Retrofitting of a High-Rise Residential Building for Energy Efficiency with OTTV as an Assessment Tool

View through CrossRef
Buildings account for nearly 50% of the total energy consumption. The use of air-conditioning is one of the major influencers to the high energy consumption in buildings. To tackle this high energy consumption, buildings are required to be more energy efficient. This study aimed to investigate the retrofitting of existing residential building for energy efficiency by using the Overall Thermal Transfer Value (OTTV) as an assessment tool. Various retrofitting measures were involved, including varying the colour of the opaque wall with different solar absorptivity, the U-value and shading coefficient of the Glazing system, and the type and projection of the external shading. The results showed that applying the retrofitting measures individually (i.e., using light colour with low solar absorptivity, replacing the glazing system to have lower shading coefficient and U-value, and the installation of external shading systems with low shading coefficient) can decrease the OTTV by 26% to 33.4%. However, combining these measures managed to decrease the OTTV by up to 75.6% (i.e., the OTTV decreased from 82.87 W/m² to 20.19 W/m²). This can improve the building energy efficiency as it contributes to less cooling load for the air-conditioned buildings, while it provides a better indoor environment in non-air-conditioned buildings.
Title: Retrofitting of a High-Rise Residential Building for Energy Efficiency with OTTV as an Assessment Tool
Description:
Buildings account for nearly 50% of the total energy consumption.
The use of air-conditioning is one of the major influencers to the high energy consumption in buildings.
To tackle this high energy consumption, buildings are required to be more energy efficient.
This study aimed to investigate the retrofitting of existing residential building for energy efficiency by using the Overall Thermal Transfer Value (OTTV) as an assessment tool.
Various retrofitting measures were involved, including varying the colour of the opaque wall with different solar absorptivity, the U-value and shading coefficient of the Glazing system, and the type and projection of the external shading.
The results showed that applying the retrofitting measures individually (i.
e.
, using light colour with low solar absorptivity, replacing the glazing system to have lower shading coefficient and U-value, and the installation of external shading systems with low shading coefficient) can decrease the OTTV by 26% to 33.
4%.
However, combining these measures managed to decrease the OTTV by up to 75.
6% (i.
e.
, the OTTV decreased from 82.
87 W/m² to 20.
19 W/m²).
This can improve the building energy efficiency as it contributes to less cooling load for the air-conditioned buildings, while it provides a better indoor environment in non-air-conditioned buildings.

Related Results

OTTV'S Assessment on Thermal Performance of High-Rise Apartment Buildings in Penang
OTTV'S Assessment on Thermal Performance of High-Rise Apartment Buildings in Penang
This study evaluates the envelope thermal performance of high-rise apartment buildings in Malaysia, which are being largely dominated due to the high economic development and incre...
ANALYSIS OF THERMAL TRANSFER VALUES IN TEACHING CLASSROOMS
ANALYSIS OF THERMAL TRANSFER VALUES IN TEACHING CLASSROOMS
Erratic weather, such as intense heat followed by heavy rain, is causing air pollution in the sky of Jakarta. According to the SNI 03-6389-2011, which deals with energy conservatio...
Optimising tool wear and workpiece condition monitoring via cyber-physical systems for smart manufacturing
Optimising tool wear and workpiece condition monitoring via cyber-physical systems for smart manufacturing
Smart manufacturing has been developed since the introduction of Industry 4.0. It consists of resource sharing and networking, predictive engineering, and material and data analyti...
Retrofitting an Existing Office Building in the UAE Towards Achieving Low-Energy Building
Retrofitting an Existing Office Building in the UAE Towards Achieving Low-Energy Building
Retrofitting an existing building can oftentimes be more cost-effective than building a new facility. Since buildings consume a significant amount of energy, particularly for heati...
Analysis of Hotel Façade Thermal Performance with a Special Reference to the City Hotels in George Town, Penang
Analysis of Hotel Façade Thermal Performance with a Special Reference to the City Hotels in George Town, Penang
The present study identifies issues pertaining energy efficiency of high-rise city hotels in Malaysia and aims to examine the thermal performance of high-rise hotels with different...
Embodied Carbon in Australian Residential Houses: A Preliminary Study
Embodied Carbon in Australian Residential Houses: A Preliminary Study
Embodied carbon is a buzzword in the construction industry. Australia is committed to achieving Net Zero 2050 targets, and minimizing embodied carbon (EC) is inevitable. Owing to t...
Der skal ikke lades sten på sten tilbage
Der skal ikke lades sten på sten tilbage
The Building by the Barbar TempleClose by the large temple at Barbar 1) lies a little tell, which was investigated in the spring of 1956. The tell was shown to cover a building of ...