Online Optimal Ventilation Control of Building Air-conditioning Systems

View through CrossRef
This paper presents a ventilation control strategy for multi-zone variable air volume (VAV) air-conditioning systems; integrating the sequential split-range control strategy for air-handing units with an aim to optimise the fresh air flow rate by compromising the indoor air quality and energy consumption. In this strategy, a CO2 -based adaptive demand-controlled ventilation scheme would employ a dynamic multi-zone ventilation equation for multi-zone air-conditioning systems, in which a CO2-based dynamic occupancy detection scheme would be used for online occupancy detection. The strategy would identify the critical zones online, and fully consider the outdoor air demand of critical zones, while, a model-based fresh air flow rate optimal control scheme is employed for VAV air-conditioning systems with the primary air handling units. An adaptive optimisation algorithm would be used for optimising the fresh air flow rate to minimise the energy consumption. The energy saving potentials in the Hong Kong climate condition by optimising fresh air ventilation and the practical implementation of the control strategy are also discussed in this paper.
Title: Online Optimal Ventilation Control of Building Air-conditioning Systems
Description:
This paper presents a ventilation control strategy for multi-zone variable air volume (VAV) air-conditioning systems; integrating the sequential split-range control strategy for air-handing units with an aim to optimise the fresh air flow rate by compromising the indoor air quality and energy consumption.
In this strategy, a CO2 -based adaptive demand-controlled ventilation scheme would employ a dynamic multi-zone ventilation equation for multi-zone air-conditioning systems, in which a CO2-based dynamic occupancy detection scheme would be used for online occupancy detection.
The strategy would identify the critical zones online, and fully consider the outdoor air demand of critical zones, while, a model-based fresh air flow rate optimal control scheme is employed for VAV air-conditioning systems with the primary air handling units.
An adaptive optimisation algorithm would be used for optimising the fresh air flow rate to minimise the energy consumption.
The energy saving potentials in the Hong Kong climate condition by optimising fresh air ventilation and the practical implementation of the control strategy are also discussed in this paper.

Related Results

Ventilation in university classrooms during the COVID-19 pandemic
Ventilation in university classrooms during the COVID-19 pandemic
The Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) virus has caused a pandemic, forcing schools and universities to stop in-person classes. For universities to allow ...
Analysis on The Risk of Respiratory Virus Transmission By Air Conditioning System Operation-Based on Experimental Evidence
Analysis on The Risk of Respiratory Virus Transmission By Air Conditioning System Operation-Based on Experimental Evidence
Abstract It is important to know whether SARS-CoV-2 is spread through the air-conditioning systems. Taking the central air-conditioning system as an example, we analyze the...
RESULTS OF NUMERICAL SIMULATION OF GEOTHERMAL COOLING IN THE VENTILATION SYSTEM OF ANIMAL PREMISES
RESULTS OF NUMERICAL SIMULATION OF GEOTHERMAL COOLING IN THE VENTILATION SYSTEM OF ANIMAL PREMISES
The microclimate of livestock premises is determined by a set of physical, chemical and biological parameters inside the premises for keeping animals and is characterized by the fo...
Energy efficient ventilation strategies for surgery rooms
Energy efficient ventilation strategies for surgery rooms
Surgery rooms are a space type with particularly stringent indoor environmental quality (IEQ) requirements, which translate into high energy use. Due to the unclear IEQ and infecti...
Neural substrates underlying human delay and trace eyeblink conditioning
Neural substrates underlying human delay and trace eyeblink conditioning
Classical conditioning paradigms, such as trace conditioning, in which a silent period elapses between the offset of the conditioned stimulus (CS) and the delivery of the unconditi...
Episodic ventilation lowers the efficiency of pulmonary CO2excretion
Episodic ventilation lowers the efficiency of pulmonary CO2excretion
The ventilation pattern of many ectothermic vertebrates, as well as hibernating and diving endotherms, is episodic where breaths are clustered in bouts interspersed among apneas of...
[RETRACTED] Optimal Max Keto - Does It ReallyWork? v1
[RETRACTED] Optimal Max Keto - Does It ReallyWork? v1
[RETRACTED]Shedding the unwanted weight and controlling the calories of your body is the most challenging and complicated process. As we start aging, we have to deal with lots of...
Indoor Air Quality in Public Health Centers: A Case Study of Public Health Centers Located on Main and Secondary Roadsides, Bangkok
Indoor Air Quality in Public Health Centers: A Case Study of Public Health Centers Located on Main and Secondary Roadsides, Bangkok
This cross-sectional study investigated the indoor air quality (IAQ) of public health centers (PHCs) and primary health care units in Bangkok to determine the impact of the differe...