Javascript must be enabled to continue!
Impact of physical properties and accumulation rate on pore close-off in layered firn
View through CrossRef
Abstract. Investigations into the physical characteristics of deep firn near the lock-in zone through pore close-off are needed to improve understanding of ice core records of past atmospheric composition. Specifically, the permeability and microstructure profiles of the firn through the diffusive column influence the entrapment of air into bubbles and thus the ice age–gas age difference. The purpose of this study is to examine the nature of pore closure processes at two polar sites with very different local temperatures and accumulation rates. Density, permeability, and microstructure measurements were made on firn cores from the West Antarctic Ice Sheet (WAIS) Divide, a site that has moderate accumulation rates with a seasonal climate archive, and Megadunes in East Antarctica, a site that is a natural laboratory for accumulation rate effects in the cold low-accumulation desert. We found that the open pore structure plays a more important role than density in predicting gas transport properties, throughout the porous firn matrix. For firn below 50 m depth at both WAIS Divide and Megadunes, finer-grained layers experience close-off shallower in the firn column than do coarser-grained layers, regardless of which grain size layer is the denser layer at depth. Pore close-off occurs at a critical open porosity that is accumulation rate dependent. Defining pore close-off at a critical open porosity for a given accumulation rate as opposed to a critical total porosity accounts for the pore space available for gas transport. Below the critical open porosity, the firn becomes impermeable despite having small amounts of interconnected pore space. The low-accumulation sites, with generally coarse grains, close off at lower open porosities (~<10%) than the open porosity (~>10%) of high-accumulation sites that have generally finer grains. The microstructure and permeability even near the bottom of the firn column are relic indicators of the nature of accumulation when that firn was at the surface. The physical structure and layering are the primary controlling factors on pore close-off. In contrast to current assumptions for polar firn, the depth and length of the lock-in zone is primarily dependent upon accumulation rate and microstructural variability due to differences in grain size and pore structure, rather than the density variability of the layers.
Title: Impact of physical properties and accumulation rate on pore close-off in layered firn
Description:
Abstract.
Investigations into the physical characteristics of deep firn near the lock-in zone through pore close-off are needed to improve understanding of ice core records of past atmospheric composition.
Specifically, the permeability and microstructure profiles of the firn through the diffusive column influence the entrapment of air into bubbles and thus the ice age–gas age difference.
The purpose of this study is to examine the nature of pore closure processes at two polar sites with very different local temperatures and accumulation rates.
Density, permeability, and microstructure measurements were made on firn cores from the West Antarctic Ice Sheet (WAIS) Divide, a site that has moderate accumulation rates with a seasonal climate archive, and Megadunes in East Antarctica, a site that is a natural laboratory for accumulation rate effects in the cold low-accumulation desert.
We found that the open pore structure plays a more important role than density in predicting gas transport properties, throughout the porous firn matrix.
For firn below 50 m depth at both WAIS Divide and Megadunes, finer-grained layers experience close-off shallower in the firn column than do coarser-grained layers, regardless of which grain size layer is the denser layer at depth.
Pore close-off occurs at a critical open porosity that is accumulation rate dependent.
Defining pore close-off at a critical open porosity for a given accumulation rate as opposed to a critical total porosity accounts for the pore space available for gas transport.
Below the critical open porosity, the firn becomes impermeable despite having small amounts of interconnected pore space.
The low-accumulation sites, with generally coarse grains, close off at lower open porosities (~<10%) than the open porosity (~>10%) of high-accumulation sites that have generally finer grains.
The microstructure and permeability even near the bottom of the firn column are relic indicators of the nature of accumulation when that firn was at the surface.
The physical structure and layering are the primary controlling factors on pore close-off.
In contrast to current assumptions for polar firn, the depth and length of the lock-in zone is primarily dependent upon accumulation rate and microstructural variability due to differences in grain size and pore structure, rather than the density variability of the layers.
Related Results
Changing glacier firn in Central Asia and its impact on glacier mass balance
Changing glacier firn in Central Asia and its impact on glacier mass balance
Glaciers in the Central Asian mountain ranges Tien Shan, Pamir and Pamir Alay are important water reservoirs for the dry low lands. These mountain glaciers attracted scientific int...
Impact of climate forcing time step on the modelled ice-sheet firn layer
Impact of climate forcing time step on the modelled ice-sheet firn layer
Abstract. The firn layer regulates how an ice-sheet responds to climate change by modifying how changes in surface temperature, snow accumulation and ablation affect the ice-sheet ...
Improved modelling of the present-day Greenland firn layer
Improved modelling of the present-day Greenland firn layer
<p>Recent studies indicate that a declining surface mass balance will dominate the Greenland Ice Sheet&#8217;s (GrIS) contribution to 21<sup>st&...
A Physics-based Framework to Infer Firn Properties on Antarctic Ice Shelves from ASCAT Observations
A Physics-based Framework to Infer Firn Properties on Antarctic Ice Shelves from ASCAT Observations
Abstract. The stability of Antarctic ice shelves is closely linked to the properties of the firn layer, which regulates meltwater retention and influences ice shelf vulnerability t...
Spatial response of Greenland’s firn layer to NAO variability
Spatial response of Greenland’s firn layer to NAO variability
Changes in the Greenland ice sheet (GrIS) firn layer may impact its ability to retain meltwater. These changes also need to be accounted for when converting measured ice sheet volu...
Antarctic firn air content depletion for different climate change scenarios
Antarctic firn air content depletion for different climate change scenarios
Firn covers about 99% of the Antarctic ice sheet, providing, among other things, pore space in which most of the surface meltwater refreezes. Under antic...
Evolution of the Antarctic firn layer until 2100 under two climate change scenarios. 
Evolution of the Antarctic firn layer until 2100 under two climate change scenarios. 
<p>Firn covers ~99% of the Antarctic ice sheet, providing pore space in which nearly all of the surface meltwater refreezes or is retained in liquid form. For now, th...
Climate forcing time step requirements for firn modeling
Climate forcing time step requirements for firn modeling
The firn layer regulates how an ice sheet responds to climate change, by modifying how changes in surface temperature, snow accumulation and ablation affects the ice sheet mass bal...

