclerotic plaque accumulates and where lipid-laden foam cells reside. Intimal foam ...
Evaluating the Cost for Robotic vs “Non-Robotic” Transhiatal Esophagectomy
Evaluating the Cost for Robotic vs “Non-Robotic” Transhiatal Esophagectomy
Introduction
This study was undertaken to analyze and compare the cost of robotic transhiatal esophagectomy (THE) to “non-robotic” THE (ie, “open” and laparosco...
SU‐E‐P‐21: Impact of MLC Position Errors On Simultaneous Integrated Boost Intensity‐Modulated Radiotherapy for Nasopharyngeal Carcinoma
SU‐E‐P‐21: Impact of MLC Position Errors On Simultaneous Integrated Boost Intensity‐Modulated Radiotherapy for Nasopharyngeal Carcinoma
Purpose:To investigate the impact of MLC position errors on simultaneous integrated boost intensity‐modulated radiotherapy (SIB‐IMRT) for patients with nasopharyngeal carcinoma.Met...
Clinical and 18F-FDG PET/CT Imaging Characteristics of Post-radiotherapy Sacral Insufficiency Fractures in Cervical Cancer Patients
Clinical and 18F-FDG PET/CT Imaging Characteristics of Post-radiotherapy Sacral Insufficiency Fractures in Cervical Cancer Patients
Introduction:
Sacral Insufficiency Fractures (SIFs) are a common yet frequently misdiagnosed late complication following pelvic radiotherapy for cervical
cancer...
Developing the advanced dosimetry of linac beam radiotherapy
Developing the advanced dosimetry of linac beam radiotherapy
<p dir="ltr">Photon beams remains the most widely used modality for radiotherapy of cancer worldwide. Continued technological development has enabled increasingly conformal t...
Developing the advanced dosimetry of linac beam radiotherapy
Developing the advanced dosimetry of linac beam radiotherapy
<p dir="ltr">Photon beams remains the most widely used modality for radiotherapy of cancer worldwide. Continued technological development has enabled increasingly conformal t...