Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Quantification of the Plasma Concentrations of Perampanel Using High-Performance Liquid Chromatography and Effects of the CYP3A4*1G Polymorphism in Japanese Patients

View through CrossRef
Abstract Here, we developed a novel high-performance liquid chromatography (HPLC) method for quantification of perampanel in clinical practice and investigated the relationships between the plasma concentrations of perampanel obtained by this HPLC method and the CYP3A4*1G polymorphism. The developed HPLC method was validated based on US Food and Drug Administration. The developed HPLC method could be performed with a plasma volume of only 200 μL and had a limit of quantification (LOQ) of 2.5 ng/mL. The coefficients of variation (CVs) for intra- and inter-day assays were less than 10.4 and 7.2%, respectively, and the accuracy was <2.4% for both assays. A total of 12 patients who received 2 mg perampanel had C0 values ranging from 70.5 to 451 ng/mL, and the CV showed a large variation of 51.4%. No correlations were observed between the dose-adjusted C0 and the CYP3A4*1G polymorphism. This method was superior to previously reported methods in terms of plasma volume and LOQ and was clinically applicable. Perampanel showed high variations in individual plasma concentrations; however, individual differences could not be predicted from analysis of the CYP3A4*1G polymorphism before perampanel administration. Therefore, after beginning perampanel treatment, the dose should be determined based on the observed plasma concentration.
Title: Quantification of the Plasma Concentrations of Perampanel Using High-Performance Liquid Chromatography and Effects of the CYP3A4*1G Polymorphism in Japanese Patients
Description:
Abstract Here, we developed a novel high-performance liquid chromatography (HPLC) method for quantification of perampanel in clinical practice and investigated the relationships between the plasma concentrations of perampanel obtained by this HPLC method and the CYP3A4*1G polymorphism.
The developed HPLC method was validated based on US Food and Drug Administration.
The developed HPLC method could be performed with a plasma volume of only 200 μL and had a limit of quantification (LOQ) of 2.
5 ng/mL.
The coefficients of variation (CVs) for intra- and inter-day assays were less than 10.
4 and 7.
2%, respectively, and the accuracy was <2.
4% for both assays.
A total of 12 patients who received 2 mg perampanel had C0 values ranging from 70.
5 to 451 ng/mL, and the CV showed a large variation of 51.
4%.
No correlations were observed between the dose-adjusted C0 and the CYP3A4*1G polymorphism.
This method was superior to previously reported methods in terms of plasma volume and LOQ and was clinically applicable.
Perampanel showed high variations in individual plasma concentrations; however, individual differences could not be predicted from analysis of the CYP3A4*1G polymorphism before perampanel administration.
Therefore, after beginning perampanel treatment, the dose should be determined based on the observed plasma concentration.

Related Results

A post hoc analysis of the long‐term safety and efficacy of perampanel in Asian patients with epilepsy
A post hoc analysis of the long‐term safety and efficacy of perampanel in Asian patients with epilepsy
SummaryThis post hoc analysis assessed the long‐term safety, tolerability, and efficacy of perampanel in Asian patients with refractory focal seizures; an additional analysis asses...
Review of clinical studies of perampanel in adolescent patients
Review of clinical studies of perampanel in adolescent patients
AbstractAimTo assess the clinical trial and real‐world data for adjunctive perampanel in adolescents and develop consensus recommendations to guide the use of perampanel in this po...
CYP3A Genotypes in Bangladeshi Tuberculosis Patients
CYP3A Genotypes in Bangladeshi Tuberculosis Patients
The purpose of this study is to investigate the genotype and allelic frequencies of CYP3A in Bangladeshi Tuberculosis (TB) patients which may help for individualized drug dosing an...
Perampanel Mitigates Neuroinflammation and Nitrosative Stress in a Rat Model of Traumatic Brain Injury
Perampanel Mitigates Neuroinflammation and Nitrosative Stress in a Rat Model of Traumatic Brain Injury
Abstract Traumatic brain injury (TBI) is a common cause of disability and mortality across all age groups. Inflammation is a crucial contributor to secondary injury followi...
Zero to hero
Zero to hero
Western images of Japan tell a seemingly incongruous story of love, sex and marriage – one full of contradictions and conflicting moral codes. We sometimes hear intriguing stories ...
Magnetohydrodynamics enhanced radio blackout mitigation system for spacecraft during planetary entries
Magnetohydrodynamics enhanced radio blackout mitigation system for spacecraft during planetary entries
(English) Spacecraft entering planetary atmospheres are enveloped by a plasma layer with high levels of ionization, caused by the extreme temperatures in the shock layer. The charg...
CYP3A4 and CYP11A1 Variants are Risk Factors for Ischemic Stroke: a Case Control Study
CYP3A4 and CYP11A1 Variants are Risk Factors for Ischemic Stroke: a Case Control Study
Abstract Background This study aimed to investigate the roles of CYP3A4 and CYP11A1 variants in ischemic stroke (IS) susceptibility among the Han Chinese population. Meth...
Usefulness of saliva for perampanel therapeutic drug monitoring
Usefulness of saliva for perampanel therapeutic drug monitoring
AbstractObjectiveTherapeutic drug monitoring (TDM) of antiepileptic drugs (AEDs) helps optimize drug management for patients with epilepsy. Salivary testing is both noninvasive and...

Back to Top