Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

P3578Determinants of visual-functional mismatches as assessed by coronary angiography and 3-D angiography-based quantitative flow ratio

View through CrossRef
Abstract Background Quantitative flow ratio (QFR) is a novel three-dimensional quantitative coronary angiography (QCA)-based computational index that can estimate fractional flow reserve (FFR) without pharmacologically induced hyperemia or the use of a pressure wire. Purpose We aimed to evaluate the determinants of visual-functional mismatches between conventional two-dimensional QCA and QFR. Methods A total of 504 de novo intermediate-to-severe lesions from 504 patients with stable angina who underwent angiographical and physiological assessments were analyzed. All lesions were divided into four groups based on the significance of visual (QCA-diameter stenosis [DS] >50% and ≤50%) and functional (QFR <0.80 and ≥0.80) stenosis severity. Patient characteristics, angiographic findings, QFR computations, and physiological indices were compared among the four groups. Results Among 504 lesions, 153 lesions (30.4%) showed concordantly negative (DS ≤50% and QFR >0.80) and 170 lesions (33.7%) showed concordantly positive (DS >50% and QFR ≤0.80) visual and functional assessments. Among 181 lesions (35.9%) with discordant results, 75 lesions (14.9%) showed a mismatch (DS >50% and QFR >0.80) and 106 lesions (21.0%) showed a reverse mismatch (DS ≤50% and QFR ≤0.80), respectively. Reverse mismatch was associated with smaller reference diameter (odds ratio [OR] 0.561; P=0.036), greater DS (OR 1.039, P=0.013), lower coronary flow reserve (CFR) (OR 0.571, P<0.001, non-diabetes mellitus (OR 2.141, P=0.013) and lower ejection fraction (OR 0.961, P=0.011). Mismatch was associated with smaller DS (OR 0.914, P<0.001), shorter lesion length (OR 0.894, P=0.001), higher CFR (OR 1,633, P<0.001), and lower estimated glomerular filtration rate (OR, 0.968, P=0.001). Lesion location and the index of microcirculatory resistance was not associated with the prevalence of reverse mismatch or mismatch. Conclusions There was a high prevalence of visual-functional mismatches between QCA-DS and QFR, and CFR was an important functional factor of mismatches. Our results suggested the difference between predictors of reported visual-functional mismatches of QCA/FFR and those of QCA/QFR.
Title: P3578Determinants of visual-functional mismatches as assessed by coronary angiography and 3-D angiography-based quantitative flow ratio
Description:
Abstract Background Quantitative flow ratio (QFR) is a novel three-dimensional quantitative coronary angiography (QCA)-based computational index that can estimate fractional flow reserve (FFR) without pharmacologically induced hyperemia or the use of a pressure wire.
Purpose We aimed to evaluate the determinants of visual-functional mismatches between conventional two-dimensional QCA and QFR.
Methods A total of 504 de novo intermediate-to-severe lesions from 504 patients with stable angina who underwent angiographical and physiological assessments were analyzed.
All lesions were divided into four groups based on the significance of visual (QCA-diameter stenosis [DS] >50% and ≤50%) and functional (QFR <0.
80 and ≥0.
80) stenosis severity.
Patient characteristics, angiographic findings, QFR computations, and physiological indices were compared among the four groups.
Results Among 504 lesions, 153 lesions (30.
4%) showed concordantly negative (DS ≤50% and QFR >0.
80) and 170 lesions (33.
7%) showed concordantly positive (DS >50% and QFR ≤0.
80) visual and functional assessments.
Among 181 lesions (35.
9%) with discordant results, 75 lesions (14.
9%) showed a mismatch (DS >50% and QFR >0.
80) and 106 lesions (21.
0%) showed a reverse mismatch (DS ≤50% and QFR ≤0.
80), respectively.
Reverse mismatch was associated with smaller reference diameter (odds ratio [OR] 0.
561; P=0.
036), greater DS (OR 1.
039, P=0.
013), lower coronary flow reserve (CFR) (OR 0.
571, P<0.
001, non-diabetes mellitus (OR 2.
141, P=0.
013) and lower ejection fraction (OR 0.
961, P=0.
011).
Mismatch was associated with smaller DS (OR 0.
914, P<0.
001), shorter lesion length (OR 0.
894, P=0.
001), higher CFR (OR 1,633, P<0.
001), and lower estimated glomerular filtration rate (OR, 0.
968, P=0.
001).
Lesion location and the index of microcirculatory resistance was not associated with the prevalence of reverse mismatch or mismatch.
Conclusions There was a high prevalence of visual-functional mismatches between QCA-DS and QFR, and CFR was an important functional factor of mismatches.
Our results suggested the difference between predictors of reported visual-functional mismatches of QCA/FFR and those of QCA/QFR.

Related Results

Early Onset of Coronary Subclavian Steal Syndrome: A Case Report and Literature Review
Early Onset of Coronary Subclavian Steal Syndrome: A Case Report and Literature Review
Abstract Introduction Coronary subclavian steal syndrome (CSSS) is a rare phenomenon that often goes undiagnosed and causes severe complications, including death. This report prese...
Magnetic resonance measurement of coronary blood flow
Magnetic resonance measurement of coronary blood flow
Magnetic resonance (MR) flow measurement in the coronary artery can be achieved with either a breath‐hold acquisition or a respiration‐triggered acquisition. MR measurements of car...
Ritelatur Review: Prosedur Pemeriksaan Coronary Angiogrhpy (Cag) Pada Kasus Acute Trasmular Myocardial Infraction
Ritelatur Review: Prosedur Pemeriksaan Coronary Angiogrhpy (Cag) Pada Kasus Acute Trasmular Myocardial Infraction
Literature review: coronary angiography examination procedure in cases of acute trasmular myocardial infarction. Background: Acute transmural myocardial infarction (ATMI) is a crit...
Coronary physiology
Coronary physiology
The major areas of normal coronary physiological research since Berne's 1964 review have been the measurement of ventricular transmural blood flow distribution with microspheres, t...
Feasibility of energy-resolved angiography
Feasibility of energy-resolved angiography
<p dir="ltr">Cardiovascular disease (CVD) is the leading cause of death globally, with coronary heart disease being one of the most common types of CVD. Two-dimensional x-ray...
Feasibility of energy-resolved angiography
Feasibility of energy-resolved angiography
<p dir="ltr">Cardiovascular disease (CVD) is the leading cause of death globally, with coronary heart disease being one of the most common types of CVD. Two-dimensional x-ray...

Back to Top