A Novel Computational Approach to Assess Microcirculatory Resistance for assessing microcirculatory resistance in patients with non-obstructed vessels
View through CrossRef
Abstract
Background
An intracoronary wire equipped with a transducer and at least 3 to 4 ml of room-temperature saline injected into the coronary artery during prolonged congestion are often used to assess the index of microcirculatory resistance (IMR). This is a time-consuming and expensive procedure.
Methods
With the invasive wire-based IMR serving as the reference standard, this prospective, single-center, randomized study aims to evaluate the diagnostic performance of the novel single-view, pressure-wire- and adenosine-free angiographic microvascular resistance (AMR) index in patients with suspected myocardial ischemia and nonobstructive coronary arteries.
AMR was blindedly and independently computed from the diagnostic coronary angiography. An independent core laboratory determined AMR on-site in real-time and compared it blindly to wire-based IMR, interpreting wire-based IMR of ≥25 units as abnormal coronary microcirculatory resistance. The main outcome, measured against wire-based IMR as a reference, was AMR's diagnostic accuracy.
Using pressure wire-based IMR, 200 patients (200 vessels) were studied. The criteria for microvascular dysfunction (CMD) was IMR ≥ 25. AMR was blindedly and independently computed from the diagnostic coronary angiography.
Results
The mean AMR was 2.44±0.68 and showed good correlation (r = 0.6672, p < 0.001) with IMR. A least-squares fit shows a relationship: AMR=1.8+0.024 IMR (regression coefficient 95% CI: 0.011-0.037, P=0.001). According to microcirculatory status, Two groups were divided: low IMR (<25 U, non-CMD group) and high IMR (≥25 U, CMD group). AMR values were found to be significantly higher in the CMD group than in the non-CMD group (2.78±0.68 vs 2.03±0.40,P=0.004).The AUC for the diagnosis of CMD by ROC curve analysis of AMR was 0.889 (95% CI: 0.707-1.0).
Conclusion
AMR derived from angiographic views is a viable computational alternative to pressure line-based IMR, with good diagnostic accuracy in the assessment of CMD.
Springer Science and Business Media LLC
Title: A Novel Computational Approach to Assess Microcirculatory Resistance for assessing microcirculatory resistance in patients with non-obstructed vessels
Description:
Abstract
Background
An intracoronary wire equipped with a transducer and at least 3 to 4 ml of room-temperature saline injected into the coronary artery during prolonged congestion are often used to assess the index of microcirculatory resistance (IMR).
This is a time-consuming and expensive procedure.
Methods
With the invasive wire-based IMR serving as the reference standard, this prospective, single-center, randomized study aims to evaluate the diagnostic performance of the novel single-view, pressure-wire- and adenosine-free angiographic microvascular resistance (AMR) index in patients with suspected myocardial ischemia and nonobstructive coronary arteries.
AMR was blindedly and independently computed from the diagnostic coronary angiography.
An independent core laboratory determined AMR on-site in real-time and compared it blindly to wire-based IMR, interpreting wire-based IMR of ≥25 units as abnormal coronary microcirculatory resistance.
The main outcome, measured against wire-based IMR as a reference, was AMR's diagnostic accuracy.
Using pressure wire-based IMR, 200 patients (200 vessels) were studied.
The criteria for microvascular dysfunction (CMD) was IMR ≥ 25.
AMR was blindedly and independently computed from the diagnostic coronary angiography.
Results
The mean AMR was 2.
44±0.
68 and showed good correlation (r = 0.
6672, p < 0.
001) with IMR.
A least-squares fit shows a relationship: AMR=1.
8+0.
024 IMR (regression coefficient 95% CI: 0.
011-0.
037, P=0.
001).
According to microcirculatory status, Two groups were divided: low IMR (<25 U, non-CMD group) and high IMR (≥25 U, CMD group).
AMR values were found to be significantly higher in the CMD group than in the non-CMD group (2.
78±0.
68 vs 2.
03±0.
40,P=0.
004).
The AUC for the diagnosis of CMD by ROC curve analysis of AMR was 0.
889 (95% CI: 0.
707-1.
0).
Conclusion
AMR derived from angiographic views is a viable computational alternative to pressure line-based IMR, with good diagnostic accuracy in the assessment of CMD.
Related Results
Common Microcirculatory Framework for Monitoring Integrated Microcirculation
Common Microcirculatory Framework for Monitoring Integrated Microcirculation
Abstract
Wide variation in magnitudes, units, and ranges of the microcirculatory variables brings hindrance in describing and evaluating the integrated microcirculatory fun...
Vessels from Late Medieval cemeteries in the Central Balkans
Vessels from Late Medieval cemeteries in the Central Balkans
Although a rare occurrence in late medieval cemeteries, vessels have been
found on almost all major sites of the period, such as Novo Brdo, Trgoviste,
Reljina Gradina and the...
Evolution of Antimicrobial Resistance in Community vs. Hospital-Acquired Infections
Evolution of Antimicrobial Resistance in Community vs. Hospital-Acquired Infections
Abstract
Introduction
Hospitals are high-risk environments for infections. Despite the global recognition of these pathogens, few studies compare microorganisms from community-acqu...
Determinants of obstructed labour and its adverse outcomes among women who gave birth in Hawassa University referral Hospital: A case-control study
Determinants of obstructed labour and its adverse outcomes among women who gave birth in Hawassa University referral Hospital: A case-control study
Background
Globally, obstructed labour accounted for 22% of maternal morbidities and up to 70% of perinatal deaths. It is one of the most common preventable causes of maternal and ...
A STUDY ON OBSTRUCTED LABOUR-STILL A LIFE THREATENING CATASTROPHE IN MODERN OBSTETRICS
A STUDY ON OBSTRUCTED LABOUR-STILL A LIFE THREATENING CATASTROPHE IN MODERN OBSTETRICS
Background : Approximately 8% of all the maternal deaths in developing countries are due to obstructed
labour.Neglected Obstructed Labour is a major cause of both maternal and neon...
Autonomy on Trial
Autonomy on Trial
Photo by CHUTTERSNAP on Unsplash
Abstract
This paper critically examines how US bioethics and health law conceptualize patient autonomy, contrasting the rights-based, individualist...
Sublingual capillary de-recruitment with preserved recruitability in resuscitated patients with circulatory shock
Sublingual capillary de-recruitment with preserved recruitability in resuscitated patients with circulatory shock
Abstract
Background
Circulatory shock and multi-organ failure remain major contributors to mortality in critically ill patients, resulting in decoupling of macro- and micr...
Obstructed labor and associated factors among laboring women, Northeast Ethiopia.
Obstructed labor and associated factors among laboring women, Northeast Ethiopia.
Introduction: Obstructed labor is still the major cause of maternal
morbidity and mortality, and adverse birth outcomes in low-income
countries. This study aims to assess obstructe...