Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Fire Risks in Using Paraffin as Neutron Radiation Shielding Material

View through CrossRef
ABSTRACTSafety in general and fire safety in particular are key concerns in neutron‐based research facilities, and the choice of the material that is used to stop neutron radiation is critical in this respect. Borated paraffin has been used at existing research facilities and could potentially be used at new facilities. However, a literature search resulted in very little information about the fire properties of borated paraffin. This was the motivation for the study discussed in this article. Two types of fire tests were performed. The Cone Calorimeter was used to obtain heat release rate characteristics of regular paraffin and borated paraffin. The results from standard Cone Calorimeter tests on specimens in the horizontal orientation show that borated paraffin with 4.5% boron has a heat release rate per unit area that is a factor of 3–5 lower than regular paraffin. The second type of test involved exposure of a small mock‐up of a section of a hollow steel wall filled with borated paraffin exposed on one side to the standard ISO 834 temperature–time curve. During the first 20 min of the test, the borated paraffin in contact with the steel plate on the exposed side melted. Pressure from boiling water in the resulting cavity was relieved by pushing the molten paraffin to the unexposed side, where it exited through cracks in the unexposed surface of the wall section. The test confirmed the hypothesis of pressure release by molten paraffin.
Title: Fire Risks in Using Paraffin as Neutron Radiation Shielding Material
Description:
ABSTRACTSafety in general and fire safety in particular are key concerns in neutron‐based research facilities, and the choice of the material that is used to stop neutron radiation is critical in this respect.
Borated paraffin has been used at existing research facilities and could potentially be used at new facilities.
However, a literature search resulted in very little information about the fire properties of borated paraffin.
This was the motivation for the study discussed in this article.
Two types of fire tests were performed.
The Cone Calorimeter was used to obtain heat release rate characteristics of regular paraffin and borated paraffin.
The results from standard Cone Calorimeter tests on specimens in the horizontal orientation show that borated paraffin with 4.
5% boron has a heat release rate per unit area that is a factor of 3–5 lower than regular paraffin.
The second type of test involved exposure of a small mock‐up of a section of a hollow steel wall filled with borated paraffin exposed on one side to the standard ISO 834 temperature–time curve.
During the first 20 min of the test, the borated paraffin in contact with the steel plate on the exposed side melted.
Pressure from boiling water in the resulting cavity was relieved by pushing the molten paraffin to the unexposed side, where it exited through cracks in the unexposed surface of the wall section.
The test confirmed the hypothesis of pressure release by molten paraffin.

Related Results

A Method for Determining the Porosity of Pulsed Neutron by Combining Gamma Energy and Time Spectrum
A Method for Determining the Porosity of Pulsed Neutron by Combining Gamma Energy and Time Spectrum
Pulsed-neutron gamma energy spectroscopy and neutron lifetime measurement systems enable the evaluation of the elemental content, saturation. And recent studies have demonstrated t...
Simulation of neutron shielding performance of Al-Cd alloy for radioactive waste container
Simulation of neutron shielding performance of Al-Cd alloy for radioactive waste container
Abstract Neutron shielding material is necessary for the container of radioactive waste emitting neutrons, such as spent fuel from research reactor. This study aimed...
Study of coded source neutron imaging based on a compact accelerator
Study of coded source neutron imaging based on a compact accelerator
Compact accelerator based neutron source has lower cost and better flexibility than nuclear reactor. Neutron imaging using such a neutron source has attracted more and more attenti...
Neutron and Photon Dose Rates in a D-T Neutron Generator Facility: MCNP Simulations and Experiments
Neutron and Photon Dose Rates in a D-T Neutron Generator Facility: MCNP Simulations and Experiments
Abstract The deuterium-tritium neutron generator is a common neutron source for fast neutron activation analysis. The 14.1 MeV neutrons emitted from a deuterium-tritium n...
Determination of Coal Ash Content by Neutron-Neutron Logging
Determination of Coal Ash Content by Neutron-Neutron Logging
Abstract The research is aimed at assessing the possibility of studying the ash content of coal seams using neutron-neutron logging in coal exploration wells drilled...
A New Method of Porosity Determination by D-T Neutron Generator and Dual CLYC Detector
A New Method of Porosity Determination by D-T Neutron Generator and Dual CLYC Detector
Porosity is one of the essential parameters in conventional oil and gas reservoir evaluation, as well as plays an important role in the calculation of formation saturation and rese...
EVALUATION OF NEUTRON SHIELDING PERFORMANCE OF CD-SS 316L AS A CANDIDATE ALLOY FOR DRY CASK OF RESEARCH REACTOR SPENT FUEL
EVALUATION OF NEUTRON SHIELDING PERFORMANCE OF CD-SS 316L AS A CANDIDATE ALLOY FOR DRY CASK OF RESEARCH REACTOR SPENT FUEL
EVALUATION OF NEUTRON SHIELDING PERFORMANCE OF CD-SS 316L AS A CANDIDATE ALLOY FOR DRY CASK OF RESEARCH REACTOR SPENT FUEL Development of dry casks is necessary to support the nati...

Back to Top