Uncertainty Evaluations of the CRCS In-orbit Field Radiometric Calibration Methods for Thermal Infrared Channels of FENGYUN Meteorological Satellites

View through CrossRef
<p>Meteorological satellites have become an irreplaceable weather and ocean-observing tool in China. These satellites are used to monitor natural disasters and improve the efficiency of many sectors of Chinese national economy. It is impossible to ignore the space-derived data in the fields of meteorology, hydrology, and agriculture, as well as disaster monitoring in China, a large agricultural country. For this reason, China is making a sustained effort to build and enhance its meteorological observing system and application system. The first Chinese polar-orbiting weather satellite was launched in 1988. Since then China has launched 17 meteorological satellites, 8 of which are sun synchronous and 9 of which are geostationary satellites; China will continue its two types of meteorological satellite programs.</p><p>In order to achieve the in-orbit absolute radiometric calibration of the operational meteorological satellites’ thermal infrared channels, China radiometric calibration sites (CRCS) established a set of in-orbit field absolute radiometric calibration methods (FCM) for thermal infrared channels (TIR) and the uncertainty of this method was evaluated and analyzed based on TERRA/AQUA MODIS observations. Comparisons between the MODIS at pupil brightness temperatures (BTs) and the simulated BTs at the top of atmosphere using radiative transfer model (RTM) based on field measurements showed that the accuracy of the current in-orbit field absolute radiometric calibration methods was better than 1.00K (@300K, K=1) in thermal infrared channels. Therefore, the current CRCS field calibration method for TIR channels applied to Chinese metrological satellites was with favorable calibration accuracy: for 10.5-11.5µm channel was better than 0.75K (@300K, K=1) and for 11.5-12.5µm channel was better than 0.85K (@300K, K=1).</p>
Title: Uncertainty Evaluations of the CRCS In-orbit Field Radiometric Calibration Methods for Thermal Infrared Channels of FENGYUN Meteorological Satellites
Description:
<p>Meteorological satellites have become an irreplaceable weather and ocean-observing tool in China.
These satellites are used to monitor natural disasters and improve the efficiency of many sectors of Chinese national economy.
It is impossible to ignore the space-derived data in the fields of meteorology, hydrology, and agriculture, as well as disaster monitoring in China, a large agricultural country.
For this reason, China is making a sustained effort to build and enhance its meteorological observing system and application system.
The first Chinese polar-orbiting weather satellite was launched in 1988.
Since then China has launched 17 meteorological satellites, 8 of which are sun synchronous and 9 of which are geostationary satellites; China will continue its two types of meteorological satellite programs.
</p><p>In order to achieve the in-orbit absolute radiometric calibration of the operational meteorological satellites’ thermal infrared channels, China radiometric calibration sites (CRCS) established a set of in-orbit field absolute radiometric calibration methods (FCM) for thermal infrared channels (TIR) and the uncertainty of this method was evaluated and analyzed based on TERRA/AQUA MODIS observations.
Comparisons between the MODIS at pupil brightness temperatures (BTs) and the simulated BTs at the top of atmosphere using radiative transfer model (RTM) based on field measurements showed that the accuracy of the current in-orbit field absolute radiometric calibration methods was better than 1.
00K (@300K, K=1) in thermal infrared channels.
Therefore, the current CRCS field calibration method for TIR channels applied to Chinese metrological satellites was with favorable calibration accuracy: for 10.
5-11.
5µm channel was better than 0.
75K (@300K, K=1) and for 11.
5-12.
5µm channel was better than 0.
85K (@300K, K=1).
</p>.

Related Results

(Invited) Strategies for Calibration Cost Reduction in Heterogeneous Chemical Sensor Arrays
(Invited) Strategies for Calibration Cost Reduction in Heterogeneous Chemical Sensor Arrays
Introduction Heterogeneous gas sensor arrays coupled with machine learning algorithms have been proposed for a wide range of applications. However, i...
Low-altitude measurement of CRCS Dunhuang surface reflectance based on multi-rotor electric UAV
Low-altitude measurement of CRCS Dunhuang surface reflectance based on multi-rotor electric UAV
The CRCS Dunhuang site (40.1821°N, 94.3244°E) is located in the Gobi Desert in northwest China, about 35 km west of Dunhuang City, Gansu Province. Covering approx...
Clinicopathological and molecular features of genome-stable colorectal cancers
Clinicopathological and molecular features of genome-stable colorectal cancers
Abstract Colorectal cancers (CRCs) are traditionally divided into CRCs with either chromosomal instability (CIN) or microsatellite instability (MSI). By utilizing TCGA data...
Capacidad de respuesta de la cadena de suministro: definición del concepto y marco para mejorar la gestión
Capacidad de respuesta de la cadena de suministro: definición del concepto y marco para mejorar la gestión
(English) Research on supply chain responsiveness (SCR) is a topic of interest to academics and professionals because it facilitates the fulfillment of customer expectations in an ...
Immunological profiles in Lynch syndrome colorectal cancers are not specific to mismatch repair gene defects
Immunological profiles in Lynch syndrome colorectal cancers are not specific to mismatch repair gene defects
AbstractBackground and aimsColorectal carcinomas (CRCs) in patients with Lynch syndrome (LS) exhibit heightened immunogenicity due to mismatch repair deficiency (MMR-d), often resu...
Colorectal Cancer Screening Among Latinos in Three Communities on the Texas–Mexico Border
Colorectal Cancer Screening Among Latinos in Three Communities on the Texas–Mexico Border
Objective. To assess colorectal cancer screening (CRCS) prevalence and psychosocial correlates of CRCS among Latinos in South Texas. Method. Using multivariable analyses, we examin...
Numerical Analysis of the Influence of Typical Perturbation Forces on LEO Satellites Orbit Prediction at Different Altitudes
Numerical Analysis of the Influence of Typical Perturbation Forces on LEO Satellites Orbit Prediction at Different Altitudes
Aiming at the development of the application of massive and heterogeneous LEO constellations, the influence of typical perturbation forces on the orbit prediction of LEO satellites...
New Perspectives for 3D Visualization of Dynamic Reservoir Uncertainty
New Perspectives for 3D Visualization of Dynamic Reservoir Uncertainty
This reference is for an abstract only. A full paper was not submitted for this conference. Abstract 1 Int...

Back to Top