The Effect of Drive Signals on Output Performance of Piezoelectric Pumps

View through CrossRef
The output performance of piezoelectric pumps is not only affected by the structural design but is also related to the drive signal. To study the effect of different drive signals on the output performance of piezoelectric pumps, this paper takes dual-chamber serial piezoelectric pumps as the investigation object, theoretically deduces the effective value of the drive signal and the output performance of the piezoelectric pump, and tests the displacement of piezoelectric vibrator center, the output performance of the piezoelectric pump, and the operating noise within the range of 0–500 Hz, respectively, driven by square waves, sine waves, and triangular waves (the peak-to-peak values of which are all 300 V). The results show that at low frequencies, the piezoelectric vibrator’s center displacement curve matches the drive signal, which is sinusoidal and decreases with frequency. Under the square drive, the piezoelectric pump has the best performance, with a flow of 147.199 mL/min and pressure of 14.42 kPa, but the noise is also the highest. The output performance of the sine wave is better than that of the triangular wave, and the flow rate of the three signals shows a trend of first increasing and then decreasing.
Title: The Effect of Drive Signals on Output Performance of Piezoelectric Pumps
Description:
The output performance of piezoelectric pumps is not only affected by the structural design but is also related to the drive signal.
To study the effect of different drive signals on the output performance of piezoelectric pumps, this paper takes dual-chamber serial piezoelectric pumps as the investigation object, theoretically deduces the effective value of the drive signal and the output performance of the piezoelectric pump, and tests the displacement of piezoelectric vibrator center, the output performance of the piezoelectric pump, and the operating noise within the range of 0–500 Hz, respectively, driven by square waves, sine waves, and triangular waves (the peak-to-peak values of which are all 300 V).
The results show that at low frequencies, the piezoelectric vibrator’s center displacement curve matches the drive signal, which is sinusoidal and decreases with frequency.
Under the square drive, the piezoelectric pump has the best performance, with a flow of 147.
199 mL/min and pressure of 14.
42 kPa, but the noise is also the highest.
The output performance of the sine wave is better than that of the triangular wave, and the flow rate of the three signals shows a trend of first increasing and then decreasing.

Related Results

A Constitutive Model for Piezoelectric Paint with Mixed Connectivity
A Constitutive Model for Piezoelectric Paint with Mixed Connectivity
This article presents a constitutive model for piezoelectric paint that addresses its special characteristics such as mixed connectivity and air void content. Piezoelectric paint i...
Review of high temperature piezoelectric materials, devices, and applications
Review of high temperature piezoelectric materials, devices, and applications
Piezoelectric functional materials have been extensively studied and employed in numerous devices. With the rapid development of modern industries, such as power plants, aerospace,...
Design and test of liquid sloshing piezoelectric energy harvester
Design and test of liquid sloshing piezoelectric energy harvester
The energy harvester based on the piezoelectric effect can convert the vibration energy in the environment into electricity to power the network nodes. In order to broaden the effe...
Modelling of the Coupled Beam-Piezoelectric Material With Hysteresis Non-Linerity Effect
Modelling of the Coupled Beam-Piezoelectric Material With Hysteresis Non-Linerity Effect
Hysteresis is one of the non-linearity characteristics of the piezoelectric material. This characteristic is important to be characterized since it can affect the performance of th...
Performance analysis of the functionally graded flexoelectric-piezoelectric energy harvesting
Performance analysis of the functionally graded flexoelectric-piezoelectric energy harvesting
In the present paper, the output performances of the functionally graded flexoelectric-piezoelectric (FGFP) energy harvesting subjected to an external harmonic excitation, consider...
Design and Performance Test of Four-Chamber Series–Parallel Piezoelectric Pump
Design and Performance Test of Four-Chamber Series–Parallel Piezoelectric Pump
In order to improve the output performance of multi-chamber piezoelectric pumps, this paper proposes a novel design for a four-chamber series–parallel piezoelectric pump, based on ...
Integrated switchable ventricular assist devices for pediatric patients
Integrated switchable ventricular assist devices for pediatric patients
Thousands of children are born each year with significant cardiac defects that result in the development of heart disease and ultimately premature congestive heart failure (CHF). I...