Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

An Optimization Study of Advanced Fenton Oxidation Methods (UV/Fenton–MW/Fenton) for Treatment of Real Epoxy Paint Wastewater

View through CrossRef
The use of various advanced oxidation methods in the treatment of wastewater has become the subject of many studies published in recent years. In particular, it is exceedingly significant to compare these treatment methods for industrial wastewater to reduce environmental effects and optimize plant operations and economics. The present study is the first to deal with the treatability of real epoxy paint wastewater (EPW) using MW- and UV-assisted Fenton processes within an optimization framework. A three-factor, three-level Box–Behnken experimental design combined with response surface methodology (RSM) was conducted for maximizing the chemical oxygen demand (COD) and color removal efficiencies of ultraviolet (UV)/Fenton and microwave (MW)/Fenton processes in the treatment of the real epoxy paint wastewater (EPW, initial COD = 4600 ± 90 mg/L, initial color = 114 ± 4 Pt-Co), based on 15 different experimental runs. Three independent variables (reaction time ranging from 20 to 60 min (UV) and from 5 to 15 min (MW), power ranging from 20 to 40 W (UV) and from 300 to 600 W (MW), and H2O2/Fe2+ ratio ranging from 0.2 to 0.6 (for both UV and MW)) were consecutively coded as A, B, and C at three levels (−1, 0, and 1), and four second-order polynomial regression equations were then derived to estimate the responses (COD and color removals) of two distinct systems. The significance of the independent model components and their interrelations were appraised by means of a variance analysis with 99% confidence limits (α = 0.01). The standardized differences of the independent variables and the consistency between the actual and predicted values were also investigated by preparing normal probability residual plots and experiment-model plots for all processes. The optimal operating conditions were attained by solving the quadratic regression models and analyzing the surface and contour plots. UV/Fenton and MW/Fenton processes, which constitute combined Fenton processes, were performed using advanced oxidation methods, while Fenton processes were utilized as the standard method for wastewater treatment. When UV/Fenton and MW/Fenton processes were applied separately, the COD removal efficiencies were determined to be 96.4% and 95.3%, respectively. For the color parameter, the removal efficiencies after the application of both processes were found to exceed 97.5%. While these efficiencies were achieved in 1 h with a 38 W UV unit, they were achieved in 15 min with a MW power of 570 W. According to the RSM-based regression analysis results, the R2 values for both processes were greater than 0.97 and p values were less than 0.003.
Title: An Optimization Study of Advanced Fenton Oxidation Methods (UV/Fenton–MW/Fenton) for Treatment of Real Epoxy Paint Wastewater
Description:
The use of various advanced oxidation methods in the treatment of wastewater has become the subject of many studies published in recent years.
In particular, it is exceedingly significant to compare these treatment methods for industrial wastewater to reduce environmental effects and optimize plant operations and economics.
The present study is the first to deal with the treatability of real epoxy paint wastewater (EPW) using MW- and UV-assisted Fenton processes within an optimization framework.
A three-factor, three-level Box–Behnken experimental design combined with response surface methodology (RSM) was conducted for maximizing the chemical oxygen demand (COD) and color removal efficiencies of ultraviolet (UV)/Fenton and microwave (MW)/Fenton processes in the treatment of the real epoxy paint wastewater (EPW, initial COD = 4600 ± 90 mg/L, initial color = 114 ± 4 Pt-Co), based on 15 different experimental runs.
Three independent variables (reaction time ranging from 20 to 60 min (UV) and from 5 to 15 min (MW), power ranging from 20 to 40 W (UV) and from 300 to 600 W (MW), and H2O2/Fe2+ ratio ranging from 0.
2 to 0.
6 (for both UV and MW)) were consecutively coded as A, B, and C at three levels (−1, 0, and 1), and four second-order polynomial regression equations were then derived to estimate the responses (COD and color removals) of two distinct systems.
The significance of the independent model components and their interrelations were appraised by means of a variance analysis with 99% confidence limits (α = 0.
01).
The standardized differences of the independent variables and the consistency between the actual and predicted values were also investigated by preparing normal probability residual plots and experiment-model plots for all processes.
The optimal operating conditions were attained by solving the quadratic regression models and analyzing the surface and contour plots.
UV/Fenton and MW/Fenton processes, which constitute combined Fenton processes, were performed using advanced oxidation methods, while Fenton processes were utilized as the standard method for wastewater treatment.
When UV/Fenton and MW/Fenton processes were applied separately, the COD removal efficiencies were determined to be 96.
4% and 95.
3%, respectively.
For the color parameter, the removal efficiencies after the application of both processes were found to exceed 97.
5%.
While these efficiencies were achieved in 1 h with a 38 W UV unit, they were achieved in 15 min with a MW power of 570 W.
According to the RSM-based regression analysis results, the R2 values for both processes were greater than 0.
97 and p values were less than 0.
003.

Related Results

Cumene hydroperoxide treatment by fenton and electro-fenton process
Cumene hydroperoxide treatment by fenton and electro-fenton process
This research investigated the feasibility of treating phenol-production wastewater by treatment combination among Fenton, electro-Fenton and aerobic biological processes. Wastewat...
Li1.4Al0.4Ti1.6(PO4)3 high lithium ion conducting solid electrolyte prepared by tape casting and modified with epoxy resin
Li1.4Al0.4Ti1.6(PO4)3 high lithium ion conducting solid electrolyte prepared by tape casting and modified with epoxy resin
The Li1.4Al0.4Ti1.6(PO4)3(LATP) nanocrystal powder is synthesized by citric acid assisted sol-gel method.The LATP powder is crystalized at 850℃ for 4 h,and the X-ray diffraction pa...
Atrazine Removal in Municipal Secondary Effluents by Fenton and Photo‐Fenton Treatments
Atrazine Removal in Municipal Secondary Effluents by Fenton and Photo‐Fenton Treatments
AbstractAlternative water sources, including effluents from municipal wastewater treatment plants (MWTP) are necessary to meet increasing water demand. Advanced oxidation processes...
Halloysite Nanotubes Reinforced Epoxy/Epoxy Acrylate Blends: Unlocking the Potential of Hybrid Nanocomposites
Halloysite Nanotubes Reinforced Epoxy/Epoxy Acrylate Blends: Unlocking the Potential of Hybrid Nanocomposites
Unlocking the potential of polymer blends requires innovative strategies that transcend simple mixing. This study presents a novel approach by creating hybrid blends of epoxy and s...
Heterogeneous Fenton - Based Treatment for Petroleum Refinery Wastewater: A Systematic Review
Heterogeneous Fenton - Based Treatment for Petroleum Refinery Wastewater: A Systematic Review
Environmentally friendly methods are recommended for the petroleum refining industries, for treatment of the generated wastewater. Ammonia, sulfides, phenol, oil and grease, and pe...
A Hybrid Photo-Catalytic Approach Utilizing Oleic Acid-Capped ZnO Nanoparticles for the Treatment of Wastewater Containing Reactive Dyes
A Hybrid Photo-Catalytic Approach Utilizing Oleic Acid-Capped ZnO Nanoparticles for the Treatment of Wastewater Containing Reactive Dyes
In pursuit of overcoming Fenton’s oxidation limitations in wastewater treatment, an introduction of heterogeneous photocatalyst is developed. In this regard, the current work is in...
Occurrence and variations of cryptosporidium and giardia in wastewater treatment and receiving river basins
Occurrence and variations of cryptosporidium and giardia in wastewater treatment and receiving river basins
Wastewater disposal may be a source of environmental contamination of Cryptosporidium and Giardia. Releasing untreated wastewater into the environment may result in waterborne or f...
DESAIN ULANG LEMARI MIXING E POXY PADA PT EXCELITAS TECHNOLOGIES BATAM
DESAIN ULANG LEMARI MIXING E POXY PADA PT EXCELITAS TECHNOLOGIES BATAM
PT Excelitas is a company located in the batamindo area that produces light detectors or often called sensors. However, even though the excelitas company has made efforts to run an...

Back to Top