Javascript must be enabled to continue!
Optimum Meridian Profile With Additional Criteria
View through CrossRef
In the previous paper, the optimum meridian profile of impeller and guidevane was obtained improving efficiency and cavitation performance. But, the meridian profile of impeller and guidevane is necessary to be decided by the consideration of various operative conditions for the practical use. In particularly, it is important that the separation flow in impeller and guidevane is suppressed in partial flow rate. In this paper, the optimum meridian profile of impeller and guidevane is calculated by considering the partial flow rate operative condition. That is, the optimum criteria are the efficiency, the cavitation performance and the partial flow rate operative condition. The partial flow rate operative condition is expressed by the limited condition of diffusion factor (e.g. Deq = 2). In the optimum procedure, the meridian profile is improved considering diffusion factor at partial flow rate in tip, mid-span and hub stream lines of impeller and guidevane become to the objective value (e.g. Deq = 2) in specified partial flow rate (e.g. Qpartial = 0.5Q). The equation of partial flow rate diffusion factor is expressed by partial inlet-outlet flow condition and additional term expressed by increase of attack angle at impeller inlet and at guidevane inlet. As the result, the optimum meridian profile considering partial flow rate operative condition is obtained.
Title: Optimum Meridian Profile With Additional Criteria
Description:
In the previous paper, the optimum meridian profile of impeller and guidevane was obtained improving efficiency and cavitation performance.
But, the meridian profile of impeller and guidevane is necessary to be decided by the consideration of various operative conditions for the practical use.
In particularly, it is important that the separation flow in impeller and guidevane is suppressed in partial flow rate.
In this paper, the optimum meridian profile of impeller and guidevane is calculated by considering the partial flow rate operative condition.
That is, the optimum criteria are the efficiency, the cavitation performance and the partial flow rate operative condition.
The partial flow rate operative condition is expressed by the limited condition of diffusion factor (e.
g.
Deq = 2).
In the optimum procedure, the meridian profile is improved considering diffusion factor at partial flow rate in tip, mid-span and hub stream lines of impeller and guidevane become to the objective value (e.
g.
Deq = 2) in specified partial flow rate (e.
g.
Qpartial = 0.
5Q).
The equation of partial flow rate diffusion factor is expressed by partial inlet-outlet flow condition and additional term expressed by increase of attack angle at impeller inlet and at guidevane inlet.
As the result, the optimum meridian profile considering partial flow rate operative condition is obtained.
Related Results
Case Study of Multi-Stage Impeller with Guidevane
Case Study of Multi-Stage Impeller with Guidevane
In the previous paper, the optimum meridian profile of impeller was obtained for various specific speed by means of eight shape factors, that is, inlet relative flow angle β1, turn...
A Study on Cheng Guopeng (程國彭)’s Understanding of Shanghan Disease (傷寒病) Through Yixuexinwu (醫學心悟)
A Study on Cheng Guopeng (程國彭)’s Understanding of Shanghan Disease (傷寒病) Through Yixuexinwu (醫學心悟)
Objective and Methods: This study examined Cheng Guopeng (程國彭)’s understanding of Shanghan Disease (傷寒病) through <Yixue xinwu (醫學心悟)>, created tables based on this, and these...
A Meridian Profile Obtained by No Restriction in Optimum Process
A Meridian Profile Obtained by No Restriction in Optimum Process
In previous study of optimum meridian profile of impeller and guide-vane, almost all design parameters included in the specific speed and blade number are variable design parameter...
The primo vascular system is the substance of meridians.
The primo vascular system is the substance of meridians.
Abstract
Background; The primo vascular system (PVS) is new circulatory system. However, the primo vascular system doesn’t achieve now on the valuation criteria on the subs...
Presaccadic attention enhances contrast sensitivity, but not at the upper vertical meridian
Presaccadic attention enhances contrast sensitivity, but not at the upper vertical meridian
AbstractHuman visual performance is not only better at the fovea and decreases with eccentricity, but also has striking radial asymmetries around the visual field: At a fixed eccen...
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Abstract
The Physical Activity Guidelines for Americans (Guidelines) advises older adults to be as active as possible. Yet, despite the well documented benefits of physical a...
Profile–profile methods provide improved fold‐recognition: A study of different profile–profile alignment methods
Profile–profile methods provide improved fold‐recognition: A study of different profile–profile alignment methods
AbstractTo improve the detection of related proteins, it is often useful to include evolutionary information for both the query and target proteins. One method to include this info...
The Diagnostic Accuracy of the Refined EBMT Criteria 2023 for SOS
The Diagnostic Accuracy of the Refined EBMT Criteria 2023 for SOS
Introduction:
Sinusoidal obstruction syndrome (SOS) is a rare but serious complication of allogeneic hematopoietic stem cell transplantation (allo-HSCT). An early...

