Dosimetric comparison of photon beam profile characteristics for different treatment parameters

View through CrossRef
AbstractPurposeTo deliver radiation doses with higher accuracy, radiation treatment through megavoltage photon beams from linear accelerators, is accepted widely for treating malignancies. Before calibrating the linear accelerators, it is essential to make a complete analysis of all photon beam profile parameters. The main objective of this exploration was to investigate the 6 and 15 MV photon beam profile characteristics to improve the accuracy of radiation treatment plans.MethodsIn this exploration, treatment parameters like depth, field size and beam energy were varied to observe their effect on dosimetric characteristics of beam profiles in a water phantom, generated by linear accelerator Varian Clinac.ResultsThe results revealed thatDmaxandDmindecreased with increasing depth but increased with increasing field sizes. Both left and right penumbras increased with increasing depth, field size and energy. Homogeneity increased with field size but decreased with depth. Symmetry had no dependence on depth, energy and field size.ConclusionAll the characteristics of photon beam dosimetry were analysed and the characteristics like homogeneity and symmetry measured by an ion chamber in a water phantom came within clinically acceptable level of 3 and 103%, respectively, thus fulfilled the requirements of standard linear accelerator specifications. This exploration can be extended to the determination of beam profile characteristics of electron and photon beams of other energies at various depths and field sizes for designing optimum treatment plans.
Title: Dosimetric comparison of photon beam profile characteristics for different treatment parameters
Description:
AbstractPurposeTo deliver radiation doses with higher accuracy, radiation treatment through megavoltage photon beams from linear accelerators, is accepted widely for treating malignancies.
Before calibrating the linear accelerators, it is essential to make a complete analysis of all photon beam profile parameters.
The main objective of this exploration was to investigate the 6 and 15 MV photon beam profile characteristics to improve the accuracy of radiation treatment plans.
MethodsIn this exploration, treatment parameters like depth, field size and beam energy were varied to observe their effect on dosimetric characteristics of beam profiles in a water phantom, generated by linear accelerator Varian Clinac.
ResultsThe results revealed thatDmaxandDmindecreased with increasing depth but increased with increasing field sizes.
Both left and right penumbras increased with increasing depth, field size and energy.
Homogeneity increased with field size but decreased with depth.
Symmetry had no dependence on depth, energy and field size.
ConclusionAll the characteristics of photon beam dosimetry were analysed and the characteristics like homogeneity and symmetry measured by an ion chamber in a water phantom came within clinically acceptable level of 3 and 103%, respectively, thus fulfilled the requirements of standard linear accelerator specifications.
This exploration can be extended to the determination of beam profile characteristics of electron and photon beams of other energies at various depths and field sizes for designing optimum treatment plans.

Related Results

On Optimization of Mixed Photon Energies in Volumetric Modulated Arc Therapy
On Optimization of Mixed Photon Energies in Volumetric Modulated Arc Therapy
<p>This dissertation investigates the dosimetric influence of mixed photon beams in volumetric modulated arc therapy (VMAT) for prostate cancer and presents new algorithmic f...
On Optimization of Mixed Photon Energies in Volumetric Modulated Arc Therapy
On Optimization of Mixed Photon Energies in Volumetric Modulated Arc Therapy
<p>This dissertation investigates the dosimetric influence of mixed photon beams in volumetric modulated arc therapy (VMAT) for prostate cancer and presents new algorithmic f...
The photon blockade effect of a complete Buck-Sukumar model
The photon blockade effect of a complete Buck-Sukumar model
The Buck-Sukumar (BS) model, with a nonlinear coupling between the atom and the light field, is well defined only when its coupling strength is lower than a critical coupling. Its ...
Shadow and photon ring of black hole in asymptotically safe gravity
Shadow and photon ring of black hole in asymptotically safe gravity
In this paper, we focus on discussing the influence of thin disk accretion and asymptotically safe (AS) gravity correction parameter on the shadow and photon ring of black holes. F...
Benchmarking a GATE/Geant4 Monte Carlo model for proton beams in magnetic fields
Benchmarking a GATE/Geant4 Monte Carlo model for proton beams in magnetic fields
PurposeMagnetic resonance guidance in proton therapy (MRPT) is expected to improve its current performance. The combination of magnetic fields with clinical proton beam lines poses...
Impact of Common Anticoagulants on Complete Blood Count Parameters Among Humans
Impact of Common Anticoagulants on Complete Blood Count Parameters Among Humans
Abstract Introduction Among the most frequently used anticoagulants in hematological testing are tetra-acetic acid (EDTA), sodium citrate, and sodium heparin. However, there is a n...

Back to Top