Javascript must be enabled to continue!
Henning Devices: A New Class of VIV Suppression Apparatus for Offshore Tubulars
View through CrossRef
Abstract
This paper introduces a new class of vortex-induced vibration (VIV) suppression apparatus, Henning devices. Test results for a number of such devices are presented and discussed. One of the main advantages of these novel devices over helical strakes and streamlined fairings is that the coverage density required to be effective is reduced from about 70 to 80% or more to approximately 20 to 25%. The drag on the tubulars with the light coverage density is therefore significantly reduced, compared to that of helical strakes. An additional advantage of Henning devices over fairings is that they are not required to rotate to be effective at reducing VIV, as evidenced by the tests. With the application of this new type of hardware, great cost savings can be expected.
Introduction
Offshore tubulars used in oil and gas exploration and production are often protected from vortex-induced vibration (VIV) with add-on hardware. Among the various types of suppression devices, helical strakes and streamlined fairings are the most common. These apparatus are effective at reducing VIV, though each has its own advantages and disadvantages [1,2]. One common feature to strakes and fairings is that a coverage density of greater than 70 to 80% is normally required to effectively mitigate VIV [3]. For example, if a suppression coverage length of 1,000 ft of the tubular is determined necessary, the required amount of suppression, in linear feet, should be at least 700 to 800 ft spaced evenly along the 1000 ft length.
Extensive VIV testing has been performed at Shell Westhollow Technology Center current tank, to explore more efficient suppression devices. As a result, a new class of VIV suppression hardware was discovered in 2006. In early 2007, a general methodology for VIV suppression was developed based upon the understanding of the test results. Additional tests, at higher Reynolds number, were subsequently conducted to further validate these novel concepts.
This paper presents and discusses some of the test results for this new class of suppression devices. First, the test facility and setup are described, followed by an introduction of various types of Henning devices. Test results for three examples (tribladed, square, and fixed 4-bladed devices in a range of applications) are presented next to illustrate various features. Conclusions are drawn thereafter.
The information presented in this paper should be of interest to offshore engineers and project managers involved in platform, mooring and riser design as well as project execution, as it discusses some of the latest developments in VIV suppression.
Title: Henning Devices: A New Class of VIV Suppression Apparatus for Offshore Tubulars
Description:
Abstract
This paper introduces a new class of vortex-induced vibration (VIV) suppression apparatus, Henning devices.
Test results for a number of such devices are presented and discussed.
One of the main advantages of these novel devices over helical strakes and streamlined fairings is that the coverage density required to be effective is reduced from about 70 to 80% or more to approximately 20 to 25%.
The drag on the tubulars with the light coverage density is therefore significantly reduced, compared to that of helical strakes.
An additional advantage of Henning devices over fairings is that they are not required to rotate to be effective at reducing VIV, as evidenced by the tests.
With the application of this new type of hardware, great cost savings can be expected.
Introduction
Offshore tubulars used in oil and gas exploration and production are often protected from vortex-induced vibration (VIV) with add-on hardware.
Among the various types of suppression devices, helical strakes and streamlined fairings are the most common.
These apparatus are effective at reducing VIV, though each has its own advantages and disadvantages [1,2].
One common feature to strakes and fairings is that a coverage density of greater than 70 to 80% is normally required to effectively mitigate VIV [3].
For example, if a suppression coverage length of 1,000 ft of the tubular is determined necessary, the required amount of suppression, in linear feet, should be at least 700 to 800 ft spaced evenly along the 1000 ft length.
Extensive VIV testing has been performed at Shell Westhollow Technology Center current tank, to explore more efficient suppression devices.
As a result, a new class of VIV suppression hardware was discovered in 2006.
In early 2007, a general methodology for VIV suppression was developed based upon the understanding of the test results.
Additional tests, at higher Reynolds number, were subsequently conducted to further validate these novel concepts.
This paper presents and discusses some of the test results for this new class of suppression devices.
First, the test facility and setup are described, followed by an introduction of various types of Henning devices.
Test results for three examples (tribladed, square, and fixed 4-bladed devices in a range of applications) are presented next to illustrate various features.
Conclusions are drawn thereafter.
The information presented in this paper should be of interest to offshore engineers and project managers involved in platform, mooring and riser design as well as project execution, as it discusses some of the latest developments in VIV suppression.
Related Results
Pragmatic Riser VIV Analysis
Pragmatic Riser VIV Analysis
Abstract
Drilling and production risers experiencing vortex-induced vibrations (VIV) may adversely impact operations in two ways: by increasing deflection due to ...
Benchmarking Bayesian methods for spectroscopy
Benchmarking Bayesian methods for spectroscopy
<p class="p1"><span class="s1"><strong>Introduction:</strong></span>&l...
Consistent VIV Fatigue Analysis Methodology of Umbilicals
Consistent VIV Fatigue Analysis Methodology of Umbilicals
The fatigue life assessment of umbilicals due to vortex induced vibrations (VIV) requires special attention to the structural properties of the umbilical due to the stick/slip beha...
Modeling VIV Supression Using Negative Lift Coefficients
Modeling VIV Supression Using Negative Lift Coefficients
Vortex-Induced Vibration (VIV) is a complex, non-linear fluid-structure interaction problem with important consequences for offshore risers, tendons and other tubulars. The prevale...
Fuze Well Mechanical Interface
Fuze Well Mechanical Interface
<div class="section abstract">
<div class="htmlview paragraph">This interface standard applies to fuzes used in airborne weapons that use a 3-Inch Fuze Well. It defin...
Alternative Offshore Foundation Installation Methods
Alternative Offshore Foundation Installation Methods
Abstract
According to the European Wind Energy Association (EWEA) in the first six months of 2012, Europe installed and fully grid connected 132 offshore wind tur...
High Mode Number Vortex-Induced Vibration Field Experiments
High Mode Number Vortex-Induced Vibration Field Experiments
Abstract
This paper presents the initial results from VIV (Vortex-Induced Vibration) field testing of a long, flexible, model riser at high mode number. The exper...
Cybersecurity Guidebook for Cyber-Physical Vehicle Systems
Cybersecurity Guidebook for Cyber-Physical Vehicle Systems
<div class="section abstract">
<div class="htmlview paragraph">This recommended practice provides guidance on vehicle Cybersecurity and was created based off of, and ...