Javascript must be enabled to continue!
Coalescence of Bubbles Translating through a Tube
View through CrossRef
Abstract: The results of an experimental study of the interaction and coalescence of two air bubbles translating in a cylindrical tube are presented. Both pressure‐ and buoyancy‐driven motion of the two bubbles in a Newtonian suspending fluid within the tube are considered. The close approach of the two bubbles is examined using image analysis, and measurements of the coalescence time are reported for various bubble size ratios and capillary numbers. For pressure‐driven motion of bubbles, coalescence is found to occur in an axisymmetric configuration for all bubble size ratios considered in the experiments. For buoyancy‐driven motion, on the other hand, the disturbance flow behind the leading bubble causes the trailing bubble to move radially out toward the tube wall when the trailing bubble size becomes very small compared to the size of the leading bubble. In that case, coalescence occurs in a nonaxisymmetric configuration, with a time scale for coalescence that is substantially larger than that for coalescence in the axisymmetric configuration. When the imposed flow is in the direction of the buoyancy force, coalescence time is independent of bubble size ratio, and decreases as the capillary number increases. Experimental measurements of the radius of the thin liquid film separating the two bubbles are used in conjunction with a simple film drainage model to predict the dependence of the coalescence time on the bubble size ratio.
Title: Coalescence of Bubbles Translating through a Tube
Description:
Abstract: The results of an experimental study of the interaction and coalescence of two air bubbles translating in a cylindrical tube are presented.
Both pressure‐ and buoyancy‐driven motion of the two bubbles in a Newtonian suspending fluid within the tube are considered.
The close approach of the two bubbles is examined using image analysis, and measurements of the coalescence time are reported for various bubble size ratios and capillary numbers.
For pressure‐driven motion of bubbles, coalescence is found to occur in an axisymmetric configuration for all bubble size ratios considered in the experiments.
For buoyancy‐driven motion, on the other hand, the disturbance flow behind the leading bubble causes the trailing bubble to move radially out toward the tube wall when the trailing bubble size becomes very small compared to the size of the leading bubble.
In that case, coalescence occurs in a nonaxisymmetric configuration, with a time scale for coalescence that is substantially larger than that for coalescence in the axisymmetric configuration.
When the imposed flow is in the direction of the buoyancy force, coalescence time is independent of bubble size ratio, and decreases as the capillary number increases.
Experimental measurements of the radius of the thin liquid film separating the two bubbles are used in conjunction with a simple film drainage model to predict the dependence of the coalescence time on the bubble size ratio.
Related Results
Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract
Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
Analysis of Partial Electrocoalescence by Level-Set and Finite Element Methods
Analysis of Partial Electrocoalescence by Level-Set and Finite Element Methods
The coalescence of a water drop in a dieletric oil phase at a water layer interface in the presence of an electric field is simulated by solving the Navier-Stokes and charge conser...
Medical bubbles
Medical bubbles
Ultrasound contrast agents consist of gas bubbles with equilibrium radii to . These medical bubbles are small enough to be transported intravascularly and to pass through capillary...
Bubble trapping and coalescence at the baffles in stirred tank reactors
Bubble trapping and coalescence at the baffles in stirred tank reactors
AbstractTurbulent flow and bubble coalescence in water at the leeward side of a baffle in a stirred tank reactor have been studied with PIV and a high‐speed CCD camera. A large sta...
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
EnvironmentalSurveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) This comprehensive protocol suite enables systematic environmental surveillance for avian influenza...
Scattering of Sound by Gas Bubbles in Water and Sediments
Scattering of Sound by Gas Bubbles in Water and Sediments
ABSTRACT
In this paper, a self-consistent multiple scattering approach with suitable pair-correlation function is employed to study acoustic wave propagation thro...
On a Study of Flow Past Non-Newtonian Fluid Bubbles
On a Study of Flow Past Non-Newtonian Fluid Bubbles
In the current work, we aim at finding an analytical solution to the problem of fluid flow past a pair of separated non-Newtonian fluid bubbles. These bubbles are assumed to be sph...
Charged Cavitation Multibubbles Dynamics Model: Growth Process
Charged Cavitation Multibubbles Dynamics Model: Growth Process
The nonlinear dynamics of charged cavitation bubbles are investigated theoretically and analytically in this study through the Rayleigh–Plesset model in dielectric liquids. The phy...

