Corrosion Properties of Inconel Alloy 600 Coated by Simultaneous Aluminizing-Chromizing Process
View through CrossRef
In this work Inconel 600 alloy was coated with two different types of coatings, Crmodified
aluminide coating and Y- doped chromium modified aluminide coating . Diffusion coating
was carried at 1050 oC for 8 hrs under Ar atmosphere by single step aluminizing- chromizing process
and by single step aluminizing- chromizing- yttriumizing process. The cyclic hot corrosion tests of IN
600 and its coated systems deposited with 2 mg / cm2 NaCl / Na2SO4 (100/0, 50/50, and 0/100 wt. %)
deposits were conducted at 900 oC in air for 105 hrs at 15 hrs cycle.
The hot corrosion kinetic of uncoated Inconel 600 alloy follows parabolic rate law when oxidized
with 100% Na2SO4 deposits, whereas it follows a linear rate law when oxidized with 100% NaCl
deposits and with (50% NaCl + 50% Na2SO4) deposits. In cyclic hot corrosion tests, the parabolic rate
constant (kP) values for Cr- modified aluminide coating when oxidized with NaCl / Na2SO4
concentrations (100/0, 50/50, and 0/100 wt. %) deposits are: 2.67x10-6, 2.73x10-6, and 8.34x10-7
(mg2/cm4)/s. respectively. But for Y- doped chromium modified aluminide coating are: 2.10x10-6,
1.51x10-6, and 6.66x10-7 (mg2/cm4)/s. respectively, under the same test conditions. The kP values for
both coated systems oxidized with 100% Na2SO4 deposits are one order of magnitude lower than that
for 100% NaCl, and for (50% NaCl + 50% Na2SO4) deposits under the same test conditions.
Title: Corrosion Properties of Inconel Alloy 600 Coated by Simultaneous Aluminizing-Chromizing Process
Description:
In this work Inconel 600 alloy was coated with two different types of coatings, Crmodified
aluminide coating and Y- doped chromium modified aluminide coating .
Diffusion coating
was carried at 1050 oC for 8 hrs under Ar atmosphere by single step aluminizing- chromizing process
and by single step aluminizing- chromizing- yttriumizing process.
The cyclic hot corrosion tests of IN
600 and its coated systems deposited with 2 mg / cm2 NaCl / Na2SO4 (100/0, 50/50, and 0/100 wt.
%)
deposits were conducted at 900 oC in air for 105 hrs at 15 hrs cycle.
The hot corrosion kinetic of uncoated Inconel 600 alloy follows parabolic rate law when oxidized
with 100% Na2SO4 deposits, whereas it follows a linear rate law when oxidized with 100% NaCl
deposits and with (50% NaCl + 50% Na2SO4) deposits.
In cyclic hot corrosion tests, the parabolic rate
constant (kP) values for Cr- modified aluminide coating when oxidized with NaCl / Na2SO4
concentrations (100/0, 50/50, and 0/100 wt.
%) deposits are: 2.
67x10-6, 2.
73x10-6, and 8.
34x10-7
(mg2/cm4)/s.
respectively.
But for Y- doped chromium modified aluminide coating are: 2.
10x10-6,
1.
51x10-6, and 6.
66x10-7 (mg2/cm4)/s.
respectively, under the same test conditions.
The kP values for
both coated systems oxidized with 100% Na2SO4 deposits are one order of magnitude lower than that
for 100% NaCl, and for (50% NaCl + 50% Na2SO4) deposits under the same test conditions.
Related Results
[RETRACTED] Diaetoxyl 600 mg : Detoxil 600 mg : Detoxil 600 MG En Pharmacie : Diaetoxyl Avis v1
[RETRACTED] Diaetoxyl 600 mg : Detoxil 600 mg : Detoxil 600 MG En Pharmacie : Diaetoxyl Avis v1
[RETRACTED] NOS SITES OFFICIELS POUR ACHETERSERVEUR 1https://ipsnews.net/business/2022/07/01/diaetoxil-avis-france-gelules-diaetoxil-erfahrungen-bezugsquellen-entgiftung-avis/SERVE...
[RETRACTED] Diaetoxyl 600 mg : Ce produit est-il légitime ou une arnaque ? v1
[RETRACTED] Diaetoxyl 600 mg : Ce produit est-il légitime ou une arnaque ? v1
[RETRACTED]Qu'est-ce que le Diaetoxyl 600 mg? Derrière le nom Diaetoxyl 600 mg se cache une préparation dite "amaigrissante". Selon le fabricant, l'objectif des gélules est de sti...
Corrosion Of Copper-Base Alloys In A Geothermal Brine
Corrosion Of Copper-Base Alloys In A Geothermal Brine
Abstract
The geothermal environment and the experimental procedures and schedules for corrosion tests of copper-base procedures and schedules for corrosion tests ...
In Vitro Comparative Study of Fretting-Corrosion Resistance of Ti6Al4V and Co28Cr6Mo in a Taper Joint Subjected to High Bending Moment
In Vitro Comparative Study of Fretting-Corrosion Resistance of Ti6Al4V and Co28Cr6Mo in a Taper Joint Subjected to High Bending Moment
Co alloy modular necks have been introduced in orthopaedics to address mechanical failure of the neck-stem junction (NSJ) observed in Ti alloy dual-modular hip stem. However, follo...
Corrosion Behaviour of Additively Manufactured High Entropy Alloys
Corrosion Behaviour of Additively Manufactured High Entropy Alloys
Additive manufacturing (AM) is a modern manufacturing technique that facilitates the production of components layer by layer from CAD files, with more recent developments in the fi...
Spectral Analysis Of CO2 Corrosion Product Scales On 13Cr Tubing Steel
Spectral Analysis Of CO2 Corrosion Product Scales On 13Cr Tubing Steel
Abstract
CO2 corrosion product scales formed on 13Cr tubing steel in autoclave and in the simulated corrosion environment of oil field are investigated in the pap...
Alloy Selection for Reheater Tubes in Flue Gas Desulfurization Systems
Alloy Selection for Reheater Tubes in Flue Gas Desulfurization Systems
Abstract
Service performance of reheater systems has been less than desirable in several flue gas desulfurization (FGD) units. The selection of proper alloys for opt...
Two-dimensional numerical analysis of differential concentration corrosion in seawater pipeline
Two-dimensional numerical analysis of differential concentration corrosion in seawater pipeline
Purpose
The purpose of this paper is to develop a new two-dimensional differential concentration corrosion mathematical model based on the knowledge that oxygen distribution on the...