Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Etiologic and Audiologic Evaluations After Universal Neonatal Hearing Screening: Analysis of 170 Referred Neonates

View through CrossRef
OBJECTIVE. The goal was to clarify the audiologic aspects and causes of congenital hearing loss in children who failed universal neonatal hearing screening. METHODS. A prospective analysis of 170 consecutive records of neonates referred to a tertiary center after universal neonatal hearing screening failure, between 1998 and 2006, was performed. The data presented here represent the equivalent of ∼87000 screened newborns. The screening results were validated with a clinical ear, nose, and throat examination and electrophysiological testing, including diagnostic auditory brainstem response, automated steady state response, and/or behavioral testing. A diagnostic evaluation protocol for identification of the cause of the hearing loss was also implemented, in collaboration with the departments of genetics and pediatrics. RESULTS. Permanent hearing loss was confirmed in 116 children (68.2%). Bilateral hearing loss was diagnosed in 68 infants (58.6%) and unilateral hearing loss in 48 infants (41.4%). Median thresholds for the neonates with confirmed hearing loss were severe in both unilateral and bilateral cases, at 70 dB nHL and 80 dB nHL, respectively. In 55.8% of those cases, no risk factors for hearing loss were found. In 60.4%, the initial automated auditory brainstem response diagnosis was totally in agreement with the audiologic evaluation results. In 8.3% of the cases, however, a unilateral refer result was finally classified as bilateral hearing loss. An etiologic factor could be identified in 55.2% of the cases. Of the causes identified, a genetic mechanism was present in 60.4% of the cases, peripartal problems in 20.8%, and congenital cytomegalovirus infection in 18.8%. CONCLUSIONS. An etiologic factor could be identified for nearly one half of the children with confirmed congenital hearing loss referred through a universal hearing screening program.
Title: Etiologic and Audiologic Evaluations After Universal Neonatal Hearing Screening: Analysis of 170 Referred Neonates
Description:
OBJECTIVE.
The goal was to clarify the audiologic aspects and causes of congenital hearing loss in children who failed universal neonatal hearing screening.
METHODS.
A prospective analysis of 170 consecutive records of neonates referred to a tertiary center after universal neonatal hearing screening failure, between 1998 and 2006, was performed.
The data presented here represent the equivalent of ∼87000 screened newborns.
The screening results were validated with a clinical ear, nose, and throat examination and electrophysiological testing, including diagnostic auditory brainstem response, automated steady state response, and/or behavioral testing.
A diagnostic evaluation protocol for identification of the cause of the hearing loss was also implemented, in collaboration with the departments of genetics and pediatrics.
RESULTS.
Permanent hearing loss was confirmed in 116 children (68.
2%).
Bilateral hearing loss was diagnosed in 68 infants (58.
6%) and unilateral hearing loss in 48 infants (41.
4%).
Median thresholds for the neonates with confirmed hearing loss were severe in both unilateral and bilateral cases, at 70 dB nHL and 80 dB nHL, respectively.
In 55.
8% of those cases, no risk factors for hearing loss were found.
In 60.
4%, the initial automated auditory brainstem response diagnosis was totally in agreement with the audiologic evaluation results.
In 8.
3% of the cases, however, a unilateral refer result was finally classified as bilateral hearing loss.
An etiologic factor could be identified in 55.
2% of the cases.
Of the causes identified, a genetic mechanism was present in 60.
4% of the cases, peripartal problems in 20.
8%, and congenital cytomegalovirus infection in 18.
8%.
CONCLUSIONS.
An etiologic factor could be identified for nearly one half of the children with confirmed congenital hearing loss referred through a universal hearing screening program.

Related Results

FREQUENCY OF CONGENITAL HEARING LOSS IN NEONATES
FREQUENCY OF CONGENITAL HEARING LOSS IN NEONATES
Background:Congenital hearing loss is one of the most common neonatal sensory deficits, affecting approximately 1–3 per 1,000 live births globally. Early identification during the ...
Novel Molecular Genetic Etiology of Asymmetric Hearing Loss: Autosomal-Dominant LMX1A Variants
Novel Molecular Genetic Etiology of Asymmetric Hearing Loss: Autosomal-Dominant LMX1A Variants
Introduction: Sensorineural hearing loss is the most common sensory disorder in humans. Genetic analyses have greatly increased our understanding of the pathogenic mech...
Outcomes of Universal Neonatal Hearing Screening Program in a Tertiary Care Hospital in Lahore
Outcomes of Universal Neonatal Hearing Screening Program in a Tertiary Care Hospital in Lahore
Objective: This study aimed to assess the outcomes of a universal neonatal hearing screening program in a tertiary care hospital in Lahore.   Methods This cross-sectional study was...
Burden of treatment associated with hearing aid use among older adults with hearing loss: a qualitative study
Burden of treatment associated with hearing aid use among older adults with hearing loss: a qualitative study
Abstract Background Treatment burden can affect patients’ ability to carry out tasks or follow recommendations from healthcare providers. Evaluating the burden as...
Faktor Risiko Kematian Neonatal Di Kabupaten Timor Tengah Selatan dan Sumba Timur
Faktor Risiko Kematian Neonatal Di Kabupaten Timor Tengah Selatan dan Sumba Timur
Angka Kematian Bayi (AKB) sampai saat ini masih tinggi di Indonesia, dan Provinsi Nusa Tenggara Timur (Provinsi NTT) merupakan salah satu penyumbang tingginya AKB tersebut, paling ...
A STUDY TO DETERMINE THE ROLE OF HEMATOLOGICAL PROFILE, SCORING SYSTEM, AND CRP IN EARLY DIAGNOSIS OF NEONATAL SEPSIS
A STUDY TO DETERMINE THE ROLE OF HEMATOLOGICAL PROFILE, SCORING SYSTEM, AND CRP IN EARLY DIAGNOSIS OF NEONATAL SEPSIS
Objective: The objective of the study was to study the hematological parameters according to Rodwell’s Hematological Scoring System (HSS) in neonatal sepsis, to evaluate the effica...

Back to Top