Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Biomechanical testing of osteosynthetic locking plates for proximal humeral shaft fractures – a systematic literature review

View through CrossRef
Abstract Proximal humeral shaft fractures can be treated with helically deformed bone plates to reduce the risk of iatrogenic nerve lesion. Controversially to this common surgical technique that was first established in 1999, no biomechanical investigation on humeral helical plating is recorded by other reviews, which focus on proximal fractures exclusively. Does an additional scope for shaft fractures reveal findings of helical testing? The present systematic literature review was performed based on guidelines by Kitchenham et al. to systematically search and synthesize literature regarding biomechanical testing of osteosynthetic systems for proximal humeral shaft fractures. Therefore, a systematic approach to search and screen literature was defined beforehand and applied on the findings of the database PubMed®. Synthesized information of the included literature was categorized, summarized and analyzed via descriptive statistics. Out of 192 findings, 22 publications were included for qualitative synthesis. A wide range of different test methods was identified, leading to a suboptimal comparability of specific results between studies. Overall, 54 biomechanical test scenarios were identified and compared. Physiological based boundary conditions (PB-BC) were referenced in 7 publications only. One study of testing straight and helical dynamic compression plates without PB-BCs was identified, showing significant differences under compressional loading. The absence of test standards of specific fields like humeral fractures lead to a high variance in biomechanical testing of osteosynthetic locking plates for proximal humeral shaft fractures. Physiological approaches offer realistic test scenarios but need to be uniformed for enhanced comparability between studies. The impact of helically deformed locking plates under PB-BC was not identified in literature.
Title: Biomechanical testing of osteosynthetic locking plates for proximal humeral shaft fractures – a systematic literature review
Description:
Abstract Proximal humeral shaft fractures can be treated with helically deformed bone plates to reduce the risk of iatrogenic nerve lesion.
Controversially to this common surgical technique that was first established in 1999, no biomechanical investigation on humeral helical plating is recorded by other reviews, which focus on proximal fractures exclusively.
Does an additional scope for shaft fractures reveal findings of helical testing? The present systematic literature review was performed based on guidelines by Kitchenham et al.
to systematically search and synthesize literature regarding biomechanical testing of osteosynthetic systems for proximal humeral shaft fractures.
Therefore, a systematic approach to search and screen literature was defined beforehand and applied on the findings of the database PubMed®.
Synthesized information of the included literature was categorized, summarized and analyzed via descriptive statistics.
Out of 192 findings, 22 publications were included for qualitative synthesis.
A wide range of different test methods was identified, leading to a suboptimal comparability of specific results between studies.
Overall, 54 biomechanical test scenarios were identified and compared.
Physiological based boundary conditions (PB-BC) were referenced in 7 publications only.
One study of testing straight and helical dynamic compression plates without PB-BCs was identified, showing significant differences under compressional loading.
The absence of test standards of specific fields like humeral fractures lead to a high variance in biomechanical testing of osteosynthetic locking plates for proximal humeral shaft fractures.
Physiological approaches offer realistic test scenarios but need to be uniformed for enhanced comparability between studies.
The impact of helically deformed locking plates under PB-BC was not identified in literature.

Related Results

Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Abstract The Physical Activity Guidelines for Americans (Guidelines) advises older adults to be as active as possible. Yet, despite the well documented benefits of physical activi...
The Epidemiology of Infant Shaft Fractures of Femur or Humerus by Incidence, Birth, Accidents, and Other Causes
The Epidemiology of Infant Shaft Fractures of Femur or Humerus by Incidence, Birth, Accidents, and Other Causes
Abstract Background: Knowledge of femur and humerus shaft fractures during infancy is scarce. The purpose of this population-based registry study was to analyze both birth-...
Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
Treatment of fractures of the proximal end and humeral shaft by locked intramedullary nailing in adults: Case series and literature review
Treatment of fractures of the proximal end and humeral shaft by locked intramedullary nailing in adults: Case series and literature review
Introduction: Intramedullary nailing is a good indication for stabilizing displaced fractures of the proximal end and shaft of the humerus in adults. Methods: This was a prospectiv...
Asymptomatic Osteonecrosis of the Trochlea in an Adolescent: A Case Report
Asymptomatic Osteonecrosis of the Trochlea in an Adolescent: A Case Report
Abstract Introduction Osteonecrosis, also known as avascular necrosis, aseptic necrosis, or ischemic necrosis, results from a temporary or permanent halt in blood flow to a portion...
Periprosthetic Humeral Fractures in Shoulder Arthroplasty
Periprosthetic Humeral Fractures in Shoulder Arthroplasty
» The reported combined rates of intraoperative and postoperative periprosthetic humeral fractures range widely, from 1.2% to 19.4%. ...

Back to Top