Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Basic Study for Micro Pump Using Electroosmotic Flow

View through CrossRef
The characteristic features of electroosmotic flow have been studied to obtain important information for applying the flow to a micro pump as a driving device. Here, an electroosmotic flow of water was generated in a donut channel constructed by a gap between two parallel donut-shaped glass plates. The flow rate was measured in relation to the applied voltage, the gap width of the channel, the pressure gradient and the properties of the fluid. The experimental results were compared with a theoretical equation of electroosmosis, the Helmholtz-Smoluchowski equation, which predicts that the electroosmotic flow rate is proportional to the applied voltage as well as to the gap width. The Electroosmotic flow rate increased linearly with the applied voltage. however, there appeared some particular voltage ranges of nonlinear relation unlike the Helmholtz-Smoluchowski equation. The water properties (the conductivity and the kinds of impurities included) had a great influence on the electroosmotic flow rate characteristics including the degree of non-linearity and even the flow direction. The cause of these phenomena has not been clarified. It is conjectured that the zeta potential of the glass-water interface was altered by the applied electric field. It is confirmed that the electroosmotic flow rate is proportional to the gap size of the channel. When a pressure gradient existed in the direction of the electroosmotic flow, the total flow rate was given as a sum of the flow rates of the electroosmotic and Poiseuille flows. These findings provide important information for micro pumps. For measuring the electroosmotic flow rate, we developed a micro flow meter consisting of a capillary and two fine wires. This flow meter makes it possible to measure a flow rate the order of 1×10−3 mm3/sec (= 1 nl/sec) and has a potential ability to measure even much smaller flow rates.
Title: Basic Study for Micro Pump Using Electroosmotic Flow
Description:
The characteristic features of electroosmotic flow have been studied to obtain important information for applying the flow to a micro pump as a driving device.
Here, an electroosmotic flow of water was generated in a donut channel constructed by a gap between two parallel donut-shaped glass plates.
The flow rate was measured in relation to the applied voltage, the gap width of the channel, the pressure gradient and the properties of the fluid.
The experimental results were compared with a theoretical equation of electroosmosis, the Helmholtz-Smoluchowski equation, which predicts that the electroosmotic flow rate is proportional to the applied voltage as well as to the gap width.
The Electroosmotic flow rate increased linearly with the applied voltage.
however, there appeared some particular voltage ranges of nonlinear relation unlike the Helmholtz-Smoluchowski equation.
The water properties (the conductivity and the kinds of impurities included) had a great influence on the electroosmotic flow rate characteristics including the degree of non-linearity and even the flow direction.
The cause of these phenomena has not been clarified.
It is conjectured that the zeta potential of the glass-water interface was altered by the applied electric field.
It is confirmed that the electroosmotic flow rate is proportional to the gap size of the channel.
When a pressure gradient existed in the direction of the electroosmotic flow, the total flow rate was given as a sum of the flow rates of the electroosmotic and Poiseuille flows.
These findings provide important information for micro pumps.
For measuring the electroosmotic flow rate, we developed a micro flow meter consisting of a capillary and two fine wires.
This flow meter makes it possible to measure a flow rate the order of 1×10−3 mm3/sec (= 1 nl/sec) and has a potential ability to measure even much smaller flow rates.

Related Results

Drying of a porous layer in an external constant electric field (electroosmotic drying)
Drying of a porous layer in an external constant electric field (electroosmotic drying)
In this Chapter, mathematical modeling of the drying process of a porous layer under the influence of an external constant electric field is presented, taking into account the elec...
The influence of micro influencers and digital marketing on product purchasing decisions at tiktok shop in bengkulu city
The influence of micro influencers and digital marketing on product purchasing decisions at tiktok shop in bengkulu city
THE INFLUENCE OF MICRO-INFLUENCERS AND DIGITAL MARKETING ON PURCHASE DECISIONS OF TIKTOK SHOP CUSTOMERS IN BENGKULU CITY Andhes Tiani Putri, Meylaty F   12Faculty Of Economic E...
Downhole Beam Pump Operation: Slippage and Buckling Forces Transmitted to the Rod String
Downhole Beam Pump Operation: Slippage and Buckling Forces Transmitted to the Rod String
Abstract New results for downhole beam or rod pumps, from fairly recent test data are in conflict with traditional relationships. Additional testing is in progres...
Downhole Beam Pump Operation: Slippage and Buckling Forces Transmitted to the Rod String
Downhole Beam Pump Operation: Slippage and Buckling Forces Transmitted to the Rod String
Abstract New results for downhole beam or rod pumps from fairly recent test data are in conflict with traditional relationships. Additional testing is in progress...
Modification of a Radial Pump Characteristics With Fluid Suction in the Vaneless Space
Modification of a Radial Pump Characteristics With Fluid Suction in the Vaneless Space
Abstract Flow instability is a common unsteady phenomenon in the field of turbomachinery that often causes large pressure fluctuations, performance penalties, and st...
Series multi-blood pump with dual activation for pediatric patients with heart failure
Series multi-blood pump with dual activation for pediatric patients with heart failure
Pediatric heart failure (HF), arising from both congenital and acquired disorders, is a serious pathology that affects thousands of children each year. Severe cases of pediatric HF...
Modeling and Optimal Control of a Variable-Speed Centrifugal Pump With a Pipeline
Modeling and Optimal Control of a Variable-Speed Centrifugal Pump With a Pipeline
Pumping processes often require different operating conditions for the same pipeline. The conditions downstream in the pipeline can change in such a way that the pressure at the di...
New Solutions for Installation of Sucker Rod Pumps in Marginal Field
New Solutions for Installation of Sucker Rod Pumps in Marginal Field
Abstract This paper uses case studies to showcase the techno-economic impact of insert anchor and portable foundation on the development of marginal fields. Case stu...