Javascript must be enabled to continue!
In vitro biodegradation behavior of biodegradable hydroxyapatite coated AZ31 alloy treated at various pH values
View through CrossRef
Objectives:
The aim of this study is to evaluate the effect of pH treatment on the formation of hydroxyapatite (HA) coating layer and the biodegradation rate of hydroxyapatite coated AZ31 alloy for applications in biodegradable implants.
Methods:
HA was grown on the surface of AZ31 substrate at three different pH solutions of 7.5, 9.0, and 10.5 respectively by chemical solution treatment method. The coated samples were evaluated their biodegradation behavior by immersion test in the simulated body fluid (SBF) for 14 days. The biodegradation rate of the samples during immersion test was observed by Mg
2+
ion quantification method and measuring the increase of pH of the medium.
Results:
HA coatings were successfully grown on the AZ31 substrate at three different pH conditions. The sample coated at pH 7.5 showed its uniform and dense coating layer resulted in highest corrosion resistance. While the highest biodegradation rate was observed for the sample coated at pH 10.5 due to many micro-cracks formed in the HA layer. After 14 days of immersion, Mg(OH)
2
and calcium phosphate were corrosion products on the surface of the specimens coated at pH 10.5 and pH 9.0 respectively. While HA almost remained on the surface of sample coated at pH 7.5.
Conclusion:
AZ31 alloy coated with HA at pH 7.5 has lowest biodegradation rate and become suitable for applications in biodegradable implants.
Title: In vitro biodegradation behavior of biodegradable hydroxyapatite coated AZ31 alloy treated at various pH values
Description:
Objectives:
The aim of this study is to evaluate the effect of pH treatment on the formation of hydroxyapatite (HA) coating layer and the biodegradation rate of hydroxyapatite coated AZ31 alloy for applications in biodegradable implants.
Methods:
HA was grown on the surface of AZ31 substrate at three different pH solutions of 7.
5, 9.
0, and 10.
5 respectively by chemical solution treatment method.
The coated samples were evaluated their biodegradation behavior by immersion test in the simulated body fluid (SBF) for 14 days.
The biodegradation rate of the samples during immersion test was observed by Mg
2+
ion quantification method and measuring the increase of pH of the medium.
Results:
HA coatings were successfully grown on the AZ31 substrate at three different pH conditions.
The sample coated at pH 7.
5 showed its uniform and dense coating layer resulted in highest corrosion resistance.
While the highest biodegradation rate was observed for the sample coated at pH 10.
5 due to many micro-cracks formed in the HA layer.
After 14 days of immersion, Mg(OH)
2
and calcium phosphate were corrosion products on the surface of the specimens coated at pH 10.
5 and pH 9.
0 respectively.
While HA almost remained on the surface of sample coated at pH 7.
5.
Conclusion:
AZ31 alloy coated with HA at pH 7.
5 has lowest biodegradation rate and become suitable for applications in biodegradable implants.
Related Results
Enhanced osteoconductivity of sodium‐substituted hydroxyapatite by system instability
Enhanced osteoconductivity of sodium‐substituted hydroxyapatite by system instability
AbstractThe effect of substituting sodium for calcium on enhanced osteoconductivity of hydroxyapatite was newly investigated. Sodium‐substituted hydroxyapatite was synthesized by r...
Synthesis and Investigation into Apatite-forming Ability of Hydroxyapatite/Chitosan-based Scaffold
Synthesis and Investigation into Apatite-forming Ability of Hydroxyapatite/Chitosan-based Scaffold
In this study, porous scaffolds were fabricated using inorganic material-hydroxyapatite and chitosan for bone-tissue engineering. The combination of hydroxyapatite and chitosan may...
Shear Damage Suppression Model of Magnesium Alloy Plates
Shear Damage Suppression Model of Magnesium Alloy Plates
Abstract
By shearing Q235 steel, aluminum, and AZ31 magnesium alloy at room temperature, the shear area of Q235 steel and aluminum is found to be relatively flat whereas th...
Bio-Resorption Control and Biological Response of Magnesium Alloy AZ31 Coated with Poly-β-hydroxybutyrate
Bio-Resorption Control and Biological Response of Magnesium Alloy AZ31 Coated with Poly-β-hydroxybutyrate
Magnesium and its alloys are not normally used as bio-resorbable temporary implants due to their high and uncontrolled degradation rate in physiological liquid environment. The imp...
Study on damping capacity of graphite particle—reinforced AZ31 magnesium matrix composites
Study on damping capacity of graphite particle—reinforced AZ31 magnesium matrix composites
The damping capacities of 1%, 5%, and 9% (by mass) graphite particle—reinforced AZ31 magnesium matrix (Grp/AZ31) composites and unreinforced AZ31 magnesium alloy in as-annealed and...
Biodegradation of polycyclic aromatic hydrocarbons in the surface ocean
Biodegradation of polycyclic aromatic hydrocarbons in the surface ocean
Increasing quantities of organic pollutants (OP) are being released to the environment, posing a threat to Earth’s life system. In the marine environment, OP pollution caused by oi...
Removal of Cadmium Ions from Aqueous Solution by Silicate‐incorporated Hydroxyapatite
Removal of Cadmium Ions from Aqueous Solution by Silicate‐incorporated Hydroxyapatite
Abstract: This article reports a preliminary research on silicate‐incorporated hydroxyapatite as a new environmental mineral used to remove cadmium ions from aqueous solutions. The...
In Vitro Comparative Study of Fretting-Corrosion Resistance of Ti6Al4V and Co28Cr6Mo in a Taper Joint Subjected to High Bending Moment
In Vitro Comparative Study of Fretting-Corrosion Resistance of Ti6Al4V and Co28Cr6Mo in a Taper Joint Subjected to High Bending Moment
Co alloy modular necks have been introduced in orthopaedics to address mechanical failure of the neck-stem junction (NSJ) observed in Ti alloy dual-modular hip stem. However, follo...

