Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Dynamic cone-beam CT reconstruction using spatial and temporal implicit neural representation learning (STINR)

View through CrossRef
Abstract Objective . Dynamic cone-beam CT (CBCT) imaging is highly desired in image-guided radiation therapy to provide volumetric images with high spatial and temporal resolutions to enable applications including tumor motion tracking/prediction and intra-delivery dose calculation/accumulation. However, dynamic CBCT reconstruction is a substantially challenging spatiotemporal inverse problem, due to the extremely limited projection sample available for each CBCT reconstruction (one projection for one CBCT volume). Approach . We developed a simultaneous spatial and temporal implicit neural representation (STINR) method for dynamic CBCT reconstruction. STINR mapped the unknown image and the evolution of its motion into spatial and temporal multi-layer perceptrons (MLPs), and iteratively optimized the neuron weightings of the MLPs via acquired projections to represent the dynamic CBCT series. In addition to the MLPs, we also introduced prior knowledge, in the form of principal component analysis (PCA)-based patient-specific motion models, to reduce the complexity of the temporal mapping to address the ill-conditioned dynamic CBCT reconstruction problem. We used the extended-cardiac-torso (XCAT) phantom and a patient 4D-CBCT dataset to simulate different lung motion scenarios to evaluate STINR. The scenarios contain motion variations including motion baseline shifts, motion amplitude/frequency variations, and motion non-periodicity. The XCAT scenarios also contain inter-scan anatomical variations including tumor shrinkage and tumor position change. Main results . STINR shows consistently higher image reconstruction and motion tracking accuracy than a traditional PCA-based method and a polynomial-fitting-based neural representation method. STINR tracks the lung target to an average center-of-mass error of 1–2 mm, with corresponding relative errors of reconstructed dynamic CBCTs around 10%. Significance . STINR offers a general framework allowing accurate dynamic CBCT reconstruction for image-guided radiotherapy. It is a one-shot learning method that does not rely on pre-training and is not susceptible to generalizability issues. It also allows natural super-resolution. It can be readily applied to other imaging modalities as well.
Title: Dynamic cone-beam CT reconstruction using spatial and temporal implicit neural representation learning (STINR)
Description:
Abstract Objective .
Dynamic cone-beam CT (CBCT) imaging is highly desired in image-guided radiation therapy to provide volumetric images with high spatial and temporal resolutions to enable applications including tumor motion tracking/prediction and intra-delivery dose calculation/accumulation.
However, dynamic CBCT reconstruction is a substantially challenging spatiotemporal inverse problem, due to the extremely limited projection sample available for each CBCT reconstruction (one projection for one CBCT volume).
Approach .
We developed a simultaneous spatial and temporal implicit neural representation (STINR) method for dynamic CBCT reconstruction.
STINR mapped the unknown image and the evolution of its motion into spatial and temporal multi-layer perceptrons (MLPs), and iteratively optimized the neuron weightings of the MLPs via acquired projections to represent the dynamic CBCT series.
In addition to the MLPs, we also introduced prior knowledge, in the form of principal component analysis (PCA)-based patient-specific motion models, to reduce the complexity of the temporal mapping to address the ill-conditioned dynamic CBCT reconstruction problem.
We used the extended-cardiac-torso (XCAT) phantom and a patient 4D-CBCT dataset to simulate different lung motion scenarios to evaluate STINR.
The scenarios contain motion variations including motion baseline shifts, motion amplitude/frequency variations, and motion non-periodicity.
The XCAT scenarios also contain inter-scan anatomical variations including tumor shrinkage and tumor position change.
Main results .
STINR shows consistently higher image reconstruction and motion tracking accuracy than a traditional PCA-based method and a polynomial-fitting-based neural representation method.
STINR tracks the lung target to an average center-of-mass error of 1–2 mm, with corresponding relative errors of reconstructed dynamic CBCTs around 10%.
Significance .
STINR offers a general framework allowing accurate dynamic CBCT reconstruction for image-guided radiotherapy.
It is a one-shot learning method that does not rely on pre-training and is not susceptible to generalizability issues.
It also allows natural super-resolution.
It can be readily applied to other imaging modalities as well.

Related Results

CREATING LEARNING MEDIA IN TEACHING ENGLISH AT SMP MUHAMMADIYAH 2 PAGELARAN ACADEMIC YEAR 2020/2021
CREATING LEARNING MEDIA IN TEACHING ENGLISH AT SMP MUHAMMADIYAH 2 PAGELARAN ACADEMIC YEAR 2020/2021
The pandemic Covid-19 currently demands teachers to be able to use technology in teaching and learning process. But in reality there are still many teachers who have not been able ...
Near Real-Time X-Ray Cone-Beam Microtomography
Near Real-Time X-Ray Cone-Beam Microtomography
Abstract Due to the penetration ability and absorption contrast mechanism, cone-beam X-ray microtomography is a powerful tool in studying 3D microstructures in opaqu...
Role of the Frontal Lobes in the Propagation of Mesial Temporal Lobe Seizures
Role of the Frontal Lobes in the Propagation of Mesial Temporal Lobe Seizures
Summary: The depth ictal electroencephalographic (EEG) propagation sequence accompanying 78 complex partial seizures of mesial temporal origin was reviewed in 24 patients (15 from...
Implicit Versus Explicit Timing – Separate or Shared Mechanisms?
Implicit Versus Explicit Timing – Separate or Shared Mechanisms?
A bstract Time implicitly shapes cognition, but time is also explicitly represented, for instance in the form of durations. Parsi...
A filtered backprojection algorithm for cone beam reconstructionusing rotational filtering under helical source trajectory
A filtered backprojection algorithm for cone beam reconstructionusing rotational filtering under helical source trajectory
With the evolution from multi‐detector‐row CT to cone beam (CB) volumetric CT, maintaining reconstruction accuracy becomes more challenging. To combat the severe artifacts caused b...
Vævning over gruber
Vævning over gruber
Pits, Looms, and Loom Pits? In the archaeological quarterly Skalk (1959, no 2), Mogens Ørsnes described "The Problem of the Hundred Holes," pits "large and small, shallow and deep"...
Effects of width and density of supersonic molecule beam on penetration depth of tokamak
Effects of width and density of supersonic molecule beam on penetration depth of tokamak
The penetration depth and the fueling efficiency of the supersonic molecular beam injection (SMBI) are affected by both the intrinsic parameters of the SMBI and the parameters of b...

Back to Top