Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Single-shot simplified cardioneuroablation

View through CrossRef
Abstract Introduction Cardioneuroablation (CNA) is a promising therapy of a spectrum of arrhythmias dependent on increased activity of parasympathetic tone. The right anterior ganglionated plexus (RAGP), localized paraseptally between right atrium and right superior pulmonary vein, is frequently a primary target for CNA. Methods are sought to determine exact locations of RAGP to minimize ablation lesion set during CNA. Immediate and accurate intraprocedural visualization of RAGP area in patients undergoing CNA is desirable. Methods Consecutive patients who underwent right-atrial CNA for reflex syncope, symptomatic bradycardia or vagal atrial fibrillation were included into the study. After venous contrast injection a 3-dimensional rotational atrial scan (3DRAS) was used to obtain digital images. Next, manual segmentation (MS) of hypodense areas between the right atrium (RA) and the right superior pulmonary vein (RSPV) was performed to reconstruct RAGP. Using 3-dimensional mapping system such created 3D RAGP area visualisation was automatically synchronized with fluoroscopy and these sites were targeted for CNA. Heart rate (HR) acceleration ≥30% and ultra-short-term deceleration capacity (UST-DC) were used for determination of acute CNA outcomes. Results Five patients (3 males, age 37±17) underwent 3DRAS and MS of RAGP area during CNA. A single radiofrequency lesion was delivered in each patient (mean RF time - 33±15s, power - 25W). The mean procedure time was 40±13 minutes. Targeted HR acceleration was achieved in all patients (baseline HR vs post-CNA HR, 57±8bpm vs 93±11bpm; p=0.0007; mean HR acceleration 65±15%). UST-DC significantly decreased after CNA (pre-CNA UST-DC vs post-CNA UST-DC, 13.6ms vs 3.2ms, p=0.00096). There were no complications. Conclusions Single-shot simplified CNA is feasible. Visualization of RAGP area using 3DRAS and MS is safe, effective and can very rapidly delineate CNA target.Figure
Title: Single-shot simplified cardioneuroablation
Description:
Abstract Introduction Cardioneuroablation (CNA) is a promising therapy of a spectrum of arrhythmias dependent on increased activity of parasympathetic tone.
The right anterior ganglionated plexus (RAGP), localized paraseptally between right atrium and right superior pulmonary vein, is frequently a primary target for CNA.
Methods are sought to determine exact locations of RAGP to minimize ablation lesion set during CNA.
Immediate and accurate intraprocedural visualization of RAGP area in patients undergoing CNA is desirable.
Methods Consecutive patients who underwent right-atrial CNA for reflex syncope, symptomatic bradycardia or vagal atrial fibrillation were included into the study.
After venous contrast injection a 3-dimensional rotational atrial scan (3DRAS) was used to obtain digital images.
Next, manual segmentation (MS) of hypodense areas between the right atrium (RA) and the right superior pulmonary vein (RSPV) was performed to reconstruct RAGP.
Using 3-dimensional mapping system such created 3D RAGP area visualisation was automatically synchronized with fluoroscopy and these sites were targeted for CNA.
Heart rate (HR) acceleration ≥30% and ultra-short-term deceleration capacity (UST-DC) were used for determination of acute CNA outcomes.
Results Five patients (3 males, age 37±17) underwent 3DRAS and MS of RAGP area during CNA.
A single radiofrequency lesion was delivered in each patient (mean RF time - 33±15s, power - 25W).
The mean procedure time was 40±13 minutes.
Targeted HR acceleration was achieved in all patients (baseline HR vs post-CNA HR, 57±8bpm vs 93±11bpm; p=0.
0007; mean HR acceleration 65±15%).
UST-DC significantly decreased after CNA (pre-CNA UST-DC vs post-CNA UST-DC, 13.
6ms vs 3.
2ms, p=0.
00096).
There were no complications.
Conclusions Single-shot simplified CNA is feasible.
Visualization of RAGP area using 3DRAS and MS is safe, effective and can very rapidly delineate CNA target.
Figure.

Related Results

Cardioneuroablation: Catheter Vagal Denervation as a New Therapy for Cardioinhibitory Syncope
Cardioneuroablation: Catheter Vagal Denervation as a New Therapy for Cardioinhibitory Syncope
The vasovagal syncope is the most frequent cause of transient loss of consciousness, especially in young people without significant heart disease. The malignant cardioinhibitory fo...
EMNet: A Novel Few-Shot Image Classification Model with Enhanced Self-Correlation Attention and Multi-Branch Joint Module
EMNet: A Novel Few-Shot Image Classification Model with Enhanced Self-Correlation Attention and Multi-Branch Joint Module
In this research, inspired by the principles of biological visual attention mechanisms and swarm intelligence found in nature, we present an Enhanced Self-Correlation Attention and...
Study on hardness and wear resistance of shot peened AA7075-T6 aluminum alloy
Study on hardness and wear resistance of shot peened AA7075-T6 aluminum alloy
Abstract AA7075-T6 aluminum alloy samples were shot peened at various shot peening pressures in the range of 10–70 psi to study their mechanical and tribological ...
Pulmonary vein stenosis post cryo AF ablation using single shot 4-minute freeze technique
Pulmonary vein stenosis post cryo AF ablation using single shot 4-minute freeze technique
Abstract Funding Acknowledgements Type of funding sources: Foundation. Main funding source(s): Magdi Yacoub foundation ...
Comparative Evaluation of Zero-Shot and Few-Shot Performance of Large Language Models in Low-Resource Language Machine Translation
Comparative Evaluation of Zero-Shot and Few-Shot Performance of Large Language Models in Low-Resource Language Machine Translation
Large language models (LLMs) have demonstrated remarkable translation capabilities for high-resource languages, yet their effectiveness on low-resource languages under varying prom...
Automatic Acquisition Method and Empirical Research of Shot Length in Chinese Films based on Machine Vision
Automatic Acquisition Method and Empirical Research of Shot Length in Chinese Films based on Machine Vision
Abstract The measurement of shot length is an essential index for the evaluation of cinematographic research. Given the limitations of existing measurement tools, which req...
Water Jet Shot Peening Strengthening Surface Roughness
Water Jet Shot Peening Strengthening Surface Roughness
Shot peening pressure, nozzle scanning velocity, and target distance were chosen as effect factors when shot peening test to 45 steel and 2Al1 aluminum alloy material was made by w...
Identify Cricket Shots using Machine Learning
Identify Cricket Shots using Machine Learning
Cricket shot detection is a game-changing technology that offers deep insights into player performance and match data, completely changing the way the sport is played. The main ele...

Back to Top