Javascript must be enabled to continue!
Mobile Robot Gas Source Localization Using SLAM-GDM with a Graphene-Based Gas Sensor
View through CrossRef
Mobile olfaction is one of the applications of mobile robots. Metal oxide sensors (MOX) are mobile robots’ most popular gas sensors. However, the sensor has drawbacks, such as high-power consumption, high operating temperature, and long recovery time. This research compares a reduced graphene oxide (RGO) sensor with the traditionally used MOX in a mobile robot. The method uses a map created from simultaneous localization and mapping (SLAM) combined with gas distribution mapping (GDM) to draw the gas distribution in the map and locate the gas source. RGO and MOX are tested in the lab for their response to 100 and 300 ppm ethanol. Both sensors’ response and recovery times show that RGO resulted in 56% and 54% faster response times, with 33% and 57% shorter recovery times than MOX. In the experiment, one gas source, 95% ethanol solution, is placed in the lab, and the mobile robot runs through the map in 7 min and 12 min after the source is set, with five repetitions. The results show the average distance error of the predicted source from the actual location was 19.52 cm and 30.28 cm using MOX and 25.24 cm and 30.60 cm using the RGO gas sensor for the 7th and 12th min trials, respectively. The errors show that the predicted gas source location based on MOX is 1.0% (12th min), much closer to the actual site than that predicted with RGO. However, RGO also shows a larger gas sensing area than MOX by 0.35–8.33% based on the binary image of the SLAM-GDM map, which indicates that RGO is much more sensitive than MOX in the trial run. Regarding power consumption, RGO consumes an average of 294.605 mW, 56.33% less than MOX, with an average consumption of 674.565 mW. The experiment shows that RGO can perform as well as MOX in mobile olfaction applications but with lower power consumption and operating temperature.
Title: Mobile Robot Gas Source Localization Using SLAM-GDM with a Graphene-Based Gas Sensor
Description:
Mobile olfaction is one of the applications of mobile robots.
Metal oxide sensors (MOX) are mobile robots’ most popular gas sensors.
However, the sensor has drawbacks, such as high-power consumption, high operating temperature, and long recovery time.
This research compares a reduced graphene oxide (RGO) sensor with the traditionally used MOX in a mobile robot.
The method uses a map created from simultaneous localization and mapping (SLAM) combined with gas distribution mapping (GDM) to draw the gas distribution in the map and locate the gas source.
RGO and MOX are tested in the lab for their response to 100 and 300 ppm ethanol.
Both sensors’ response and recovery times show that RGO resulted in 56% and 54% faster response times, with 33% and 57% shorter recovery times than MOX.
In the experiment, one gas source, 95% ethanol solution, is placed in the lab, and the mobile robot runs through the map in 7 min and 12 min after the source is set, with five repetitions.
The results show the average distance error of the predicted source from the actual location was 19.
52 cm and 30.
28 cm using MOX and 25.
24 cm and 30.
60 cm using the RGO gas sensor for the 7th and 12th min trials, respectively.
The errors show that the predicted gas source location based on MOX is 1.
0% (12th min), much closer to the actual site than that predicted with RGO.
However, RGO also shows a larger gas sensing area than MOX by 0.
35–8.
33% based on the binary image of the SLAM-GDM map, which indicates that RGO is much more sensitive than MOX in the trial run.
Regarding power consumption, RGO consumes an average of 294.
605 mW, 56.
33% less than MOX, with an average consumption of 674.
565 mW.
The experiment shows that RGO can perform as well as MOX in mobile olfaction applications but with lower power consumption and operating temperature.
Related Results
Information metrics for localization and mapping
Information metrics for localization and mapping
Decades of research have made possible the existence of several autonomous systems that successfully and efficiently navigate within a variety of environments under certain conditi...
Comparing the first trimester and second trimester fifty grams oral glucose tolerance test values in gestational diabetes mellitus
Comparing the first trimester and second trimester fifty grams oral glucose tolerance test values in gestational diabetes mellitus
Objective: The present study aimed to assess the results of pregnant women who have been applied a 50 g oral glucose tolerance test (OGTT) in the first and second trimesters and in...
Pregnancy and Challenging Transient Anti-GAD65 Positivity: A Case Report with Literature Review
Pregnancy and Challenging Transient Anti-GAD65 Positivity: A Case Report with Literature Review
Abstract
Introduction
During pregnancy, women may develop blood glucose abnormalities like gestational diabetes mellitus (GDM) or, rarely, type 1 diabetes (T1D), which can lead to ...
Mild Gestational Diabetes and Adverse Pregnancy Outcome: A Systemic Review and Meta-Analysis
Mild Gestational Diabetes and Adverse Pregnancy Outcome: A Systemic Review and Meta-Analysis
Background and Objectives: Mild gestational diabetes (GDM) refers to the gestational hyperglycemia, which does not fulfill the diagnostic criteria for GDM. The results of studies o...
Sistem Kendali Hybrid Fuzzy-Pid pada Kinematika Robot Berkaki 4 Menggunakan Sensor Gyroscope
Sistem Kendali Hybrid Fuzzy-Pid pada Kinematika Robot Berkaki 4 Menggunakan Sensor Gyroscope
<p><em>Legged robots have attracted the attention of researchers because of their superior adaptation to complex environments compared to wheeled robots. Legged robots ...
325-OR: Gestational Diabetes Mellitus (GDM) Is Associated with Higher Fat Mass (FM) Accretion in Male Infants during Early Postnatal Period
325-OR: Gestational Diabetes Mellitus (GDM) Is Associated with Higher Fat Mass (FM) Accretion in Male Infants during Early Postnatal Period
Introduction and Objective: Infants of women with GDM can exhibit higher FM accretion in the early postnatal period, but sex-specific trajectories of FM and fat-free mass (FFM) rem...
Sensor Gas Amonia Berbasis Polimer Konduktif Polianilina: Sebuah Review
Sensor Gas Amonia Berbasis Polimer Konduktif Polianilina: Sebuah Review
Artikel review ini memberikan informasi tentang aplikasi polianilina (PANI) dan kompositnya sebagai sensor gas berbahaya khususnya amonia (NH3). Kajian yang dibahas pada artikel in...
Dynamic stochastic modeling for inertial sensors
Dynamic stochastic modeling for inertial sensors
Es ampliamente conocido que los modelos de error para sensores inerciales tienen dos componentes: El primero es un componente determinista que normalmente es calibrado por el fabri...

