Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Caffeine Ingestion Decreases Glucose Disposal During a Hyperinsulinemic-Euglycemic Clamp in Sedentary Humans

View through CrossRef
The purpose of this investigation was to examine the effect of caffeine (an adenosine receptor antagonist) on whole-body insulin-mediated glucose disposal in resting humans. We hypothesized that glucose disposal would be lower after the administration of caffeine compared with placebo. Healthy, lean, sedentary (n = 9) men underwent two trial sessions, one after caffeine administration (5 mg/kg body wt) and one after placebo administration (dextrose) in a double-blind randomized design. Glucose disposal was assessed using a hyperinsulinemic-euglycemic clamp. Before the clamp, there were no differences in circulating levels of methylxanthines, catecholamines, or glucose. Euglycemia was maintained throughout the clamp with no difference in plasma glucose concentrations between trials. The insulin concentrations were also similar in the caffeine and placebo trials. After caffeine administration, glucose disposal was 6.38 ± 0.76 mg/kg body wt compared with 8.42 ± 0.63 mg/kg body wt after the placebo trial. This represents a significant (P < 0.05) decrease (24%) in glucose disposal after caffeine ingestion. In addition, carbohydrate storage was 35% lower (P < 0.05) in the caffeine trial than in the placebo trial. Furthermore, even when the difference in glucose disposal was normalized between the trials, there was a 23% difference in the amount of carbohydrate stored after caffeine administration compared with placebo administration. Caffeine ingestion also resulted in higher plasma epinephrine levels than placebo ingestion (P < 0.05). These data support our hypothesis that caffeine ingestion decreases glucose disposal and suggests that adenosine plays a role in regulating glucose disposal in resting humans.
Title: Caffeine Ingestion Decreases Glucose Disposal During a Hyperinsulinemic-Euglycemic Clamp in Sedentary Humans
Description:
The purpose of this investigation was to examine the effect of caffeine (an adenosine receptor antagonist) on whole-body insulin-mediated glucose disposal in resting humans.
We hypothesized that glucose disposal would be lower after the administration of caffeine compared with placebo.
Healthy, lean, sedentary (n = 9) men underwent two trial sessions, one after caffeine administration (5 mg/kg body wt) and one after placebo administration (dextrose) in a double-blind randomized design.
Glucose disposal was assessed using a hyperinsulinemic-euglycemic clamp.
Before the clamp, there were no differences in circulating levels of methylxanthines, catecholamines, or glucose.
Euglycemia was maintained throughout the clamp with no difference in plasma glucose concentrations between trials.
The insulin concentrations were also similar in the caffeine and placebo trials.
After caffeine administration, glucose disposal was 6.
38 ± 0.
76 mg/kg body wt compared with 8.
42 ± 0.
63 mg/kg body wt after the placebo trial.
This represents a significant (P < 0.
05) decrease (24%) in glucose disposal after caffeine ingestion.
In addition, carbohydrate storage was 35% lower (P < 0.
05) in the caffeine trial than in the placebo trial.
Furthermore, even when the difference in glucose disposal was normalized between the trials, there was a 23% difference in the amount of carbohydrate stored after caffeine administration compared with placebo administration.
Caffeine ingestion also resulted in higher plasma epinephrine levels than placebo ingestion (P < 0.
05).
These data support our hypothesis that caffeine ingestion decreases glucose disposal and suggests that adenosine plays a role in regulating glucose disposal in resting humans.

Related Results

British Food Journal Volume 46 Issue 12 1944
British Food Journal Volume 46 Issue 12 1944
1. The Committee have received a request from the Tea and Coffee Division for advice as to appropriate standards for liquid “coffee essences” including coffee and chicory essences,...
Comparison of the [13C]Glucose Breath Test to the Hyperinsulinemic-Euglycemic Clamp When Determining Insulin Resistance
Comparison of the [13C]Glucose Breath Test to the Hyperinsulinemic-Euglycemic Clamp When Determining Insulin Resistance
OBJECTIVE—With increasing emphasis on the recognition of the metabolic syndrome and early type 2 diabetes, a clinically useful measure of insulin resistance is desirable. The purpo...
Comparing the caffeine content of caffeine-containing dietary supplements in British Columbia
Comparing the caffeine content of caffeine-containing dietary supplements in British Columbia
Background and Purpose: The use of dietary supplements is on the rise in Canada. This raises questions about the safety of the supplements when taken in the recommended dosage. One...
Does Caffeine Enhance Athletic Performance?
Does Caffeine Enhance Athletic Performance?
Aim: A plethora of studies have been conducted to examine the effect of caffeine on athletic performance, with conflicting results. The purpose of the study is to investigate the e...
Assessment of caffeine consumption behavior among Jazan University students in the south of Saudi Arabia: A cross-sectional study
Assessment of caffeine consumption behavior among Jazan University students in the south of Saudi Arabia: A cross-sectional study
Caffeine is a central nervous system stimulant. High consumption levels of caffeine can lead to intoxication and serious side effects. Saudi Arabia is witnessing a rise in the comm...
Caffeine decreases neuromuscular fatigue in the lumbar muscles – a randomized blind study
Caffeine decreases neuromuscular fatigue in the lumbar muscles – a randomized blind study
ABSTRACTBackgroundErgogenic evidence for caffeine is robust in sports and isolated limb tasks. Our objective was to evaluate a possible ergogenic effect on postural muscles, still ...
Insulin Action During Pregnancy: Studies with the Euglycemic Clamp Technique
Insulin Action During Pregnancy: Studies with the Euglycemic Clamp Technique
To assess the mechanisms responsible for the insulin resistance associated with both normal human pregnancy and gestational-onset diabetes, we have measured exogenous glucose dispo...

Back to Top