Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Method to Determine the Standard Deviation of SUV Parameters

View through CrossRef
Abstract Some of the parameters used for the quantification of Positron Emission Tomography (PET) images are the Standardized Uptake Value (SUV)Max, SUV Mean and SUV Peak. In order to assess the significance of an increasing or decreasing of these parameters for diagnostic purposes it is relevant to determine their standard deviation. In this study we present a method to determine the range of statistical variation of the SUV in PET images. Our method is based on dividing an original dataset into subsets of shorter time-frames. The variation between the SUV parameters of the subsets is used to estimate the standard deviation of the of the original acquisition. This method was tested on images of a NEMA quality phantom with acquisition time of 150 s per bed position and foreground to background activity ratio of F18-2-fluoro-2-deoxy-D-glucose (FDG) of 10:1. This original dataset has been reconstructed with different reconstruction lengths, generating new data subsets. The SUV Max, Mean and Peak were calculated for each image in the subsets. Their standard deviation has been calculated per subset for the different spheres included in the phantom. The variation of each subset has then been used to estimate the expected variation between images at 150 s reconstruction length. We report the largest standard deviation of the SUV parameters for the smallest sphere, and the smallest variation for the largest sphere. The expected variation at 150 s reconstruction length does not exceed 6% for the smallest sphere and 2% for the largest sphere, but we report an higher coefficient of variation (up to 30%) for shorter reconstruction lengths. We also report significant differences in the variation of SUV parameters for the larger spheres. With the presented method we are able to determine the standard deviation of SUV parameters only due to and the statistical variation. The method enables us to evaluate the effect of parameter selection and lesion size on the standard deviation, and therefore to evaluate its relevance on the total variation of the SUV value between studies.
Springer Science and Business Media LLC
Title: Method to Determine the Standard Deviation of SUV Parameters
Description:
Abstract Some of the parameters used for the quantification of Positron Emission Tomography (PET) images are the Standardized Uptake Value (SUV)Max, SUV Mean and SUV Peak.
In order to assess the significance of an increasing or decreasing of these parameters for diagnostic purposes it is relevant to determine their standard deviation.
In this study we present a method to determine the range of statistical variation of the SUV in PET images.
Our method is based on dividing an original dataset into subsets of shorter time-frames.
The variation between the SUV parameters of the subsets is used to estimate the standard deviation of the of the original acquisition.
This method was tested on images of a NEMA quality phantom with acquisition time of 150 s per bed position and foreground to background activity ratio of F18-2-fluoro-2-deoxy-D-glucose (FDG) of 10:1.
This original dataset has been reconstructed with different reconstruction lengths, generating new data subsets.
The SUV Max, Mean and Peak were calculated for each image in the subsets.
Their standard deviation has been calculated per subset for the different spheres included in the phantom.
The variation of each subset has then been used to estimate the expected variation between images at 150 s reconstruction length.
We report the largest standard deviation of the SUV parameters for the smallest sphere, and the smallest variation for the largest sphere.
The expected variation at 150 s reconstruction length does not exceed 6% for the smallest sphere and 2% for the largest sphere, but we report an higher coefficient of variation (up to 30%) for shorter reconstruction lengths.
We also report significant differences in the variation of SUV parameters for the larger spheres.
With the presented method we are able to determine the standard deviation of SUV parameters only due to and the statistical variation.
The method enables us to evaluate the effect of parameter selection and lesion size on the standard deviation, and therefore to evaluate its relevance on the total variation of the SUV value between studies.

Related Results

Method to determine the standard deviation of SUV parameters
Method to determine the standard deviation of SUV parameters
Abstract Some of the parameters used for the quantification of PET images are the Standardized Uptake Value (SUV)Max, SUVMean and SUVPeak. In order to assess the significan...
Assessment of Hormone Receptor Profile in Breast Cancer Using 18F‐Fluro‐Estradiol PET CT: A Pilot Study
Assessment of Hormone Receptor Profile in Breast Cancer Using 18F‐Fluro‐Estradiol PET CT: A Pilot Study
Hormone Receptor (HR) status has vital implications in prognosis and therapy of breast cancer. Currently, HR status is assessed by immunohistochemistry (IHC) of core needle biopsy ...
Method to Determine the Statistical Technical Variability of SUV Parameters
Method to Determine the Statistical Technical Variability of SUV Parameters
Abstract Background: Some of the parameters used for the quantification of Positron Emission Tomography (PET) images are the Standardized Uptake Value (SUV)Max, SUVMean and...
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Objective: To determine the frequency of common chromosomal aberrations in local population idiopathic determine the frequency of common chromosomal aberrations in local population...
Dual Time Point Positron Emission Tomography Imaging in the Head and Neck
Dual Time Point Positron Emission Tomography Imaging in the Head and Neck
ObjectiveDual time point 18F‐fluorodeoxyglucose‐positron emission tomography (DTP‐PET) is a new modality which may detect malignancy more accurately than standard PET/CT. Our main ...

Back to Top