Micropulse Transscleral Cyclophotocoagulation: Our Experience

View through CrossRef
Introduction Traditionally, ciliary body destruction has been used to treat uncontrolled intraocular pressure (IOP) following maximally tolerable medical therapy. This is due to the large number of complications seen with this procedure. However, recently a new technique of sub-threshold laser or micropulse laser, is able to provide selective destruction of the ciliary body in a controlled manner. This avoids most of the complications seen with other modalities. We have performed a small case descriptive pilot study to assess the effectiveness of micropulse transscleral cyclophotocoagulation (MP-TSCPC) in lowering IOP. Methods This pilot study was conducted on four patients in the age range 55-70-years with intractable glaucoma. Two patients had primary angle closure glaucoma, one-each had steroid-induced glaucoma and neovascular glaucoma. Mean baseline IOP was 32±2.4 mmHg. Mean number of glaucoma medications were 2.5±1.5. All patients underwent 180° MP-TSCPC. Absolute success was defined as IOP<20 mmHg without acetazolamide. Results Following the procedure the patients were followed-up at days 1,7,30 and 90. At the last follow-up of the study, mean IOP was 18.2±1.2 mmHg in all four patients. Mild anterior chamber inflammation was the only complication noted. Mean number of glaucoma medications reduced to 1.5±1.0 following the procedure. Thus, absolute success was achieved in all patients. Conclusion This small pilot study validates other studies which show effectiveness of MP-TSCPC as an efficient and safe procedure to lower IOP. This procedure can be used over a wide variety of cases, though the indications for such procedures are still evolving. More extensive and long-term studies will clarify the position of this procedure in our glaucoma management practices.
Title: Micropulse Transscleral Cyclophotocoagulation: Our Experience
Description:
Introduction Traditionally, ciliary body destruction has been used to treat uncontrolled intraocular pressure (IOP) following maximally tolerable medical therapy.
This is due to the large number of complications seen with this procedure.
However, recently a new technique of sub-threshold laser or micropulse laser, is able to provide selective destruction of the ciliary body in a controlled manner.
This avoids most of the complications seen with other modalities.
We have performed a small case descriptive pilot study to assess the effectiveness of micropulse transscleral cyclophotocoagulation (MP-TSCPC) in lowering IOP.
Methods This pilot study was conducted on four patients in the age range 55-70-years with intractable glaucoma.
Two patients had primary angle closure glaucoma, one-each had steroid-induced glaucoma and neovascular glaucoma.
Mean baseline IOP was 32±2.
4 mmHg.
Mean number of glaucoma medications were 2.
5±1.
5.
All patients underwent 180° MP-TSCPC.
Absolute success was defined as IOP<20 mmHg without acetazolamide.
Results Following the procedure the patients were followed-up at days 1,7,30 and 90.
At the last follow-up of the study, mean IOP was 18.
2±1.
2 mmHg in all four patients.
Mild anterior chamber inflammation was the only complication noted.
Mean number of glaucoma medications reduced to 1.
5±1.
0 following the procedure.
Thus, absolute success was achieved in all patients.
Conclusion This small pilot study validates other studies which show effectiveness of MP-TSCPC as an efficient and safe procedure to lower IOP.
This procedure can be used over a wide variety of cases, though the indications for such procedures are still evolving.
More extensive and long-term studies will clarify the position of this procedure in our glaucoma management practices.

Related Results

Micropulse transscleral cyclophotocoagulation in glaucoma treatment: 2 years of observations
Micropulse transscleral cyclophotocoagulation in glaucoma treatment: 2 years of observations
Abstract Purpose. To evaluate the results of micropulse cyclophotocoagulation in patients with primary open-angle refractory glaucoma (POAG) and neovascular glaucoma over a 2-...
Result of Micropulse Transscleral Cyclophotocoagulation (MP-TSCPC) as Treatment Modality of Refractory Glaucoma
Result of Micropulse Transscleral Cyclophotocoagulation (MP-TSCPC) as Treatment Modality of Refractory Glaucoma
Background: Refractory glaucoma remains a significant therapeutic challenge due to its resistance to conventional pharmacologic and surgical interventions. Recent advancements such...
Efficacy and Safety of Repeated Micropulse Transscleral Diode Cyclophotocoagulation in Advanced Glaucoma
Efficacy and Safety of Repeated Micropulse Transscleral Diode Cyclophotocoagulation in Advanced Glaucoma
Precis: Repeat micropulse transscleral cyclophotocoagulation (MPTCP) has some benefit in lowering intraocular pressure (IOP). There was a small risk of loss of vision, ...
Clinical Efficacy and Safety Outcomes of Micropulse Transscleral Diode Cyclophotocoagulation in Patients With Advanced Glaucoma
Clinical Efficacy and Safety Outcomes of Micropulse Transscleral Diode Cyclophotocoagulation in Patients With Advanced Glaucoma
Precis: Micropulse transscleral cyclophotocoagulation (MPTCP) is only moderately effective in lowering intraocular pressure (IOP) and is useful as an adjunct procedure ...
Micropulse Transscleral Cyclophotocoagulation Results in Secondary Glaucoma
Micropulse Transscleral Cyclophotocoagulation Results in Secondary Glaucoma
The aim of this study was to analyze the long-term outcome of first session of micropulse transscleral cyclophotocoagulation (MP-CPC) for refractory glaucoma developed after vitreo...
MicroPulse Transscleral Diode: An Effective Non-Surgical Treatment Alternate for Glaucoma
MicroPulse Transscleral Diode: An Effective Non-Surgical Treatment Alternate for Glaucoma
Aim: To determine the efficacy and safety of MicroPulse transscleral laser therapy (MP-TLT) in different types of glaucoma. Study design: Interventional case series. Duration and S...
Different techniques in transscleral cyclophotocoagulation
Different techniques in transscleral cyclophotocoagulation
Transscleral cyclophotocoagulation (TSCPC) is a minimally invasive laser procedure used to reduce intraocular pressure in patients with glaucoma. By selectively coagulating the cil...
Cyclodiode vs micropulse transscleral laser treatment
Cyclodiode vs micropulse transscleral laser treatment
AbstractPurpose: Continuous wave transscleral cyclophotocoagulation (CW‐TSCPC), is reserved for refractory glaucoma with poor visual potential due to its complication rate, attribu...

Back to Top