Javascript must be enabled to continue!
Resolving Spatial Conformations of Immuno-Proteins with Cryo-Atomic Force Microscopy (Cryo-Afm)
View through CrossRef
Abstract
A major advantage of atomic force microscopy (AFM) is its intrinsic high contrast, owing to its extremely high sensitivity to height variations. For clean, flat specimens, high-resolution images of a variety of bio-molecules have been obtained, demonstrating the usefulness of AFM in structural biology. However, for large molecular complexes, the effectiveness of AFM is seriously limited, partly owing to the excessive deformation induced by the probe force exerted on the specimen. To overcome this difficulty, we have developed a cryo-AFM, operated under liquid nitrogen vapor at a temperature only a few degrees above 77K. In this system, specimen or tip contamination is significantly reduced, and the resolution achieved with isolated macromolecules is generally higher than that obtainable at room temperature with AFM. Therefore, cryo-AFM has been proven to be a worthy alternative for conventional electron microscopy (EM) with the potential of higher resolution without image averaging.
A particularly fruitful application of cryo-AFM is the study of the spatial structure of several immuno-proteins, where the 3D surface topology of the molecule has been obtained.
Title: Resolving Spatial Conformations of Immuno-Proteins with Cryo-Atomic Force Microscopy (Cryo-Afm)
Description:
Abstract
A major advantage of atomic force microscopy (AFM) is its intrinsic high contrast, owing to its extremely high sensitivity to height variations.
For clean, flat specimens, high-resolution images of a variety of bio-molecules have been obtained, demonstrating the usefulness of AFM in structural biology.
However, for large molecular complexes, the effectiveness of AFM is seriously limited, partly owing to the excessive deformation induced by the probe force exerted on the specimen.
To overcome this difficulty, we have developed a cryo-AFM, operated under liquid nitrogen vapor at a temperature only a few degrees above 77K.
In this system, specimen or tip contamination is significantly reduced, and the resolution achieved with isolated macromolecules is generally higher than that obtainable at room temperature with AFM.
Therefore, cryo-AFM has been proven to be a worthy alternative for conventional electron microscopy (EM) with the potential of higher resolution without image averaging.
A particularly fruitful application of cryo-AFM is the study of the spatial structure of several immuno-proteins, where the 3D surface topology of the molecule has been obtained.
Related Results
Cryo-Expansion Microscopy of C. elegans and Tardigrades v1
Cryo-Expansion Microscopy of C. elegans and Tardigrades v1
Expansion microscopy (ExM) improves imaging resolution through sample-level physical expansion, complementing optical resolution improvements and enabling the two to compound (1). ...
Super‐resolution fluorescence microscopy of cryo‐immobilized samples
Super‐resolution fluorescence microscopy of cryo‐immobilized samples
Correlative light and electron microscopy (CLEM) benefits greatly from the development of super‐resolution fluorescence microscopy. With a resolution down to the 10 nm range it ena...
Atomic electron tomography: 3D structures without crystals
Atomic electron tomography: 3D structures without crystals
BACKGROUND
To understand material properties and functionality at the most fundamental level, one must know the three-dimensional (3D) positions of atoms with h...
Flexible Fitting of Biomolecular Structures to Atomic Force Microscopy Images via Biased Molecular Simulations
Flexible Fitting of Biomolecular Structures to Atomic Force Microscopy Images via Biased Molecular Simulations
Abstract
Atomic force microscopy (AFM) is a prominent imaging technology that observes large-scale structural dynamics of biomolecules near the physiological condit...
NanoLocz: Image Analysis Platform for AFM, High‐Speed AFM, and Localization AFM
NanoLocz: Image Analysis Platform for AFM, High‐Speed AFM, and Localization AFM
AbstractAtomic Force Microscopy (AFM), High‐Speed AFM (HS‐AFM) simulation AFM, and Localization AFM (LAFM) enable the study of molecules and surfaces with increasingly higher spati...
Rigid-body fitting to atomic force microscopy images for inferring probe shape and biomolecular structure
Rigid-body fitting to atomic force microscopy images for inferring probe shape and biomolecular structure
Abstract
Atomic force microscopy (AFM) can visualize functional biomolecules near the physiological condition, but the observed data are limited ...
Development of Fluorescent Markers for Super-Resolution Microscopy at Cryogenic Temperature
Development of Fluorescent Markers for Super-Resolution Microscopy at Cryogenic Temperature
Développement de marqueurs fluorescents pour la microscopie super-résolution à température cryogénique
Single-molecule localization microscopy is a powerful tool fo...
Effects of Atomic Arrangement at Tip Apex and Tip-Sample Distance on Atomic Force Microscopy Images: A Simulation Study
Effects of Atomic Arrangement at Tip Apex and Tip-Sample Distance on Atomic Force Microscopy Images: A Simulation Study
Using a newly developed atomic force microscopy (AFM) simulator ACCESS (AFM simulation code for calculating and evaluating surface structures), effects of the atomic arrangement at...

