Complementary Fourier Single-Pixel Imaging

View through CrossRef
Single-pixel imaging, with the advantages of a wide spectrum, beyond-visual-field imaging, and robustness to light scattering, has attracted increasing attention in recent years. Fourier single-pixel imaging (FSI) can reconstruct sharp images under sub-Nyquist sampling. However, the conventional FSI has difficulty balancing imaging quality and efficiency. To overcome this issue, we proposed a novel approach called complementary Fourier single-pixel imaging (CFSI) to reduce the number of measurements while retaining its robustness. The complementary nature of Fourier patterns based on a four-step phase-shift algorithm is combined with the complementary nature of a digital micromirror device. CFSI only requires two phase-shifted patterns to obtain one Fourier spectral value. Four light intensity values are obtained by loading the two patterns, and the spectral value is calculated through differential measurement, which has good robustness to noise. The proposed method is verified by simulations and experiments compared with FSI based on two-, three-, and four-step phase shift algorithms. CFSI performed better than the other methods under the condition that the best imaging quality of CFSI is not reached. The reported technique provides an alternative approach to realize real-time and high-quality imaging.
Title: Complementary Fourier Single-Pixel Imaging
Description:
Single-pixel imaging, with the advantages of a wide spectrum, beyond-visual-field imaging, and robustness to light scattering, has attracted increasing attention in recent years.
Fourier single-pixel imaging (FSI) can reconstruct sharp images under sub-Nyquist sampling.
However, the conventional FSI has difficulty balancing imaging quality and efficiency.
To overcome this issue, we proposed a novel approach called complementary Fourier single-pixel imaging (CFSI) to reduce the number of measurements while retaining its robustness.
The complementary nature of Fourier patterns based on a four-step phase-shift algorithm is combined with the complementary nature of a digital micromirror device.
CFSI only requires two phase-shifted patterns to obtain one Fourier spectral value.
Four light intensity values are obtained by loading the two patterns, and the spectral value is calculated through differential measurement, which has good robustness to noise.
The proposed method is verified by simulations and experiments compared with FSI based on two-, three-, and four-step phase shift algorithms.
CFSI performed better than the other methods under the condition that the best imaging quality of CFSI is not reached.
The reported technique provides an alternative approach to realize real-time and high-quality imaging.

Related Results

Introduction
Introduction
Jean Baptiste Joseph Fourier’s powerful idea of decomposition of a signal into sinusoidal components has found application in almost every engineering and science field. An incompl...
Ringing-free fast Fourier single-pixel imaging
Ringing-free fast Fourier single-pixel imaging
Fourier single-pixel imaging (FSI) allows an image to be reconstructed by acquiring the Fourier spectrum of the image using a single-pixel detector. Fast FSI is typically achieved ...
Quantum imaging with optical fibre structures
Quantum imaging with optical fibre structures
(English) Two-photon quantum correlations are a resource for quantum communication, sensing, and imaging. Coincidence-based quantum imaging leverages spatiotemporal quantum correla...
Image-free active autofocusing with dual modulation and its application to Fourier single-pixel imaging
Image-free active autofocusing with dual modulation and its application to Fourier single-pixel imaging
Autofocusing is widely used in applications where sharp image acquisition or projection is needed. Here we report an active autofocusing method that works with wide-field structure...
Image-free active autofocusing with dual modulation and its application to Fourier single-pixel imaging
Image-free active autofocusing with dual modulation and its application to Fourier single-pixel imaging
Autofocusing is widely used in applications where sharp image acquisition or projection is needed. Here we report an active autofocusing method that works with wide-field structure...
Imaging biological tissue with high-throughput single-pixel compressive holography
Imaging biological tissue with high-throughput single-pixel compressive holography
Abstract Single-pixel holography (SPH) is capable of generating holographic images with rich spatial information by employing only a single-pixel detector. Thanks to the re...
P‐126: An Introduction to GGRB Virtual Pixel Technology
P‐126: An Introduction to GGRB Virtual Pixel Technology
The constructions of the GGRB virtual pixel and the effect on the display performance are introduced by comparing with that of the Diamond RGBG virtual pixel, a typical virtual pix...
Uniform Sampling Method with Optimized VLSI Circuit for Data Augmentation in Pixel Detector
Uniform Sampling Method with Optimized VLSI Circuit for Data Augmentation in Pixel Detector
The Uniform Sampling Method combined with an optimized VLSI circuit offers an efficient approach to data augmentation in pixel detectors. This method ensures uniform coverage of pi...

Back to Top