Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Optimum Meridian Profile With Additional Criteria

View through CrossRef
In the previous paper, the optimum meridian profile of impeller and guidevane was obtained improving efficiency and cavitation performance. But, the meridian profile of impeller and guidevane is necessary to be decided by the consideration of various operative conditions for the practical use. In particularly, it is important that the separation flow in impeller and guidevane is suppressed in partial flow rate. In this paper, the optimum meridian profile of impeller and guidevane is calculated by considering the partial flow rate operative condition. That is, the optimum criteria are the efficiency, the cavitation performance and the partial flow rate operative condition. The partial flow rate operative condition is expressed by the limited condition of diffusion factor (e.g. Deq = 2). In the optimum procedure, the meridian profile is improved considering diffusion factor at partial flow rate in tip, mid-span and hub stream lines of impeller and guidevane become to the objective value (e.g. Deq = 2) in specified partial flow rate (e.g. Qpartial = 0.5Q). The equation of partial flow rate diffusion factor is expressed by partial inlet-outlet flow condition and additional term expressed by increase of attack angle at impeller inlet and at guidevane inlet. As the result, the optimum meridian profile considering partial flow rate operative condition is obtained.
Title: Optimum Meridian Profile With Additional Criteria
Description:
In the previous paper, the optimum meridian profile of impeller and guidevane was obtained improving efficiency and cavitation performance.
But, the meridian profile of impeller and guidevane is necessary to be decided by the consideration of various operative conditions for the practical use.
In particularly, it is important that the separation flow in impeller and guidevane is suppressed in partial flow rate.
In this paper, the optimum meridian profile of impeller and guidevane is calculated by considering the partial flow rate operative condition.
That is, the optimum criteria are the efficiency, the cavitation performance and the partial flow rate operative condition.
The partial flow rate operative condition is expressed by the limited condition of diffusion factor (e.
g.
Deq = 2).
In the optimum procedure, the meridian profile is improved considering diffusion factor at partial flow rate in tip, mid-span and hub stream lines of impeller and guidevane become to the objective value (e.
g.
Deq = 2) in specified partial flow rate (e.
g.
Qpartial = 0.
5Q).
The equation of partial flow rate diffusion factor is expressed by partial inlet-outlet flow condition and additional term expressed by increase of attack angle at impeller inlet and at guidevane inlet.
As the result, the optimum meridian profile considering partial flow rate operative condition is obtained.

Related Results

Telocytes in Different Organs of Vertebrates: Potential Essence Cells of the Meridian in Chinese Traditional Medicine
Telocytes in Different Organs of Vertebrates: Potential Essence Cells of the Meridian in Chinese Traditional Medicine
AbstractTelocytes (TCs) are very long, non-neuronal, somatic cells whose function is widely believed to be involved in providing connections between different cells within the body...
Case Study of Multi-Stage Impeller with Guidevane
Case Study of Multi-Stage Impeller with Guidevane
In the previous paper, the optimum meridian profile of impeller was obtained for various specific speed by means of eight shape factors, that is, inlet relative flow angle β1, turn...
A Study on Cheng Guopeng (程國彭)’s Understanding of Shanghan Disease (傷寒病) Through Yixuexinwu (醫學心悟)
A Study on Cheng Guopeng (程國彭)’s Understanding of Shanghan Disease (傷寒病) Through Yixuexinwu (醫學心悟)
Objective and Methods: This study examined Cheng Guopeng (程國彭)’s understanding of Shanghan Disease (傷寒病) through <Yixue xinwu (醫學心悟)>, created tables based on this, and these...
A Meridian Profile Obtained by No Restriction in Optimum Process
A Meridian Profile Obtained by No Restriction in Optimum Process
In previous study of optimum meridian profile of impeller and guide-vane, almost all design parameters included in the specific speed and blade number are variable design parameter...
The primo vascular system is the substance of meridians.
The primo vascular system is the substance of meridians.
Abstract Background; The primo vascular system (PVS) is new circulatory system. However, the primo vascular system doesn’t achieve now on the valuation criteria on the subs...
Non-Recommended Publishing Lists: Strategies for Detecting Deceitful Journals
Non-Recommended Publishing Lists: Strategies for Detecting Deceitful Journals
Abstract The rapid growth of open access publishing (OAP) has significantly improved the accessibility and dissemination of scientific knowledge. However, this expansion has also c...
Comparative Analysis of Disposable Cranial Perforators in Trepanation
Comparative Analysis of Disposable Cranial Perforators in Trepanation
BACKGROUND AND OBJECTIVES: Cranial trepanation is a fundamental neurosurgical procedure that has evolved significantly with the development of disposable cranial perfor...

Back to Top