Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

The Impacts of the Sterilization Method and the Electrospinning Conditions of Nanofibrous Biodegradable Layers on Their Degradation and Hemocompatibility Behavior

View through CrossRef
The use of electrospun polymeric biodegradable materials for medical applications is becoming increasingly widespread. One of the most important parameters regarding the functionality of nanofiber scaffolds during implantation and the subsequent regeneration of damaged tissues concerns their stability and degradation behavior, both of which are influenced by a wide range of factors (the properties of the polymer and the polymer solution, the technological processing approach, the sterilization method, etc.). This study monitored the degradation of nanofibrous materials fabricated from degradable polyesters as a result of the sterilization method applied (ethylene oxide and gamma irradiation) and the solvent system used to prepare the spun polymer solution. Aliphatic polyesters PCL and PLCL were chosen for this study and selected with respect to the applicability and handling in the surgical setting of these nanofibrous materials for vascular bandaging. The results revealed that the choice of solvent system exerts a significant impact on degradation during sterilization, especially at higher gamma irradiation values. The subsequent enzyme-catalyzed degradation of the materials following sterilization indicated that the choice of the sterilization method influenced the degradation behavior of the materials. Whereas wave-like degradation was evident concerning ethylene oxide sterilization, no such behavior was observed following gamma-irradiation sterilization. With concern for some of the tested materials, the results also indicated the potential for influencing the development of degradation within the bulk versus degradation from the surface of the material. Both the sterilization method and the choice of the spinning solvent system were found to impact degradation, which was observed to be most accelerated in the case of PLCL (L-lactide-co-caprolactone copolymer) electrospun from organic acids and subsequently sterilized using gamma irradiation. Since we planned to use these materials in cardiovascular applications, it was decided that their hemocompatibility would also be tested. The results of these tests revealed that changes in the structures of the materials initiated by sterilization may exert thrombogenic and anticoagulant impacts. Moreover, the microscopic analysis suggested that the solvent system used in the preparation of the materials potentially affects the behavior of erythrocytes; however, no indication of the occurrence of hemolysis was detected.
Title: The Impacts of the Sterilization Method and the Electrospinning Conditions of Nanofibrous Biodegradable Layers on Their Degradation and Hemocompatibility Behavior
Description:
The use of electrospun polymeric biodegradable materials for medical applications is becoming increasingly widespread.
One of the most important parameters regarding the functionality of nanofiber scaffolds during implantation and the subsequent regeneration of damaged tissues concerns their stability and degradation behavior, both of which are influenced by a wide range of factors (the properties of the polymer and the polymer solution, the technological processing approach, the sterilization method, etc.
).
This study monitored the degradation of nanofibrous materials fabricated from degradable polyesters as a result of the sterilization method applied (ethylene oxide and gamma irradiation) and the solvent system used to prepare the spun polymer solution.
Aliphatic polyesters PCL and PLCL were chosen for this study and selected with respect to the applicability and handling in the surgical setting of these nanofibrous materials for vascular bandaging.
The results revealed that the choice of solvent system exerts a significant impact on degradation during sterilization, especially at higher gamma irradiation values.
The subsequent enzyme-catalyzed degradation of the materials following sterilization indicated that the choice of the sterilization method influenced the degradation behavior of the materials.
Whereas wave-like degradation was evident concerning ethylene oxide sterilization, no such behavior was observed following gamma-irradiation sterilization.
With concern for some of the tested materials, the results also indicated the potential for influencing the development of degradation within the bulk versus degradation from the surface of the material.
Both the sterilization method and the choice of the spinning solvent system were found to impact degradation, which was observed to be most accelerated in the case of PLCL (L-lactide-co-caprolactone copolymer) electrospun from organic acids and subsequently sterilized using gamma irradiation.
Since we planned to use these materials in cardiovascular applications, it was decided that their hemocompatibility would also be tested.
The results of these tests revealed that changes in the structures of the materials initiated by sterilization may exert thrombogenic and anticoagulant impacts.
Moreover, the microscopic analysis suggested that the solvent system used in the preparation of the materials potentially affects the behavior of erythrocytes; however, no indication of the occurrence of hemolysis was detected.

Related Results

Forced Sterilization
Forced Sterilization
Photo by Renè Müller on Unsplash INTRODUCTION Forced sterilization of women around the globe is a human rights violation and bioethical concern. In the past, countries enacted laws...
Pregnancy after Tubal Sterilization
Pregnancy after Tubal Sterilization
Objectives: In our study, we have tried to evaluate the causative factors for sterilization failure and also to discuss preventive measures to avoid maternal morbidities and unwant...
Obstetric Outcomes After Failed Hysteroscopic and Laparoscopic Sterilization Procedures
Obstetric Outcomes After Failed Hysteroscopic and Laparoscopic Sterilization Procedures
OBJECTIVE: To compare obstetric outcomes after failed hysteroscopic and laparoscopic sterilization. METHODS: This retrospe...
STERILIZATION: A PREREQUISITE IN MEDICAL DIAGNOSTICS
STERILIZATION: A PREREQUISITE IN MEDICAL DIAGNOSTICS
Sterilization is a critical process with wide-ranging applications in healthcare, pharmaceuticals, food production, and laboratory research. Its primary objective is the complete e...
Fabrication of three-dimensional nanofibrous macrostructures by electrospinning
Fabrication of three-dimensional nanofibrous macrostructures by electrospinning
Electrospinning has been widely used in fabricating nanofibers and nanofibrous membranes. Recently, the fabrication of three-dimensional (3D) nanofibrous macrostructures has become...
Gynecologic Outcomes After Hysteroscopic and Laparoscopic Sterilization Procedures
Gynecologic Outcomes After Hysteroscopic and Laparoscopic Sterilization Procedures
OBJECTIVE: To compare rates of gynecologic morbidity after laparoscopic and hysteroscopic sterilization. METHODS: This ret...

Back to Top