Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

A Low-Cost Markerless motion capture system to automate Functional Gait Assessment: Feasibility Study

View through CrossRef
Abstract Functional gait assessments in older adults have traditionally required manual in-person quantification of clinical measures such as walking speed and step placement. This reliance on individuals trained in motion analysis hinders the frequency with which they are performed, and reduces their generalizability and replicability. To standardize, simplify, and broaden access to gait assessments we here deploy recently-developed open-source tools to produce a low-cost, AI driven markerless motion capture system with custom analysis software for Functional Gait Assessment. Our system uses 3 Cameras, and was validated with a traditional marker-based system on subjects (N=3), showing strong correlation to laboratory-standard measures of step length ( R 2 =0.98), step width ( R 2 =0.97), and head speed ( R 2 =0.95). The markerless system’s FGA reports demonstrated data similar to previous FGA findings in older adult subjects (N=5). Moreover, supplemental standard biomechanical gait measures Step Width, walking Duration, and continuous Gait Speed may be integrated to augment existing FGA. This study demonstrates a proof-of-principle open-source markerless system for analyses of functional gait.
Title: A Low-Cost Markerless motion capture system to automate Functional Gait Assessment: Feasibility Study
Description:
Abstract Functional gait assessments in older adults have traditionally required manual in-person quantification of clinical measures such as walking speed and step placement.
This reliance on individuals trained in motion analysis hinders the frequency with which they are performed, and reduces their generalizability and replicability.
To standardize, simplify, and broaden access to gait assessments we here deploy recently-developed open-source tools to produce a low-cost, AI driven markerless motion capture system with custom analysis software for Functional Gait Assessment.
Our system uses 3 Cameras, and was validated with a traditional marker-based system on subjects (N=3), showing strong correlation to laboratory-standard measures of step length ( R 2 =0.
98), step width ( R 2 =0.
97), and head speed ( R 2 =0.
95).
The markerless system’s FGA reports demonstrated data similar to previous FGA findings in older adult subjects (N=5).
Moreover, supplemental standard biomechanical gait measures Step Width, walking Duration, and continuous Gait Speed may be integrated to augment existing FGA.
This study demonstrates a proof-of-principle open-source markerless system for analyses of functional gait.

Related Results

Making Sense of Sensor Data
Making Sense of Sensor Data
Every year, approximately 12.2 million people worldwide experience a stroke, placing a significant burden on individuals, families, and healthcare systems. Despite rehabilitation, ...
Gait Training Techniques in Children
Gait Training Techniques in Children
The development of gait is a fundamental milestone in childhood that signifies the onset of functional independence, social engagement, and cognitive exploration. The book “Gait Tr...
Gait assessments in patients with early Parkinson's disease
Gait assessments in patients with early Parkinson's disease
Introduction : Gait disturbances are affected in all stages of PD. At the early stages of the disease, gait disturbances can be present but in most patients, it does not cause sign...
Validity of self-reporting of gait alteration after tap test among patients with idiopathic normal pressure hydrocephalus
Validity of self-reporting of gait alteration after tap test among patients with idiopathic normal pressure hydrocephalus
PurposeThe study aimed to examine the validity of self-reporting as an additional method to indicate gait alteration among patients with idiopathic normal pressure hydrocephalus. T...
Distinct roles of the human cuneiform and pedunculopontine nuclei in gait and freezing of gait
Distinct roles of the human cuneiform and pedunculopontine nuclei in gait and freezing of gait
Abstract Freezing of gait (FOG) in Parkinson’s disease (PD) is a major cause of disability, often resistant to dopaminergic therapy and deep brain stimulation (DB...
MMF-Gait: A Multi-Model Fusion-Enhanced Gait Recognition Framework Integrating Convolutional and Attention Networks
MMF-Gait: A Multi-Model Fusion-Enhanced Gait Recognition Framework Integrating Convolutional and Attention Networks
Gait recognition is a reliable biometric approach that uniquely identifies individuals based on their natural walking patterns. It is widely used to recognize individuals who are c...
Crutch gait patterns characterization through spatial and temporal parameters
Crutch gait patterns characterization through spatial and temporal parameters
(English) Crutches are widely used as assistive walking devices for a diverse population. They are often prescribed by clinicians/therapists to help offload the lower extremities ...
Quantitative parameters of the kinetics and kinematics of the iatrogenic crouch gait pattern
Quantitative parameters of the kinetics and kinematics of the iatrogenic crouch gait pattern
The pattern of pathological crouch gait in patients with spastic paralysis is characteristic of diplegic forms and in natural development manifests itself usually after the age of ...

Back to Top