Maps of long-term soiling losses in Europe considering a partial cleaning effect by rain

View through CrossRef
The soiling of PV modules has been estimated to yield global losses in the solar energy production by 4 to 7%, even considering the cleaning efforts in many solar energy systems. Despite this, soiling measurements are not always available, making models particularly valuable for estimating these losses. However, soiling models currently present two limitations: most of them assume that daily rain accumulations higher than a threshold value can totally clean PV modules and, additionally, that rain will have the same washing effect on all types of soiling, independently of their higher or lower adherent properties. In this work, the HSU model (Coello and Boyle, 2019) is modified to include the two aforementioned effects. The original and modified HSU models are then calibrated for two locations in Africa where observations of long-term soiling losses were available. At the first considered location, the predominant soiling type was mainly washable by rain but showed the partial cleaning effects, while at the second location, despite the frequent and abundant rainfall, the build-up of persistent soiling was observed. The calibrated parameters for the original and modified HSU models were then applied to reanalysis meteorological 2-dimensional input data to estimate the associated soiling losses in Europe for a 20-yr operation without any artificial cleaning. The application of model parameters derived for the African sites for Europe is considered to be valid for the demonstration of the method and delivers exemplary results that might also occur for soiling types found at some European sites. The derived different soiling maps should, however, not be understood as the most likely possible values for European soiling. When considering the exemplary removable soiling type, the original HSU model underestimates on average the European soiling losses by a factor of 4 compared to the estimations of the modified HSU model. When considering the exemplary persistent soiling type, the European soiling losses estimated with the modified HSU model are on average 5.5 times larger than those estimated with the original HSU model. Additionally, the European soiling losses estimated with the modified HSU model considering a persistent soiling type are 2.4 times larger than those considering a removable soiling type, which highlights not only the importance of properly modeling the soiling losses but also of choosing the correct soiling type. The results show that, at least for some soiling types, mechanical cleaning of the PV modules is necessary to avoid high soiling losses even in rainy regions such as Central Europe.
Title: Maps of long-term soiling losses in Europe considering a partial cleaning effect by rain
Description:
The soiling of PV modules has been estimated to yield global losses in the solar energy production by 4 to 7%, even considering the cleaning efforts in many solar energy systems.
Despite this, soiling measurements are not always available, making models particularly valuable for estimating these losses.
However, soiling models currently present two limitations: most of them assume that daily rain accumulations higher than a threshold value can totally clean PV modules and, additionally, that rain will have the same washing effect on all types of soiling, independently of their higher or lower adherent properties.
In this work, the HSU model (Coello and Boyle, 2019) is modified to include the two aforementioned effects.
The original and modified HSU models are then calibrated for two locations in Africa where observations of long-term soiling losses were available.
At the first considered location, the predominant soiling type was mainly washable by rain but showed the partial cleaning effects, while at the second location, despite the frequent and abundant rainfall, the build-up of persistent soiling was observed.
The calibrated parameters for the original and modified HSU models were then applied to reanalysis meteorological 2-dimensional input data to estimate the associated soiling losses in Europe for a 20-yr operation without any artificial cleaning.
The application of model parameters derived for the African sites for Europe is considered to be valid for the demonstration of the method and delivers exemplary results that might also occur for soiling types found at some European sites.
The derived different soiling maps should, however, not be understood as the most likely possible values for European soiling.
When considering the exemplary removable soiling type, the original HSU model underestimates on average the European soiling losses by a factor of 4 compared to the estimations of the modified HSU model.
When considering the exemplary persistent soiling type, the European soiling losses estimated with the modified HSU model are on average 5.
5 times larger than those estimated with the original HSU model.
Additionally, the European soiling losses estimated with the modified HSU model considering a persistent soiling type are 2.
4 times larger than those considering a removable soiling type, which highlights not only the importance of properly modeling the soiling losses but also of choosing the correct soiling type.
The results show that, at least for some soiling types, mechanical cleaning of the PV modules is necessary to avoid high soiling losses even in rainy regions such as Central Europe.

Related Results

Effect of non-uniform soiling on solar panel output and revenue analyzed through controlled experiment
Effect of non-uniform soiling on solar panel output and revenue analyzed through controlled experiment
Non-uniform soiling drastically decreases the power generation of PV panels. Different events are responsible for the non-uniform soiling on PV panels for example bird droppings, s...
Painful Defecation and Fecal Soiling in Children
Painful Defecation and Fecal Soiling in Children
Fecal soiling is a common complaint among school-age children. The fecal soiling is often accompanied by chronic constipation and so-called "idiopathic," "functional," or "psychoge...
Aerial Imaging-Based Soiling Detection System for Solar Photovoltaic Panel Cleanliness Inspection
Aerial Imaging-Based Soiling Detection System for Solar Photovoltaic Panel Cleanliness Inspection
Unmanned Aerial Vehicles (UAVs) integrated with lightweight visual cameras hold significant promise in renewable energy asset inspection and monitoring. This study presents an AI-a...
The Impact of Soiling on PV Module Performance in Saudi Arabia
The Impact of Soiling on PV Module Performance in Saudi Arabia
Solar photovoltaic (PV) deployment is rapidly expanding around the world. However, the soiling factor has an impact on its performance. Saudi Arabia has high solar irradiation and ...
Implementation of glass-curtain-wall cleaning robot driven by double flexible rope
Implementation of glass-curtain-wall cleaning robot driven by double flexible rope
Purpose – The purpose of this paper is to implement a glass-curtain-wall cleaning robot driven by a double flexible rope, so as to replace manual cleaning. The glas...
Why Does the PV Solar Power Plant Operate Ineffectively?
Why Does the PV Solar Power Plant Operate Ineffectively?
Quality, reliability, and durability are the key features of photovoltaic (PV) solar system design, production, and operation. They are considered when manufacturing every cell and...
Evaluation of Selected Amateur Rain Gauges with Hellmann Rain Gauge Measurements
Evaluation of Selected Amateur Rain Gauges with Hellmann Rain Gauge Measurements
The paper compares precipitation measurements from the Stratus manual rain gauge from the CoCoRaHS network and two Davis Vantage Vue and Davis Vantage Pro 2A rain gauges with the H...
A Historical-Theological Understanding of the “Latter Rain”
A Historical-Theological Understanding of the “Latter Rain”
This study is a historical-theological analysis of the understanding of the “Latter Rain” developed in the 19th and 20th centuries. The understanding of the Latter Rain stems from ...

Back to Top